Hip joint contact forces during stumbling

被引:163
作者
Bergmann, G [1 ]
Graichen, F [1 ]
Rohlmann, A [1 ]
机构
[1] Charite Univ Med, Biomech Lab, D-12203 Berlin, Germany
关键词
hip; joint; force; implant; endprosthesis; stumbling; telemetry; load;
D O I
10.1007/s00423-003-0434-y
中图分类号
R61 [外科手术学];
学科分类号
摘要
Aim. To determine whether load directions for stumbling are similar to those for common activities and whether stumbling can be realistically simulated under laboratory conditions without endangering the patients. Method. The magnitudes and directions of hip contact forces were measured during real and simulated stumbling and compared with those found during various other everyday activities. Measurements were obtained by use of hip implants with built-in load sensors and telemetry. Results. Peak forces are approximately twice as high during real stumbling as during any other activity and may range higher than eight-times the body weight. Simulated stumbling leads to much lower contact forces, especially if this happens after a warning. Accidental stumbling in everyday situations should, therefore, be avoided, especially in patients with hip replacements or arthrosis. Conclusions. The directions of peak hip contact forces relative to the femoral bone are nearly constant for any activity, including real stumbling. This observation supports the assumption that muscle and bone anatomy plus muscle function are optimized in order to minimize stresses in bone and muscles. Any impairment of such a mechanically balanced system will increase the musculoskeletal loads. Malposition of total hip implants or muscle deficits caused by the surgical approach must, therefore, be avoided or minimized.
引用
收藏
页码:53 / 59
页数:7
相关论文
共 15 条
[1]
HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[2]
Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[3]
INFLUENCE OF SHOES AND HEEL STRIKE ON THE LOADING OF THE HIP-JOINT [J].
BERGMANN, G ;
KNIGGENDORF, H ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1995, 28 (07) :817-827
[4]
MULTICHANNEL STRAIN-GAUGE TELEMETRY FOR ORTHOPEDIC IMPLANTS [J].
BERGMANN, G ;
GRAICHEN, F ;
SIRAKY, J ;
JENDRZYNSKI, H ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1988, 21 (02) :169-176
[5]
IS STAIRCASE WALKING A RISK FOR THE FIXATION OF HIP IMPLANTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1995, 28 (05) :535-553
[6]
Bergmann G, 1997, CLIN ORTHOP RELAT R, P190
[7]
Bergmann G., 1998, HIP SURG MAT DEV, P1
[8]
BERGMANN G, 2001, HIP 98 LOADING HIP J
[9]
TELEMETRIC FORCE MEASUREMENTS ACROSS THE HIP AFTER TOTAL ARTHROPLASTY [J].
DAVY, DT ;
KOTZAR, GM ;
BROWN, RH ;
HEIPLE, KG ;
GOLDBERG, VM ;
HEIPLE, KG ;
BERILLA, J ;
BURSTEIN, AH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (01) :45-50
[10]
4-CHANNEL TELEMETRY SYSTEM FOR INVIVO MEASUREMENT OF HIP-JOINT FORCES [J].
GRAICHEN, F ;
BERGMANN, G .
JOURNAL OF BIOMEDICAL ENGINEERING, 1991, 13 (05) :370-375