Detection of gentamicin in milk by immunoassay and flow injection analysis with electrochemical measurement

被引:22
作者
Van Es, RM
Setford, SJ [1 ]
Blankwater, YJ
Meijer, D
机构
[1] Cranfield Univ, Cranfield Biotechnol Ctr, Inst Biosci & Technol, Silsoe MK45 4DT, Beds, England
[2] DSM Food Specialties, Dairy Ingredients, NL-2600 MA Delft, Netherlands
关键词
aminoglycoside; electrochemistry; flow-injection analysis; gentamicin; immunoassay; milk; screen-printed electrodes;
D O I
10.1016/S0003-2670(00)01274-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A number of alternative approaches involving immunoassays coupled to few-injection analysis and electrochemical detection have been evaluated with the aim of developing a simple, rapid field-based method for the quantification of gentamicin in milk to within regulatory guide-line levels. Anti-gentamicin antibodies were adsorbed onto nitrocellulose and polycarbonate solid-phase supports and positioned either in contact with flow-cell mounted electrodes or upstream of the electrode-cell assembly. Following the competitive immunoassay, analyte levels were quantified according to the extent of glucose oxidase enzyme label activity, measured electrochemically. The fully assembled flow-cell device (in situ method) was able to distinguish between 0 and 100 mug kg(-1) gentamicin in milk is. <10 min with a coefficient of variation value of 13.2% and with no sample pre-treatment. Performing the incubation step outside of the flow-cell prior to cell assembly and signal measurement required a 90 min incubation step and CV values of up to 38.7%. The in situ assay is simple to perform, automatable and by using cheap, mass-producible screen-printed electrodes, is amenable to the development of single-usage disposable measurement cartridges. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:37 / 47
页数:11
相关论文
共 22 条
[1]  
AGARWAL VG, 1989, J LIQ CHROMATOGR, V12, P3265
[2]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF NEOMYCIN IN MILK USING A HISEP COLUMN [J].
AGARWAL, VK .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1990, 13 (12) :2475-2487
[3]   DOT-ELISA FOR THE RAPID DETECTION OF GENTAMICIN IN MILK [J].
ARA, J ;
GANS, Z ;
SWEENEY, R ;
WOLF, B .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1995, 9 (05) :320-324
[4]   Presumptive identification of sulphonamide and antibiotic residues in milk by microbial inhibitor tests [J].
Aureli, P ;
Ferrini, AM ;
Mannoni, V .
FOOD CONTROL, 1996, 7 (03) :165-168
[5]   GENTAMICIN IN TISSUE AND WHOLE MILK - AN IMPROVED METHOD FOR EXTRACTION AND CLEANUP OF SAMPLES FOR QUANTITATION ON HPLC [J].
FENNELL, MA ;
UBOH, CE ;
SWEENEY, RW ;
SOMA, LR .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1995, 43 (07) :1849-1852
[6]  
HADDAD NS, 1986, AM J VET RES, V47, P1597
[7]   DETECTION OF STREPTOMYCINS IN RAW-MILK BY AN ANTIBODY-CAPTURE IMMUNOASSAY [J].
HAMMER, P ;
KIRCHHOFF, H ;
HAHN, G .
ANALYTICA CHIMICA ACTA, 1993, 275 (1-2) :313-316
[8]   Use of liquid chromatography mass spectrometry in the analysis of residues of antibiotics in meat and milk [J].
Kennedy, DG ;
McCracken, RJ ;
Cannavan, A ;
Hewitt, SA .
JOURNAL OF CHROMATOGRAPHY A, 1998, 812 (1-2) :77-98
[9]   Determination of gentamicin in bovine milk using liquid chromatography with post-column derivatization and fluorescence detection [J].
Kijak, PJ ;
Jackson, J ;
Shaikh, B .
JOURNAL OF CHROMATOGRAPHY B, 1997, 691 (02) :377-382
[10]  
Krcmar P, 1996, VET MED-CZECH, V41, P93