Amperometric biosensors based on solid binding matrices applied in food quality monitoring

被引:71
作者
Miertus, S
Katrlik, J
Pizzariello, A
Stred'ansky, M
Svitel, J
Svorc, J
机构
[1] Int Ctr Sci & High Technol, UNIDO Area, I-34122 Trieste, Italy
[2] POLY Tech, I-34122 Trieste, Italy
关键词
biosensors; multichannel sensor; food quality monitoring; composite transducers; SBMs; amperometric biosensor;
D O I
10.1016/S0956-5663(98)00063-3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Solid binding matrix (SBM) based composite transducers have been used for development of series of multibiosensor systems applicable in various fields. Here we present two hybrid three-channel;multibiosensors for simultaneous amperometric operation in food quality control, i.e. glucose/fructose/ethanol multibiosensor, based on glucose oxidase/fructose dehydrogenase/alcohol dehydrogenase surface-modified enzyme electrodes and L-lactate/L-malate/sulfite multibiosensor, based on L-lactate dehydrogenase/L-malate dehydrogenase/sulfite oxidase surface-modified enzyme electrodes. Different parameters have been studied in order to optimize the response of the multibiosensor systems. The multibiosensor showed a good sensitivity, linear range and storage stability. The multibiosensors were used for the determination of glucose, fructose, ethanol, L-lactate, L-malate and sulfite in samples of wine, resulting in a good agreement with data certified by the supplier. Comparison of various designs, surface-modified, bulk-modified and thick-cover, of SBM based biosensors is studied on the example of fructose biosensor. (C) 1998 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:911 / 923
页数:13
相关论文
共 36 条
[31]  
Turner A, 1987, Biosensors: fundamentals and applications
[32]   FUMED-SILICA CONTAINING CARBON-PASTE DEHYDROGENASE BIOSENSORS [J].
WANG, J ;
LIU, J .
ANALYTICA CHIMICA ACTA, 1993, 284 (02) :385-391
[33]   LACTATE BIOSENSOR BASED ON A LACTATE-DEHYDROGENASE NICOTINAMIDE ADENINE-DINUCLEOTIDE BIOCOMPOSITE [J].
WANG, J ;
CHEN, Q .
ELECTROANALYSIS, 1994, 6 (10) :850-854
[34]   THIN-LAYER ELECTROCHEMICAL DETECTOR WITH A GLASSY-CARBON ELECTRODE COATED WITH A BASE-HYDROLYZED CELLULOSIC FILM [J].
WANG, J ;
HUTCHINS, LD .
ANALYTICAL CHEMISTRY, 1985, 57 (08) :1536-1541
[35]   MODIFICATIONS TO A CARBON-PASTE GLUCOSE-SENSING ENZYME ELECTRODE AND A REDUCTION IN THE ELECTROCHEMICAL INTERFERENCE FROM L-ASCORBATE [J].
YABUKI, S ;
MIZUTANI, F .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (3-4) :353-358
[36]   Electrochemical characteristics of a carbon-based thick-film L-lactate biosensor using L-lactate dehydrogenase [J].
Yoon, HC ;
Kim, HS .
ANALYTICA CHIMICA ACTA, 1996, 336 (1-3) :57-65