OBJECTIVE. The variability of consecutive cine phase-contrast MR flow measurements could significantly affect their use for clinical decisions, especially during provocative testing. The purposes of this study were to determine the normal variability of flow and consecutive flow measurements in the main portal vein on MR images and to determine how intraobserver variability, interobserver variability, and MR imager variability affect these measurements. SUBJECTS AND METHODS. MR flow measurements were acquired four consecutive times at the same location in the main portal vein of 12 subjects and three consecutive times at the same location in a nonpulsatile vessel model. All acquisitions were completed within 10 min. All main portal vein MR data sets were evaluated manually in a blinded review by two independent observers during three separate sessions spaced a mean of 4.5 weeks apart. Flow model data sets were evaluated during a single session by one observer. Variabilities were subsequently calculated by a components-of-variance analysis and by the coefficient of variation (SD / mean x 100). RESULTS. Of the total variance, 90% was due to flow variability among subjects (intersubject), 6% to flow variability within one subject (intrasubject), 2% to intraobserver variability, and 2% to interobserver variability. The coefficient of variation of consecutive MR portal vein flow measurements within a single subject was 11% +/- 5% (range, 3-23%). Intra- and interobserver variabilities were 5% +/- 2% (range, 1-11%) and 4% +/- 4% (range, 0- 17%), respectively. MR imager variability was 1% +/- 1% (range, 0-2%). CONCLUSION. The mean variability of consecutive cine phase-contrast MR flow measurements in the main portal vein is 11% +/- 5% and could affect research and clinical protocols that employ this technique.
引用
收藏
页码:1311 / 1315
页数:5
相关论文
共 26 条
[2]   QUANTIFICATION OF LEFT-TO-RIGHT ATRIAL SHUNTS WITH VELOCITY-ENCODED CINE NUCLEAR-MAGNETIC-RESONANCE IMAGING [J].
BRENNER, LD ;
CAPUTO, GR ;
MOSTBECK, G ;
STEIMAN, D ;
DULCE, M ;
CHEITLIN, MD ;
OSULLIVAN, M ;
HIGGINS, CB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (05) :1246-1250
[3]   VOLUMETRIC FLOW-RATES IN THE PORTAL VENOUS SYSTEM - MEASUREMENT WITH CINE PHASE-CONTRAST MR IMAGING [J].
BURKART, DJ ;
JOHNSON, CD ;
MORTON, MJ ;
WOLF, RL ;
EHMAN, RL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (05) :1113-1118
[4]   EVALUATION OF PORTAL VENOUS HYPERTENSION WITH CINE PHASE-CONTRAST MR FLOW MEASUREMENTS - HIGH ASSOCIATION OF HYPERDYNAMIC PORTAL FLOW WITH VARICEAL HEMORRHAGE [J].
BURKART, DJ ;
JOHNSON, CD ;
EHMAN, RL ;
WEAVER, AL ;
ILSTRUP, DM .
RADIOLOGY, 1993, 188 (03) :643-648
[5]   CINE PHASE-CONTRAST MR FLOW MEASUREMENTS - IMPROVED PRECISION USING AN AUTOMATED-METHOD OF VESSEL DETECTION [J].
BURKART, DJ ;
FELMLEE, JP ;
JOHNSON, CD ;
WOLF, RL ;
WEAVER, AL ;
EHMAN, RL .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (03) :469-475
[6]   MR MEASUREMENTS OF MESENTERIC VENOUS FLOW - PROSPECTIVE EVALUATION IN HEALTHY-VOLUNTEERS AND PATIENTS WITH SUSPECTED CHRONIC MESENTERIC ISCHEMIA [J].
BURKART, DJ ;
JOHNSON, CD ;
READING, CC ;
EHMAN, RL .
RADIOLOGY, 1995, 194 (03) :801-806
[7]   RIGHT AND LEFT LUNG PERFUSION - INVITRO AND INVIVO VALIDATION WITH OBLIQUE-ANGLE, VELOCITY-ENCODED CINE MR IMAGING [J].
CAPUTO, GR ;
KONDO, C ;
MASUI, T ;
GERACI, SJ ;
FOSTER, E ;
OSULLIVAN, MM ;
HIGGINS, CB .
RADIOLOGY, 1991, 180 (03) :693-698
[8]  
DAUZAT M, 1989, GASTROENTEROLOGY, V96, P913
[9]   RENAL-ARTERY BLOOD-FLOW - QUANTITATION WITH PHASE-CONTRAST MR-IMAGING WITH AND WITHOUT BREATH-HOLDING [J].
DEBATIN, JF ;
TING, RH ;
WEGMULLER, H ;
SOMMER, FG ;
FREDRICKSON, JO ;
BROSNAN, TJ ;
BOWMAN, BS ;
MYERS, BD ;
HERFKENS, RJ ;
PELC, NJ .
RADIOLOGY, 1994, 190 (02) :371-378
[10]   SEVERITY OF AORTIC REGURGITATION - INTERSTUDY REPRODUCIBILITY OF MEASUREMENTS WITH VELOCITY-ENCODED CINE MR-IMAGING [J].
DULCE, MC ;
MOSTBECK, GH ;
OSULLIVAN, M ;
CHEITLIN, M ;
CAPUTO, GR ;
HIGGINS, CB .
RADIOLOGY, 1992, 185 (01) :235-240