Cantilever surface stress sensors with single-crystalline silicon piezoresistors

被引:30
作者
Rasmussen, PA [1 ]
Hansen, O [1 ]
Boisen, A [1 ]
机构
[1] Tech Univ Denmark, MIC, Dept Micro & Nanotechnol, DK-2800 Lyngby, Denmark
关键词
D O I
10.1063/1.1900299
中图分类号
O59 [应用物理学];
学科分类号
摘要
We present a cantilever with piezoresistive readout optimized for measuring the static deflection due to isotropic surface stress on the surface of the cantilever [Sens. Actuators B 79(2-3), 115 (2001)]. To our knowledge nobody has addressed the difference in physical regimes, and its influence on cantilever sensors with integrated piezoresistive readout, that one finds between typical atomic force microscopy measurements and the surface stress sensors used in, e.g., biochemical measurements. We have simulated the response from piezoresistive cantilevers as a function of resistor type and placement for the two different regimes, i.e., surface stress measurements and force measurements. The model thus provides the means to specifically design piezoresistive cantilevers for surface stress measurements. (c) 2005 American Institute of Physics.
引用
收藏
页码:1 / 3
页数:3
相关论文
共 11 条
  • [1] ADSORPTION-INDUCED SURFACE STRESS AND ITS EFFECTS ON RESONANCE FREQUENCY OF MICROCANTILEVERS
    CHEN, GY
    THUNDAT, T
    WACHTER, EA
    WARMACK, RJ
    [J]. JOURNAL OF APPLIED PHYSICS, 1995, 77 (08) : 3618 - 3622
  • [3] Design issues in SOI-based high-sensitivity piezoresistive cantilever devices
    Kassegne, S
    Madou, M
    Whitten, R
    Zoval, J
    Mather, E
    Sarkar, K
    Hodko, D
    Maity, S
    [J]. SMART STRUCTURES AND MATERIALS 2002: MODELING, SIGNAL PROCESSING, AND CONTROL, 2002, 4693 : 588 - 597
  • [4] NOVEL OPTICAL APPROACH TO ATOMIC FORCE MICROSCOPY
    MEYER, G
    AMER, NM
    [J]. APPLIED PHYSICS LETTERS, 1988, 53 (12) : 1045 - 1047
  • [5] Optimised cantilever biosensor with piezoresistive read-out
    Rasmussen, PA
    Thaysen, J
    Hansen, O
    Eriksen, SC
    Boisen, A
    [J]. ULTRAMICROSCOPY, 2003, 97 (1-4) : 371 - 376
  • [6] Surface stress induced deflections of cantilever plates with applications to the atomic force microscope: Rectangular plates
    Sader, JE
    [J]. JOURNAL OF APPLIED PHYSICS, 2001, 89 (05) : 2911 - 2921
  • [7] Senturia S.D., 2002, MICROSYSTEM DESIGN
  • [8] SMITH CS, 1953, PHYS REV, V94
  • [9] Atomic force microscopy probe with piezoresistive read-out and a highly symmetrical Wheatstone bridge arrangement
    Thaysen, J
    Boisen, A
    Hansen, O
    Bouwstra, S
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2000, 83 (1-3) : 47 - 53
  • [10] High sensitivity piezoresistive cantilever design and optimization for analyte-receptor binding
    Yang, M
    Zhang, X
    Vafai, K
    Ozkan, CS
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2003, 13 (06) : 864 - 872