Clinical comparison of two commercial blood culture systems

被引:11
作者
Spanjaard, L [1 ]
Kuijper, EJ [1 ]
Dankert, J [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Med Microbiol, Bacteriol Lab, NL-1100 DD Amsterdam, Netherlands
关键词
D O I
10.1007/s100960000374
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
A prospective, volume-controlled comparison of the BacT/Alert FAN (Organon Teknika, USA) and Vital (bioMerieux, France) blood culture systems was performed ill a university hospital during a period of 11 months. Twenty to 40 mi of blood drawn from an adult patient was distributed equally between a BacT/ Alert FAN and a Vital blood culture set, both consisting of an aerobic and an anaerobic bottle. Bottles were weighed prior to use and after incubation to calculate the blood volume. A compliant pair of aerobic, or anaerobic, bottles of a blood culture was defined as follows: blood volumes were 4-11 mi and the blood volumes in the two bottles differed by less than or equal to 20%. From 120 compliant pairs of aerobic bottles, 135 organisms were recovered, of which 78 were isolated in both bottles, 44 in the BacT/Alert FAN bottle only and 13 in the Vital bottle only (P < 0,0005). In particular, aerobic BacT/Alert FAN bottles yielded more members of the family Enterobacteriaceae (P<0.01). The BacT/Alert FAN system also performed significantly better when comparing anaerobic bottles, and the yield was greater during septic episodes. Both culture systems were similar regarding detection time, recovery during antimicrobial therapy, and the occurrence of false-positive and false-negative bottles. The overall performance of the BacT/Alert FAN system was better than that of the Vital system.
引用
收藏
页码:881 / 885
页数:5
相关论文
共 15 条
  • [1] AVRIL JL, 1995, ANN BIOL CLIN-PARIS, V53, P21
  • [2] Controlled comparative evaluation of BacT/Alert FAN and ESP 80A aerobic media as means for detecting bacteremia and fungemia
    Doern, GV
    Barton, A
    Rao, S
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (09) : 2686 - 2689
  • [3] Fontanals Dionisia, 1998, Clin Microbiol Infect, V4, P88
  • [4] CDC DEFINITIONS FOR NOSOCOMIAL INFECTIONS, 1988
    GARNER, JS
    JARVIS, WR
    EMORI, TG
    HORAN, TC
    HUGHES, JM
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 1988, 16 (03) : 128 - 140
  • [5] CLINICAL COMPARISON OF THE ISOLATOR AND BACT/ALERT AEROBIC BLOOD CULTURE SYSTEMS
    HELLINGER, WC
    CAWLEY, JJ
    ALVAREZ, S
    HOGAN, SF
    HARMSEN, WS
    ILSTRUP, DM
    COCKERILL, FR
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (07) : 1787 - 1790
  • [6] Controlled clinical laboratory comparison of BACTEC plus aerobic/F resin medium with BacT/Alert aerobic FAN medium for detection of bacteremia and fungemia
    Jorgensen, JH
    Mirrett, S
    McDonald, LC
    Murray, PR
    Weinstein, MP
    Fune, J
    Trippy, CW
    Masterson, M
    Reller, LB
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (01) : 53 - 58
  • [7] Multicenter clinical comparison of Resin-containing bottles with standard aerobic and anaerobic bottles for culture of microorganisms from blood
    Lelievre, H
    Gimenez, M
    Vandenesch, F
    Reinhardt, A
    Lenhardt, D
    Just, HM
    Pau, M
    Ausina, V
    Etienne, J
    [J]. EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1997, 16 (09) : 669 - 674
  • [8] CONTROLLED CLINICAL-EVALUATION OF BACTEC PLUS AEROBIC/F AND BACT/ALERT AEROBIC FAN BOTTLES FOR DETECTION OF BLOOD-STREAM INFECTIONS
    POHLMAN, JK
    KIRKLEY, BA
    EASLEY, KA
    BASILLE, BA
    WASHINGTON, JA
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (11) : 2856 - 2858
  • [9] Update on detection of bacteremia and fungemia
    Reimer, LG
    Wilson, ML
    Weinstein, MP
    [J]. CLINICAL MICROBIOLOGY REVIEWS, 1997, 10 (03) : 444 - &
  • [10] COMPARISON OF BACTEC-9240 AND BACT/ALERT BLOOD CULTURE SYSTEMS IN AN ADULT HOSPITAL
    SMITH, JA
    BRYCE, EA
    NGUIYEN, JH
    ROBERTS, FJ
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (07) : 1905 - 1908