Interactive reduced FOV imaging for projection reconstruction and spiral acquisition

被引:12
作者
Schaeffter, T [1 ]
Rasche, V
Börnert, P
Mens, G
机构
[1] Philips Res Labs, Hamburg, Germany
[2] Philips Med Syst, Best, Netherlands
关键词
MRI; reduced FOV; projection reconstruction; spiral;
D O I
10.1016/S0730-725X(01)00373-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
MR fluoroscopy is likely to gain increasing importance for the visualization of dynamic processes such as cardiac function and for the guidance of interventional procedures. In many applications the dynamic processes are restricted to a part of the object under study making reduced field of view (rFOV) imaging desirable. The restriction to a smaller FOV can either be used to increase the spatial or the temporal resolution. In projection reconstruction (PR) and spiral imaging severe backfolding artifacts occur if a rFOV is used. In this paper efficient suppression schemes are proposed for PR- and spiral imaging to avoid backfolding artifacts. Evaluation of the proposed schemes was done on an interactive real-time MR-scanner. Cardiac function studies clearly showed the potential of this technique for PR- and spiral imaging. (C) 2001 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:677 / 684
页数:8
相关论文
共 30 条
[1]   Interventional magnetic resonance - Initial clinical experience with a 1.5-tesla magnetic resonance system combined with c-arm fluoroscopy [J].
Adam, G ;
Neuerburg, J ;
Bucker, A ;
Glowinski, A ;
Vorwerk, D ;
Stargardt, A ;
VanVaals, JJ ;
Gunther, RW .
INVESTIGATIVE RADIOLOGY, 1997, 32 (04) :191-197
[2]   Visualization of MR-compatible catheters by electrically induced local field inhomogeneities:: Evaluation in vivo [J].
Adam, G ;
Glowinski, A ;
Neuerburg, J ;
Bücker, A ;
van Vaals, JJ ;
Günther, RW .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :209-213
[3]  
EGGERS H, 1999, 7 ANN M INT SOC MAGN, V1, P95
[5]   Interactive coronary MRI [J].
Hardy, CJ ;
Darrow, RD ;
Pauly, JM ;
Kerr, AB ;
Dumoulin, CL ;
Hu, BS ;
Martin, KM .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (01) :105-111
[6]   REDUCTION OF FIELD-OF-VIEW FOR DYNAMIC IMAGING [J].
HU, XP ;
PARRISH, T .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (06) :691-694
[7]   MR IMAGING OF LASER-TISSUE INTERACTIONS [J].
JOLESZ, FA ;
BLEIER, AR ;
JAKAB, P ;
RUENZEL, PW ;
HUTTL, K ;
JAKO, GJ .
RADIOLOGY, 1988, 168 (01) :249-253
[8]   Real-time interactive MRI on a conventional scanner [J].
Kerr, AB ;
Pauly, JM ;
Hu, BS ;
Li, KC ;
Hardy, CJ ;
Meyer, CH ;
Macovski, A ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) :355-367
[9]   Time-resolved contrast-enhanced 3D MR angiography [J].
Korosec, FR ;
Frayne, R ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) :345-351
[10]   Effects of polar sampling in k-space [J].
Lauzon, ML ;
Rutt, BK .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :940-949