Intensity modulation with electrons: calculations, measurements and clinical applications

被引:31
作者
Karlsson, MG
Karlsson, M [1 ]
Zackrisson, B
机构
[1] Umea Univ, Dept Radiat Phys, S-90185 Umea, Sweden
[2] Umea Univ, Dept Oncol, S-90185 Umea, Sweden
关键词
D O I
10.1088/0031-9155/43/5/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intensity modulation of electron beams is one step towards truly conformal therapy. This can be realized with the MM50 racetrack microtron that utilizes a scanning beam technique. By adjusting the scan pattern it is possible to obtain arbitrary fluence distributions. Since the monitor chambers in the treatment head are segmented in both x-and y-directions it is possible to verify the fluence distribution to the patient at any time during the treatment. Intensity modulated electron beams have been measured with film and a plane parallel chamber and compared with calculations. The calculations were based on a pencil beam method. An intensity distribution at the multileaf collimator (MLC) level was calculated by superposition of measured pencil beams over scan patterns. By convolving this distribution with a Gaussian pencil beam, which has propagated from the MLC to the isocentre, a fluence distribution at isocentre level was obtained. The agreement between calculations and measurements was within 2% in dose or 1 mm in distance in the penumbra zones. A standard set of intensity modulated electron beams has been developed. These beams have been implemented in a treatment planning system and are used for manual optimization. A clinical example (prostate) of such an application is presented and compared with a standard irradiation technique.
引用
收藏
页码:1159 / 1169
页数:11
相关论文
共 24 条
[11]   THE APPLICATION OF MULTIPLE-SCATTERING THEORY TO THERAPEUTIC ELECTRON DOSIMETRY [J].
JETTE, D ;
PAGNAMENTA, A ;
LANZL, LH ;
ROZENFELD, M .
MEDICAL PHYSICS, 1983, 10 (02) :141-146
[12]   ELECTRON-BEAM CHARACTERISTICS OF THE 50-MEV RACETRACK MICROTRON [J].
KARLSSON, M ;
NYSTROM, H ;
SVENSSON, H .
MEDICAL PHYSICS, 1992, 19 (02) :307-315
[13]   MATCHING OF ELECTRON AND PHOTON BEAMS WITH A MULTI-LEAF COLLIMATOR [J].
KARLSSON, M ;
ZACKRISSON, B .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (03) :317-326
[14]   Exploration of new treatment modalities offered by high energy (up to 50 MeV) electrons and photons [J].
Karlsson, M ;
Zackrisson, B .
RADIOTHERAPY AND ONCOLOGY, 1997, 43 (03) :303-309
[16]   IMPROVED DOSE HOMOGENEITY IN ELECTRON ARC THERAPY ACHIEVED BY A MULTIPLE-ENERGY TECHNIQUE [J].
LEAVITT, DD ;
STEWART, JR ;
EARLEY, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (01) :159-165
[17]  
LEAVITT DD, 1988, INT J RADIAT ONCOL, V16, P489
[18]   Electron dose profile shaping by modulation of a scanning elementary beam [J].
Lief, EP ;
Larsson, A ;
Humm, JL .
MEDICAL PHYSICS, 1996, 23 (01) :33-44
[19]   ELECTRON BOLUS DESIGN FOR RADIOTHERAPY TREATMENT PLANNING - BOLUS DESIGN ALGORITHMS [J].
LOW, DA ;
STARKSCHALL, G ;
BUJNOWSKI, SW ;
WANG, LL ;
HOGSTROM, KR .
MEDICAL PHYSICS, 1992, 19 (01) :115-124
[20]   BEAM CHARACTERISTICS OF A NEW-GENERATION 50 MEV RACETRACK MICROTRON [J].
MASTERSON, ME ;
CHUI, CS ;
FEBO, R ;
HUNG, JD ;
FUKS, Z ;
MOHAN, R ;
LING, CC ;
KUTCHER, GJ ;
BJORK, S ;
ENSTROM, J .
MEDICAL PHYSICS, 1995, 22 (06) :781-792