Lessons Learned From Experience With Over 100 Consecutive HeartMate II Left Ventricular Assist Devices

被引:86
作者
John, Ranjit [1 ]
Kamdar, Forum
Eckman, Peter
Colvin-Adams, Monica
Boyle, Andrew
Shumway, Sara
Joyce, Lyle
Liao, Kenneth
机构
[1] Univ Minnesota, Div Cardiothorac Surg, Dept Surg, Minneapolis, MN 55455 USA
关键词
VON-WILLEBRAND SYNDROME; FLOW; PULSATILE; SUPPORT; NONPULSATILE; SYSTEM;
D O I
10.1016/j.athoracsur.2011.06.081
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Background. Continuous-flow left ventricular assist devices (LVADs) such as the HeartMate II have become the therapy of choice in patients with end-stage heart failure. The aim of this study is to report the outcomes in patients receiving the HeartMate II LVAD at a single center and review the lessons learned from this experience. Methods. From June 2005 to June 2010, 130 consecutive patients received the HeartMate II LVAD. Of these, 102 were bridge-to-transplant (BTT), 17 destination therapy, and 11 exchanges for failed HeartMate XVE. This study focuses on the 102 BTT patients. The HeartMate II was approved by the US Food and Drug Administration (FDA) as BTT in April 2008 and 64 patients received this device as BTT since that date. We review our experience with the device as BTT and report on patient survival and adverse events as well as the impact of FDA approval on outcomes. Results. Overall, mean age was 52.6 +/- 12.8 years; 26 (25.5%) were female. Disease etiology was ischemic in 58, nonischemic in 36, and other in 8. Overall, 30-day, 6-month, and 1-year survival for the BTT patients was 95.1%, 83.5%, and 78.8%, respectively. The 6-month survival in 38 patients in the clinical trial (pre-FDA) was 88.8% and was not statistically significant compared with the 76.2% 6-month survival in the 64 patients in the post-FDA approval period (p value = 0.1). Major adverse events among the 102 BTT patients included right ventricular failure in 5 (4.9%), LVAD driveline infections in 25 (24.5%), neurologic events in 10 (9.8%), and gastrointestinal bleeding in 18 (17.6%) patients. In addition, 1 patient (0.98%) had pump thrombus requiring device replacement. Conclusions. Despite significant morbidity, use of the HeartMate II LVAD as BTT provides excellent hemodynamic support and is associated with excellent survival and low mortality. In addition, there needs to be improvement and focused strategies in the areas of gastrointestinal bleeding, driveline infections, and adverse neurologic events for these devices to be able to provide a real long-term alternative to heart transplantation. (Ann Thorac Surg 2011;92:1593-1600) (C) 2011 by The Society of Thoracic Surgeons
引用
收藏
页码:1593 / 1600
页数:8
相关论文
共 26 条
[1]
Peripheral vascular reactivity in patients with pulsatile vs axial flow left ventricular assist device support [J].
Amir, O ;
Radovancevic, B ;
Delgado, RM ;
Kar, B ;
Radovancevic, R ;
Henderson, M ;
Cohn, WE ;
Smart, FW .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2006, 25 (04) :391-394
[2]
The Development of Aortic Insufficiency in Left Ventricular Assist Device-Supported Patients [J].
Cowger, Jennifer ;
Pagani, Francis D. ;
Haft, Jonathan W. ;
Romano, Matthew A. ;
Aaronson, Keith D. ;
Kolias, Theodore J. .
CIRCULATION-HEART FAILURE, 2010, 3 (06) :668-674
[3]
Acquired von Willebrand Syndrome in Continuous-Flow Ventricular Assist Device Recipients [J].
Crow, Sheri ;
Chen, Dong ;
Milano, Carmelo ;
Thomas, William ;
Joyce, Lyle ;
Piacentino, Valentino, III ;
Sharma, Riti ;
Wu, Jogin ;
Arepally, Gowthami ;
Bowles, Dawn ;
Rogers, Joseph ;
Villamizar-Ortiz, Nestor .
ANNALS OF THORACIC SURGERY, 2010, 90 (04) :1263-1269
[4]
Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices [J].
Crow, Sheri ;
John, Ranjit ;
Boyle, Andrew ;
Shumway, Sara ;
Liao, Kenneth ;
Colvin-Adams, Monica ;
Toninato, Carol ;
Missov, Emil ;
Pritzker, Marc ;
Martin, Cindy ;
Garry, Daniel ;
Thomas, William ;
Joyce, Lyle .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (01) :208-215
[5]
Frazier OH, 2007, TEX HEART I J, V34, P275
[6]
Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation [J].
Frazier, OH ;
Rose, EA ;
Oz, MC ;
Dembitsky, W ;
McCarthy, P ;
Radovancevic, B ;
Poirier, VL ;
Dasse, KA .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 122 (06) :1186-1195
[7]
Effects of pulsatile- and continuous-flow left ventricular assist devices on left ventricular unloading [J].
Garcia, Santiago ;
Kandar, Forum ;
Boyle, Andrew ;
Colvin-Adams, Monica ;
Lliao, Kenneth ;
Joyce, Lyle ;
John, Ranjit .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (03) :261-267
[8]
HeartMate II left ventricular assist system: From concept to first clinical use [J].
Griffith, BP ;
Kormos, RL ;
Borovetz, HS ;
Litwak, K ;
Antaki, JF ;
Poirier, VL ;
Butler, KC .
ANNALS OF THORACIC SURGERY, 2001, 71 (03) :S116-S120
[9]
Hemodynamic and exercise performance with Pulsatile and continuous-flow left ventricular assist devices [J].
Haft, Jonathan ;
Armstrong, William ;
Dyke, David B. ;
Aaronson, Keith D. ;
Koelling, Todd M. ;
Farrar, David J. ;
Pagani, Francis D. .
CIRCULATION, 2007, 116 (11) :I8-I15
[10]
Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy [J].
John, Ranjit ;
Kamdar, Forum ;
Liao, Kenneth ;
Colvin-Adams, Monica ;
Boyle, Andrew ;
Joyce, Lyle .
ANNALS OF THORACIC SURGERY, 2008, 86 (04) :1227-1235