Label-free detection of telomerase activity using guanine electrochemical oxidation signal

被引:50
作者
Eskiocak, Ugur
Ozkan-Ariksoysal, Dilsat
Ozsoz, Mehmet
Oktem, Huseyin Avni [1 ]
机构
[1] Middle E Tech Univ, Dept Biol Sci, TR-06531 Ankara, Turkey
[2] Ege Univ, Fac Pharm, Dept Analyt Chem, TR-35100 Bornova, Turkey
关键词
D O I
10.1021/ac071014r
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Telomerase is an important biomarker for cancer cells and its activation in 85% of all cancer types confers a clinical diagnostic value. A label-free electrochemical assay based on guanine oxidation signal to measure telomerase activity is described. This developed technology combined with a disposable sensor, carbon graphite electrode (CGE), and differential pulse voltammetry (DPV) was performed by using PCR amplicons with/without telomeric repeats as the guanine oxidation signal observed at +1.0 V measured after the immobilization of PCR products. Guanine oxidation signal was chosen as a measure of telomerase activity because a substantial increase in the number of guanines was introduced by the action of telomerase which adds hexameric repeats (TTAGGG)(n) that contain 50% guanine. The developed assay was shown to specifically measure telomerase activity from cell extracts, and elongation rates increased linearly in a concentration dependent manner. Telomerase activity could be detected in cell extracts containing as low as 100 ng/mu L of protein. All of the electrochemical measurements were also confirmed with the conventional TRAP-silver staining assay. Rapidity, simplicity, and the label-free nature of the developed assay make it suitable for practical use in quantitative determination of telomerase activity from clinical samples for diagnosis of cancer.
引用
收藏
页码:8807 / 8811
页数:5
相关论文
共 46 条
[41]   Hybridisation of surface-immobilised single-stranded oligonucleotides and polymer monitored by surface plasmon resonance [J].
Vikholm-Lundin, Inger ;
Piskonen, Reetta ;
Albers, Willem M. .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (07) :1323-1329
[42]   Simultaneous determination of guanine and adenine in DNA using an electrochemically pretreated glassy carbon electrode [J].
Wang, HS ;
Ju, HX ;
Chen, HY .
ANALYTICA CHIMICA ACTA, 2002, 461 (02) :243-250
[43]   Electrochemical nucleic acid biosensors [J].
Wang, J .
ANALYTICA CHIMICA ACTA, 2002, 469 (01) :63-71
[44]   ORIGIN OF CONCATEMERIC T7 DNA [J].
WATSON, JD .
NATURE-NEW BIOLOGY, 1972, 239 (94) :197-&
[45]   A non-isotopic method for the detection of telomerase activity in tumour tissues: TRAP-silver staining assay [J].
Wen, JM ;
Sun, LB ;
Zhang, M ;
Zheng, MH .
JOURNAL OF CLINICAL PATHOLOGY-MOLECULAR PATHOLOGY, 1998, 51 (02) :110-112
[46]   Simultaneous determination of guanine and adenine contents in DNA, RNA and synthetic oligonucleotides using a chemically modified electrode [J].
Zen, JM ;
Chang, MR ;
Ilangovan, G .
ANALYST, 1999, 124 (05) :679-684