Channel electrophoresis for kinetic assays

被引:22
作者
Liu, YM [1 ]
Sweedler, JV [1 ]
机构
[1] UNIV ILLINOIS,DEPT CHEM,URBANA,IL 61801
关键词
D O I
10.1021/ac951242y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rectangular channel electrophoresis system and a cylindrical sampling capillary combination allows chemical changes in nanoliter-volume samples to be monitored as a function of time. The electrophoretic microseparation is carried out in a rectangular channel with a 7-cm-long, 40-mu m x 2.5-cm geometry and is coupled to a 50-mu m-i.d. cylindrical sample introduction capillary. The channel width dimension is used as a time axis by moving the outlet of the sampling capillary across the entrance of the separation channel. Detection of the separated analyte bands is achieved with laser-induced fluorescence and spatially resolved detection based on a charge-coupled device. The system is characterized with a series of fluorescein thiocarbamyl amino acid derivatives; limits of detection are < 10(-8) M for amino acids and 10(-9) M (425 zmol) for fluorescein. The ability to achieve a time-based dynamic microseparation is demonstrated by monitoring fluorescent product formation during the enzyme-catalyzed hydrolysis of fluorescein di-beta-D-galactopyranoside (FDG), a commonly used fluorescent substrate for enzymological studies.
引用
收藏
页码:2471 / 2476
页数:6
相关论文
共 34 条
[1]   SIMULTANEOUS DETECTION OF BETA-GALACTOSIDASE ACTIVITY AND SURFACE-ANTIGEN EXPRESSION IN VIABLE HEMATOPOIETIC-CELLS [J].
BERGER, CN ;
TAN, SS ;
STURM, KS .
CYTOMETRY, 1994, 17 (03) :216-223
[2]  
BOCEK P, 1975, J CHROMATOGR, V106, P283
[3]  
BRUNLEY RL, 1991, NUCLEIC ACIDS RES, V19, P4121
[4]   RECTANGULAR CAPILLARY ELECTROPHORESIS - SOME THEORETICAL CONSIDERATIONS [J].
CIFUENTES, A ;
POPPE, H .
CHROMATOGRAPHIA, 1994, 39 (7-8) :391-404
[5]   FLUORESCENCE-BASED ENZYMATIC ASSAY BY CAPILLARY ELECTROPHORESIS LASER-INDUCED FLUORESCENCE DETECTION FOR THE DETERMINATION OF A FEW BETA-GALACTOSIDASE MOLECULES [J].
CRAIG, D ;
ARRIAGA, EA ;
BANKS, P ;
ZHANG, Y ;
RENBORG, A ;
PALCIC, MM ;
DOVICHI, NJ .
ANALYTICAL BIOCHEMISTRY, 1995, 226 (01) :147-153
[6]   GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2637-2642
[7]   ELECTROCHEMICAL DETECTION IN MICROCOLUMN SEPARATIONS [J].
EWING, AG ;
MESAROS, JM ;
GAVIN, PF .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :A527-A537
[8]   CAPILLARY ELECTROPHORESIS [J].
EWING, AG ;
WALLINGFORD, RA ;
OLEFIROWICZ, TM .
ANALYTICAL CHEMISTRY, 1989, 61 (04) :A292-+
[9]   NO INTERMEDIATE CHANNELING IN STEPWISE HYDROLYSIS OF FLUORESCEIN DI-BETA-D-GALACTOSIDE BY BETA-GALACTOSIDASE [J].
FIEDLER, F ;
HINZ, H .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1994, 222 (01) :75-81
[10]   DETERMINATION OF NITRATE, CHLORIDE AND SULFATE IN DRINKING-WATER BY CAPILLARY FREE-ZONE ELECTROPHORESIS [J].
GEBAUER, P ;
DEML, M ;
BOCEK, P ;
JANAK, J .
JOURNAL OF CHROMATOGRAPHY, 1983, 267 (02) :455-457