Amperometric biosensors based on solid binding matrices applied in food quality monitoring

被引:71
作者
Miertus, S
Katrlik, J
Pizzariello, A
Stred'ansky, M
Svitel, J
Svorc, J
机构
[1] Int Ctr Sci & High Technol, UNIDO Area, I-34122 Trieste, Italy
[2] POLY Tech, I-34122 Trieste, Italy
关键词
biosensors; multichannel sensor; food quality monitoring; composite transducers; SBMs; amperometric biosensor;
D O I
10.1016/S0956-5663(98)00063-3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Solid binding matrix (SBM) based composite transducers have been used for development of series of multibiosensor systems applicable in various fields. Here we present two hybrid three-channel;multibiosensors for simultaneous amperometric operation in food quality control, i.e. glucose/fructose/ethanol multibiosensor, based on glucose oxidase/fructose dehydrogenase/alcohol dehydrogenase surface-modified enzyme electrodes and L-lactate/L-malate/sulfite multibiosensor, based on L-lactate dehydrogenase/L-malate dehydrogenase/sulfite oxidase surface-modified enzyme electrodes. Different parameters have been studied in order to optimize the response of the multibiosensor systems. The multibiosensor showed a good sensitivity, linear range and storage stability. The multibiosensors were used for the determination of glucose, fructose, ethanol, L-lactate, L-malate and sulfite in samples of wine, resulting in a good agreement with data certified by the supplier. Comparison of various designs, surface-modified, bulk-modified and thick-cover, of SBM based biosensors is studied on the example of fructose biosensor. (C) 1998 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:911 / 923
页数:13
相关论文
共 36 条
[1]   POLYPYRROLE-BASED AMPEROMETRIC BIOSENSOR FOR SULFITE DETERMINATION [J].
ADELOJU, SB ;
SHAW, SJ ;
WALLACE, GG .
ELECTROANALYSIS, 1994, 6 (10) :865-870
[2]   Carbon-polymer biocomposites for amperometric sensing [J].
Alegret, S ;
Cespedes, F ;
MartinezFabregas, E ;
Martorell, D ;
Morales, A ;
Centelles, E ;
Munoz, J .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (1-2) :35-44
[3]   KINETIC-BEHAVIOR OF AN AMPEROMETRIC BIOSENSOR MADE OF AN ENZYMATIC CARBON-PASTE AND A NAFION(R) GEL INVESTIGATED BY ROTATING ELECTRODE STUDIES [J].
ANDRIEUX, CP ;
AUDEBERT, P ;
BACCHI, P ;
DIVISIABLOHORN, B .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 394 (1-2) :141-148
[4]   Construction of carbon paste enzyme electrodes for the measurement of L-malate with polyethylene glycol-modified malate dehydrogenase [J].
Cho, JH ;
Yang, JW ;
Yabuki, S ;
Mizutani, F .
DENKI KAGAKU, 1995, 63 (12) :1143-1144
[5]   A new amperometric biosensor for fructose using a carbon paste electrode modified with silica gel coated with Meldola's Blue and fructose 5-dehydrogenase [J].
Garcia, CAB ;
Neto, GD ;
Kubota, LT ;
Grandin, LA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 418 (1-2) :147-151
[6]   NAFION-COATED ELECTRODES WITH HIGH SELECTIVITY FOR CNS ELECTROCHEMISTRY [J].
GERHARDT, GA ;
OKE, AF ;
NAGY, G ;
MOGHADDAM, B ;
ADAMS, RN .
BRAIN RESEARCH, 1984, 290 (02) :390-395
[7]   EVALUATION OF AN OVERDETERMINED SYSTEM BASED ON MULTIPLE ION-SELECTIVE ELECTRODES OF THE SAME TYPE [J].
GLAZIER, SA ;
ARNOLD, MA ;
GLAZIER, JP .
TALANTA, 1988, 35 (03) :215-219
[8]   CARBON-PASTE ELECTRODES MODIFIED WITH ENZYMES, TISSUES, AND CELLS [J].
GORTON, L .
ELECTROANALYSIS, 1995, 7 (01) :23-45
[9]   A GLUCOSE ELECTRODE BASED ON CARBON PASTE CHEMICALLY MODIFIED WITH A FERROCENE-CONTAINING SILOXANE POLYMER AND GLUCOSE-OXIDASE, COATED WITH A POLY(ESTER-SULFONIC ACID) CATION-EXCHANGER [J].
GORTON, L ;
KARAN, HI ;
HALE, PD ;
INAGAKI, T ;
OKAMOTO, Y ;
SKOTHEIM, TA .
ANALYTICA CHIMICA ACTA, 1990, 228 (01) :23-30
[10]  
HAPP N, 1992, SENSOR ACTUAT A-PHYS, V31, P144