On the benefits of acquiring peptide fragment ions at high measured mass accuracy

被引:45
作者
Scherl, Alexander [1 ]
Shaffer, Scott A. [1 ]
Taylor, Gregory K. [1 ]
Hernandez, Patricia [2 ]
Appel, Ron D. [2 ]
Binz, Pierre-Alain [2 ,3 ]
Goodlett, David R. [1 ]
机构
[1] Univ Washington, Dept Med Chem, Seattle, WA 98195 USA
[2] Univ Geneva, Swiss Inst Bioinformat, Geneva, Switzerland
[3] GeneBio SA, Geneva, Switzerland
关键词
D O I
10.1016/j.jasms.2008.02.005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The advantages and disadvantages of acquiring tandem mass spectra by collision-induced dissociation (CID) of peptides in linear ion trap Fourier-transform hybrid instruments are described. These instruments offer the possibility to transfer fragment ions from the linear ion trap to the FT-based analyzer for analysis with both high resolution and high mass accuracy. In addition, performing CID during the transfer of ions from the linear ion trap (LTQ) to the FT analyzer is also possible in instruments containing an additional collision cell (i.e., the "C-trap" in the LTQ-Orbitrap), resulting in tandem mass spectra over the full m/Z range and not limited by the ejection q value of the LTQ. Our results show that these scan modes have lower duty cycles than tandem mass spectra acquired in the LTQ with nominal mass resolution, and typically result in fewer peptide identifications during data-dependent analysis of complex samples. However, the higher measured mass accuracy and resolution provides more specificity and hence provides a lower false positive ratio for the same number of true positives during database search of peptide tandem mass spectra. In addition, the search for modified and unexpected peptides is greatly facilitated with this data acquisition mode. It is therefore concluded that acquisition of tandem mass spectral data with high measured mass accuracy and resolution is a competitive alternative to "classical" data acquisition strategies, especially in situations of complex searches from large databases, searches for modified peptides, or for peptides resulting from unspecific cleavages.
引用
收藏
页码:891 / 901
页数:11
相关论文
共 26 条
[11]   The quadrupole ion trap mass spectrometer - A small solution to a big challenge [J].
Jonscher, KR ;
Yates, JR .
ANALYTICAL BIOCHEMISTRY, 1997, 244 (01) :1-15
[12]   Top-down protein sequencing and MS3 on a hybrid linear quadrupole ion trap-orbitrap mass spectrometer [J].
Macek, B ;
Waanders, LF ;
Olsen, JV ;
Mann, M .
MOLECULAR & CELLULAR PROTEOMICS, 2006, 5 (05) :949-958
[13]  
MACEK B, 2005, P AM SOC MASS SPECTR
[14]   Dynamic range of mass accuracy in LTQ Orbitrap hybrid mass spectrometer [J].
Makarov, Alexander ;
Denisov, Eduard ;
Lange, Oliver ;
Horning, Stevan .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2006, 17 (07) :977-982
[15]  
Morris HR, 1996, RAPID COMMUN MASS SP, V10, P889, DOI 10.1002/(SICI)1097-0231(19960610)10:8<889::AID-RCM615>3.0.CO
[16]  
2-F
[17]   Higher-energy C-trap dissociation for peptide modification analysis [J].
Olsen, Jesper V. ;
Macek, Boris ;
Lange, Oliver ;
Makarov, Alexander ;
Horning, Stevan ;
Mann, Matthias .
NATURE METHODS, 2007, 4 (09) :709-712
[18]   THE INTERPRETATION OF COLLISION-INDUCED DISSOCIATION TANDEM MASS-SPECTRA OF PEPTIDES [J].
PAPAYANNOPOULOS, IA .
MASS SPECTROMETRY REVIEWS, 1995, 14 (01) :49-73
[19]  
Perkins DN, 1999, ELECTROPHORESIS, V20, P3551, DOI 10.1002/(SICI)1522-2683(19991201)20:18<3551::AID-ELPS3551>3.0.CO
[20]  
2-2