Stationary phase retention in CCC: Modelling the J-type centrifuge as a constant pressure drop pump

被引:47
作者
Wood, PL [1 ]
Hawes, D [1 ]
Janaway, L [1 ]
Sutherland, IA [1 ]
机构
[1] Brunel Univ, Brunel Inst Bioengn, Uxbridge UB8 3PH, Middx, England
关键词
countercurrent chromatography; theory; J-type centrifuge; liquid stationary phase retention; constant pressure drop pump; Archimedean forces; density difference;
D O I
10.1081/JLC-120021256
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To be able to design a J-type centrifuge for a given need, a method of being able to predict peak elution is required. Predicting peak elution will also allow the user to optimise the process parameters for his or her needs. Such predictions require an accurate knowledge of the volume of the stationary phase retained in the coil for a given set of operating conditions. This paper builds upon an experimental relationship in that the stationary phase retention decreases proportionally to the square root of the mobile phase flow rate. Combining this experimental relationship with the hypothesis that the pressure drop across a coil is independent of mobile phase flow rate, and assuming that the mobile phase flow is laminar, the equation below is derived: S-f = 100 -800/d(C)(2) root2mu(m)L/piDeltaP rootF Experimental evidence is presented supporting the above equation. The experimental evidence was gained using, a heptane-ethyl acetate-methanol-water (1.4:0.1:0.5: 1) v/v phase system, in normal phase mode using three helical stainless steel coils. These stationary phase retention studies allowed the above equation to be tested under conditions of different rotational speeds and tubing internal diameter. The derived stationary phase retention characteristics from each retention study allowed pressure drop and Reynolds number data to be calculated. The pressure drop data shows that the pressure drop across a coil is constant and independent of the mobile phase flow rate.
引用
收藏
页码:1373 / 1396
页数:24
相关论文
共 14 条
[1]   Test to evaluate countercurrent chromatographs - Liquid stationary phase retention and chromatographic resolution [J].
Berthod, A ;
Billardello, B .
JOURNAL OF CHROMATOGRAPHY A, 2000, 902 (02) :323-335
[2]  
Conway WD., 1990, COUNTERCURRENT CHROM
[3]   Relationship between the flow-rate of the mobile phase and retention of the stationary phase in counter-current chromatography [J].
Du, QZ ;
Wu, CJ ;
Qian, GJ ;
Wu, PD ;
Ito, Y .
JOURNAL OF CHROMATOGRAPHY A, 1999, 835 (1-2) :231-235
[4]  
MASSEY BS, 1989, MECH FLUIDS, P34280
[5]  
*RAIN INSTR CO INC, 1982, PB96 RAIN INSTR CO I
[6]   A new hypothesis on phase distribution in countercurrent chromatography [J].
Sutherland, IA ;
Muytjens, J ;
Prins, M ;
Wood, P .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2000, 23 (15) :2259-2276
[7]   Countercurrent chromatography (CCC) and its versatile application as an industrial purification & production process [J].
Sutherland, IA ;
Brown, L ;
Forbes, S ;
Games, G ;
Hawes, D ;
Hostettmann, K ;
McKerrell, EH ;
Marston, A ;
Wheatley, D ;
Wood, P .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1998, 21 (03) :279-298
[8]   The relationship between retention, linear flow, and density difference in countercurrent chromatography [J].
Sutherland, IA ;
Du, Q ;
Wood, P .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2001, 24 (11-12) :1669-1683
[9]   Industrial scale-up of countercurrent chromatography [J].
Sutherland, IA ;
Booth, AJ ;
Brown, L ;
Kemp, B ;
Kidwell, H ;
Games, D ;
Graham, AS ;
Guillon, GG ;
Hawes, D ;
Hayes, M ;
Janaway, L ;
Lye, GJ ;
Massey, P ;
Preston, C ;
Shering, P ;
Shoulder, T ;
Strawson, C ;
Wood, P .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2001, 24 (11-12) :1533-1553
[10]  
SUTHERLAND IA, 2001, P PITTSB C NEW ORL 4