High pressure torsion induced lowering of Young's modulus in high strength TNZT alloy for bio-implant applications

被引:28
作者
Maity, T. [1 ,2 ,3 ]
Balci, O. [4 ]
Gammer, C. [3 ]
Ivanov, E. [5 ]
Eckert, J. [2 ,3 ]
Prashanth, K. G. [3 ,6 ,7 ]
机构
[1] Natl Inst Foundry & Forge Technol, Ranchi 834003, Bihar, India
[2] Univ Leoben, Dept Mat Sci, Jahnstr 12, A-8700 Leoben, Austria
[3] Austrian Acad Sci, Erich Schmid Inst Mat Sci, Jahnstr 12, A-8700 Leoben, Austria
[4] Koc Univ, Dept Chem, Rumelifeneri Yolu, Istanbul 34450, Turkey
[5] Tosoh SMD Inc, Grove City, OH 43123 USA
[6] Tallinn Univ Technol, Dept Mech & Ind Engn, Ehitajate Tee 5, EE-19086 Tallinn, Estonia
[7] VIT Univ, Sch Mech Engn, CBCMT, Vellore 632014, Tamil Nadu, India
关键词
beta-Ti alloy; Micro-/nanoindentation; High-pressure torsion; Strain-rate sensitivity; Activation volume; Young's modulus; STRAIN-RATE SENSITIVITY; BETA-TITANIUM ALLOYS; DEFORMATION MECHANISMS; WEAR PROPERTIES; GRAIN-SIZE; NANOCRYSTALLINE; BEHAVIOR; TI; MICROSTRUCTURE; PLASTICITY;
D O I
10.1016/j.jmbbm.2020.103839
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
An exceptional combination of low Young's modulus (E similar to 68 GPa) and high flow strength (sigma(f) similar to 1 GPa) was achieved for a consolidated beta-Ti-based metastable Ti-35Nb-7Zr-5Ta (TNZT) alloy subjected to room temperature high-pressure torsion (HPT). The mechanical properties of the alloy were studied by quasistatic nanoindentation tests at different strain rates, where a reduction in Young's modulus E similar to 73 GPa (N-HPT(10)) and E similar to 68 GPa (N-HPT(40)) is observed together with an increase in plastic deformability (or HPT rotations). The microstructure evolution with increasing shear strain has been investigated. The stabilized bcc beta-Ti phase with homogeneous nanostructure distribution was observed leading to a low Young's modulus. Severe straining causes a uniform hardness distribution without any noticeable change in the strength of the material. This study may be useful for developing excellent removable implant materials.
引用
收藏
页数:10
相关论文
共 41 条
[22]
Development of new metallic alloys for biomedical applications [J].
Niinomi, Mitsuo ;
Nakai, Masaaki ;
Hieda, Junko .
ACTA BIOMATERIALIA, 2012, 8 (11) :3888-3903
[23]
High strength beta titanium alloys: New design approach [J].
Okulov, I. V. ;
Wendrock, H. ;
Volegov, A. S. ;
Attar, H. ;
Kuehn, U. ;
Skrotzki, W. ;
Eckert, J. .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2015, 628 :297-302
[24]
AN IMPROVED TECHNIQUE FOR DETERMINING HARDNESS AND ELASTIC-MODULUS USING LOAD AND DISPLACEMENT SENSING INDENTATION EXPERIMENTS [J].
OLIVER, WC ;
PHARR, GM .
JOURNAL OF MATERIALS RESEARCH, 1992, 7 (06) :1564-1583
[25]
Phase transformations in Ti-35Nb-7Zr-5Ta-(0.06-0.68)O alloys [J].
Qazi, JI ;
Marquardt, B ;
Allard, LF ;
Rack, HJ .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2005, 25 (03) :389-397
[26]
Theory-guided bottom-up design of β-titanium alloys as biomaterials based on first principles calculations:: Theory and experiments [J].
Raabe, D. ;
Sander, B. ;
Friak, M. ;
Ma, D. ;
Neugebauer, J. .
ACTA MATERIALIA, 2007, 55 (13) :4475-4487
[27]
HRTEM analysis of nanostructured alloys processed by severe plastic deformation [J].
Rentenberger, C ;
Waitz, T ;
Karnthaler, HP .
SCRIPTA MATERIALIA, 2004, 51 (08) :789-794
[28]
Selective Laser Melting of Ti-45Nb Alloy [J].
Schwab, Holger ;
Prashanth, Konda Gokuldoss ;
Loeber, Lukas ;
Kuehn, Uta ;
Eckert, Juergen .
METALS, 2015, 5 (02) :686-694
[29]
On the homogeneity of deformation by high pressure torsion [J].
Vorhauer, A ;
Pippan, R .
SCRIPTA MATERIALIA, 2004, 51 (09) :921-925
[30]
Effect of low-temperature rolling on the tensile behavior of commercially pure tungsten [J].
Wei, Q. ;
Kecskes, L. J. .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2008, 491 (1-2) :62-69