Simultaneous measurement of epinephrine and ascorbic acid at the carbon nanotube electrode

被引:8
作者
Hu, CG [1 ]
Wang, WL [1 ]
Liao, KJ [1 ]
Wang, YT [1 ]
机构
[1] Chongqing Univ, Dept Appl Phys, Chongqing 400044, Peoples R China
来源
SCIENCE AND TECHNOLOGY OF NANOMATERIALS - ICMAT 2003 | 2005年 / 23卷
关键词
ascorbic acid; carbon nanotubes; electroanalysis; electrochemistry; epinephrine; voltammetry;
D O I
10.4028/www.scientific.net/JMNM.23.305
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Electrochemical behaviors of epinephrine and ascorbic acid have been studied at the carbon nanotube electrode using cyclic voltammetry. Electrocatalysis has been found for epinephrine redox reactions at the carbon nanotube electrode in the comparison with the glassy carbon electrode. A well-defined oxidative peak for ascorbic acid was observed at the carbon nanotube electrode with the peak potential negative shift versus the glassy carbon electrode. Low level of epinephrine can be determined at the carbon nanotube electrode selectively with high sensitivity in the presence of a large excess of ascorbic acid in the acidic media and in the physiological pH buffer solution.
引用
收藏
页码:305 / 308
页数:4
相关论文
共 20 条
[1]   ELECTROCHEMISTRY AND DETECTION OF SOME ORGANIC AND BIOLOGICAL MOLECULES AT CONDUCTING POLY(3-METHYLTHIOPHENE) ELECTRODES [J].
ATTA, NF ;
GALAL, A ;
KARAGOZLER, AE ;
RUSSELL, GC ;
ZIMMER, H ;
MARK, HB .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (04) :333-341
[2]   SIMULTANEOUS ASSAY OF PLATELET AND PLASMA-CATECHOLAMINES BY HPLC WITH COULOMETRIC DETECTION [J].
BLANDINI, F ;
DERIL, GVM ;
SANCES, G ;
LUCARELLI, C ;
HERBORG, C ;
MARTIGNONI, E .
CHROMATOGRAPHIA, 1993, 36 :164-166
[3]   AN AMPEROMETRIC GLUCOSE ELECTRODE BASED ON CARBON PASTE, CHEMICALLY MODIFIED WITH GLUCOSE-DEHYDROGENASE, NICOTINAMIDE ADENINE-DINUCLEOTIDE, AND A PHENOXAZINE MEDIATOR, COATED WITH A POLY(ESTER SULFONIC-ACID) CATION EXCHANGER [J].
BREMLE, G ;
PERSSON, B ;
GORTON, L .
ELECTROANALYSIS, 1991, 3 (02) :77-86
[4]   PLASTICIZED POLY(VINYL CHLORIDE) AS A PERMSELECTIVE BARRIER MEMBRANE FOR HIGH-SELECTIVITY AMPEROMETRIC SENSORS AND BIOSENSORS [J].
CHRISTIE, IM ;
TRELOAR, PH ;
VADGAMA, P .
ANALYTICA CHIMICA ACTA, 1992, 269 (01) :65-73
[5]   DISPROPORTIONATION DURING ELECTROOXIDATION OF CATECHOLAMINES AT CARBON-FIBER MICROELECTRODES [J].
CIOLKOWSKI, EL ;
MANESS, KM ;
CAHILL, PS ;
WIGHTMAN, RM ;
EVANS, DH ;
FOSSET, B ;
AMATORE, C .
ANALYTICAL CHEMISTRY, 1994, 66 (21) :3611-3617
[6]   QUANTITATION OF EPINEPHRINE AND NOREPINEPHRINE SECRETION FROM INDIVIDUAL ADRENAL-MEDULLARY CELLS BY MICROCOLUMN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
COOPER, BR ;
WIGHTMAN, RM ;
JORGENSON, JW .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 653 (01) :25-34
[7]   DETERMINATION OF CATECHOLAMINES AND URIC-ACID IN BIOLOGICAL-FLUIDS WITHOUT PRETREATMENT, USING CHEMICALLY AMPLIFIED BIOSENSORS [J].
HASEBE, Y ;
HIRANO, T ;
UCHIYAMA, S .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 24 (1-3) :94-97
[8]   SPECTROFLUOROMETRIC FLOW-INJECTION DETERMINATION OF ADRENALINE WITH AN IODINE SOLID-PHASE REACTOR [J].
KOJLO, A ;
CALATAYUD, JM .
ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) :334-338
[9]   GLUCOSE FAST-RESPONSE AMPEROMETRIC SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN ELECTROPOLYMERIZED POLY(ORTHO-PHENYLENEDIAMINE) FILM [J].
MALITESTA, C ;
PALMISANO, F ;
TORSI, L ;
ZAMBONIN, PG .
ANALYTICAL CHEMISTRY, 1990, 62 (24) :2735-2740
[10]  
SALEM FB, 1995, J PHARM SCI, V9, P143