Study on catalytic adsorptive stripping voltammetry of trace cobalt at bismuth film electrodes

被引:110
作者
Krolicka, A
Bobrowski, A [1 ]
Kalcher, K
Mocak, J
Svancara, I
Vytras, K
机构
[1] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, Dept Bldg Mat, PL-30059 Krakow, Poland
[2] Karl Franzens Univ Graz, Inst Chem Analyt Chem, A-8010 Graz, Austria
[3] Slovak Univ Technol Bratislava, Fac Chem & Food Technol, Dept Analyt Chem, SK-91237 Bratislava, Slovakia
[4] Univ Pardubice, Fac Chem Technol, Dept Analyt Chem, CZ-53210 Pardubice, Czech Republic
关键词
bismuth film electrode; catalytic adsorptive stripping voltammetry; cobalt; dimethylglyoxime; nitrite;
D O I
10.1002/elan.200302763
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Bismuth film electrodes (BiFE) prepared by plating a glassy carbon support ex situ from a solution containing 0.5 M LiBr and 1 M HCl was tested for the determination of cobalt traces using adsorptive stripping voltammetry (AdSV) and catalytic adsorptive stripping voltammetry (CAdSV). AdSV enables one to determine cobalt as the Co(II)-dimethylglyoximate (Co-DMG) complex down to 0.3 mug/L Co. Addition of NaNO2 to the solution containing dimethylglyoxime in ammonia buffer provides a 15-fold enhancement of the voltammetric signal of cobalt due to the catalytic effect occurring during the reduction of Co(II)-DMG. Utilization of the bismuth film electrode under optimized conditions assures a stable catalytic adsorptive stripping voltammetric response for Co, with an extremely high sensitivity (1.75 muA/(mug/L)), good precision (RSD=3%), and a low detection limit (0.07 mug/L Co with 60 s of adsorptive accumulation). The results of the measurement of the catalytic cobalt response in the presence of DMG and nitrite under hydrodynamic amperometric conditions have shown the BiFE to be an attractive and suitable tool for the rapid determination of cobalt at low mug/L level in both batch and flow systems.
引用
收藏
页码:1859 / 1863
页数:5
相关论文
共 29 条
[1]  
Banica F.G., 2000, ENCY ANAL CHEM, P11115
[2]   Electrochemical and spectroscopic investigation of the reduction of dimethylglyoxime at mercury electrodes in the presence of cobalt and nickel [J].
Baxter, LAM ;
Bobrowski, A ;
Bond, AM ;
Heath, GA ;
Paul, RL ;
Mrzljak, R ;
Zarebski, D .
ANALYTICAL CHEMISTRY, 1998, 70 (07) :1312-1323
[3]   EXPLOITATION OF THE NITRITE CATALYTIC EFFECT TO ENHANCE THE SENSITIVITY AND SELECTIVITY OF THE ADSORPTIVE STRIPPING VOLTAMMETRIC METHOD FOR THE DETERMINATION OF COBALT WITH DIMETHYLGLYOXIME [J].
BOBROWSKI, A ;
BOND, AM .
ELECTROANALYSIS, 1992, 4 (10) :975-979
[4]  
Bobrowski A, 2000, ELECTROANAL, V12, P1177, DOI 10.1002/1521-4109(200010)12:15<1177::AID-ELAN1177>3.0.CO
[5]  
2-U
[7]   BATCH SQUARE-WAVE VOLTAMMETRIC AND FLOW-INJECTION AMPEROMETRIC DETERMINATION OF TRACE AMOUNTS OF BROMOFENOXIM [J].
CAI, XH ;
OGOREVC, B ;
BENFENATI, E ;
KALCHER, K ;
NOVIC, M ;
GRABEC, I .
ANALYTICA CHIMICA ACTA, 1995, 310 (01) :153-160
[8]   Pushing the detectability of voltammetry: how low can we go? [J].
Czae, MZ ;
Wang, J .
TALANTA, 1999, 50 (05) :921-928
[9]   Optical characterization of bismuth reversible electrodeposition [J].
deTorresi, SIC ;
Carlos, IA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 414 (01) :11-16
[10]   Applications, potentialities and limitations of adsorptive stripping analysis on mercury film electrodes [J].
Economou, A ;
Fielden, PR .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1997, 16 (05) :286-292