Fast T1- and T2-weighted pulmonary MR-imaging in patients with bronchial carcinoma

被引:45
作者
Both, M
Schultze, J
Reuter, A
Bewig, B
Hubner, R
Bobis, I
Noth, R
Heller, A
Biederer, J
机构
[1] Univ Hosp Schleswig Holstein, Dept Diagnost Radiol, D-24105 Kiel, Germany
[2] Univ Hosp Schleswig Holstein, Dept Radiat Therapy, D-24105 Kiel, Germany
[3] Univ Hosp Schleswig Holstein, Dept Internal Med, D-24105 Kiel, Germany
关键词
bronchial carcinoma; lung; MRI; CT;
D O I
10.1016/j.ejrad.2004.05.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A prospective study to evaluate the diagnostic potential and limitations of three fast MRI sequences in patients with bronchial carcinoma based on the comparison with spiral CT. Material and methods: Three fast chest MRI sequences from 20 patients with central or peripheral bronchial carcinoma were evaluated by two observers for relation of tumour to adjacent structures, lymph node enlargement, additional pulmonary lesions and artefacts. The information from MR-imaging was compared with the results from spiral CT. MRI comprised a T1-3D-GRE breath-hold examination ("VIBE", TR/TE 4.5/1.9 ms, flip-angle 12 degrees, matrix 502 x 512, 2.5 mm coronal slices), a breath-hold, T2-HASTE sequence (TR/TE 2000/43 ms, matrix 192 x 256, 10 mm coronal slices) and a respiration-triggered T2-TSE sequence (TR/TE 3000-6000/120 ms, matrix 270 x 512, 6 mm transverse slices). The FOV was adapted individually (380-480 mm). Results: The presence of the primary bronchial carcinoma and infiltration of thoracic structures by tumour tissue could be demonstrated by all sequences. VIBE sequence was more suitable for detecting small pulmonary nodules than the other MRI examinations, but compared to CT still 20% of these lesions were missed. Contrary to VIBE and T2-weighted TSE scans, HASTE sequence was limited in imaging mediastinal lymph nodes due to missing relevant findings in 2/20 patients. HASTE images significantly provided the lowest rate of artefacts in imaging lung parenchyma (P < 0.001 in peripheral parenchyma), but spatial resolution was limited in this sequence. Concerning the differentiation between tumour and adjacent atelectasis (n = 8), T2-weighted TSE imaging was superior to CT and VIBE in all cases and to HASTE sequence in 4/8 patients. Conclusion: The combination of VIBE and HASTE sequence allows for an adaequate imaging of thoracic processes in patients with bronchial carcinoma, limited only in visualizing small pulmonary nodules. To obtain more detail resolution and to differentiate tumour tissue from adjacent atelectasis, T2-TSE examination may be added-in selected cases. (c) 2004 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:478 / 488
页数:11
相关论文
共 28 条
[1]   Magnetic resonance imaging of pulmonary parenchymal disease using a modified breath-hold 3D gradient-echo technique: Initial observations [J].
Bader, TR ;
Semelka, RC ;
Pedro, MS ;
Armao, DM ;
Brown, MA ;
Molina, PL .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (01) :31-38
[2]   Lymph node metastases: Safety and effectiveness of MR imaging with ultrasmall superparamagnetic iron oxide particles - Initial clinical experience [J].
Bellin, MF ;
Roy, C ;
Kinkel, K ;
Thoumas, D ;
Zaim, S ;
Vanel, D ;
Tuchmann, C ;
Richard, F ;
Jacqmin, D ;
Delcourt, A ;
Challier, E ;
Lebret, T ;
Cluzel, P .
RADIOLOGY, 1998, 207 (03) :799-808
[3]   Simulated pulmonary nodules implanted in a dedicated porcine chest phantom: Sensitivity of MR imaging for detection [J].
Biederer, J ;
Schoene, A ;
Freitag, S ;
Reuter, M ;
Heller, M .
RADIOLOGY, 2003, 227 (02) :475-483
[4]   Lung morphology: Fast MR imaging assessment with a volumetric interpolated breath-hold technique: Initial experience with patients [J].
Biederer, J ;
Both, M ;
Graessner, J ;
Liess, C ;
Jakob, P ;
Reuter, M ;
Heller, M .
RADIOLOGY, 2003, 226 (01) :242-249
[5]   Analysis of artefacts and detail resolution of lung MRI with breath-hold T1-weighted gradient-echo and T2-weighted fast spin-echo sequences with respiratory triggering [J].
Biederer, J ;
Reuter, M ;
Both, M ;
Muhle, C ;
Grimm, J ;
Graessner, J ;
Heller, M .
EUROPEAN RADIOLOGY, 2002, 12 (02) :378-384
[6]   Magnetic resonance imaging of the lung with a volumetric interpolated 3D-gradient echo sequence [J].
Biederer, J ;
Graessner, J ;
Heller, M .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (10) :883-887
[7]  
Diederich S, 2002, RADIOLOGE, V42, P608, DOI 10.1007/s00117-002-0772-8
[8]   MR white lung sign: Incidence and significance in pulmonary consolidations [J].
Gaeta, M ;
Minutoli, F ;
Ascenti, G ;
Vinci, S ;
Mazziotti, S ;
Pandolfo, I ;
Blandino, A .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) :890-896
[9]  
Haberkorn U, 2001, LUNG CANCER, V34, pS13
[10]  
Haramati L B, 2000, Magn Reson Imaging Clin N Am, V8, P43