Bone marrow modified acrylic bone cement for augmentation of osteoporotic cancellous bone

被引:19
作者
Arens, Daniel [1 ]
Rothstock, Stephan [1 ]
Windolf, Markus [1 ]
Boger, Andreas [2 ]
机构
[1] AO Res Inst, CH-7270 Davos, Switzerland
[2] Synthes GmbH, R&D Biomat, CH-4436 Oberdorf, Switzerland
关键词
Bone marrow; PMMA; Porosity; Low modulus; Polymerization temperature; Viscosity; ADJACENT VERTEBRAL FAILURE; MICRO-COMPUTED TOMOGRAPHY; MECHANICAL-PROPERTIES; PERCUTANEOUS VERTEBROPLASTY; FAT-CONTENT; STEM-CELLS; PMMA; BODY; MODEL; PERFUSION;
D O I
10.1016/j.jmbbm.2011.07.007
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
The use of polymethylmethacrylate (PMMA) cement to reinforce fragile or broken vertebral bodies (vertebroplasty) leads to extensive bone stiffening. This might be one reason for fractures at the adjacent vertebrae following this procedure. PMMA with a reduced Young's modulus may be more suitable. The goal of this study was to produce and characterize PMMA bone cements with a reduced Young's modulus by adding bone marrow. Bone cements were produced by combining PMMA with various volume fractions of freshly harvested bone marrow from sheep. Porosity, Young's modulus, yield strength, polymerization temperature, setting time and cement viscosity of different cement modifications were investigated. The samples generated comprised pores with diameters in the range of 30-250 mu m leading to porosity up to 51%. Compared to the control cement, Young's modulus and yield strength decreased from 1830 to 740 MPa and from 58 to 23 MPa respectively by adding 7.5 ml bone marrow to 23 ml premixed cement. The polymerization temperature decreased from 61 to 38 C for cement modification with 7.5 ml of bone marrow. Setting times of the modified cements were lower in comparison to the regular cement (28 min). Setting times increased with higher amounts of added bone marrow from around 16-25 min. The initial viscosities of the modified cements were higher in comparison to the control cement leading to a lower risk of extravasation. The hardening times followed the same trend as the setting times. In conclusion, blending bone marrow with acrylic bone cement seems to be a promising method to increase the compliance of PMMA cement for use in cancellous bone augmentation in osteoporotic patients due to its modified mechanical properties, lower polymerization temperature and elevated initial viscosity. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2081 / 2089
页数:9
相关论文
共 53 条
[1]
Mechanical Properties of Blood-Mixed Polymethylmetacrylate in Percutaneous Vertebroplasty [J].
Ahn, Dong Ki ;
Lee, Song ;
Choi, Dea Jung ;
Park, Soon Yeol ;
Woo, Dae Gon ;
Kim, Chi Hoon ;
Kim, Han Sung .
ASIAN SPINE JOURNAL, 2009, 3 (02) :45-52
[2]
Mechanical properties of adult vertebral cancellous bone: Correlation with collagen intermolecular cross-links [J].
Banse, X ;
Sims, TJ ;
Bailey, AJ .
JOURNAL OF BONE AND MINERAL RESEARCH, 2002, 17 (09) :1621-1628
[3]
High-viscosity cement significantly enhances uniformity of cement filling in vertebroplasty: An experimental model and study on cement leakage [J].
Baroud, Gamal ;
Crookshank, Meghan ;
Bohner, Marc .
SPINE, 2006, 31 (22) :2562-2568
[4]
Osteopromotion by β-tricalcium phosphate/bone marrow hybrid implant for use in spine surgery [J].
Becker, S ;
Maissen, O ;
Igor, P ;
Thierry, S ;
Rahn, B ;
Ingo, W .
SPINE, 2006, 31 (01) :11-17
[5]
Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty [J].
Belkoff, SM ;
Molloy, S .
SPINE, 2003, 28 (14) :1555-1559
[6]
Benneker L.M., 2010, EUR SPINE J
[7]
Benneker LM, 2008, SPINE, V33, pE906, DOI 10.1097/BRS.0b013e318183bb6d
[8]
Adjacent vertebral failure after vertebroplasty - A biomechanical investigation [J].
Berlemann, U ;
Ferguson, SJ ;
Nolte, LP ;
Hein, PF .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (05) :748-752
[9]
Clinical investigations of polymethylmethacrylate cement viscosity during vertebroplasty and related in vitro measurements [J].
Boger, A. ;
Wheeler, K. D. ;
Schenk, B. ;
Heini, P. F. .
EUROPEAN SPINE JOURNAL, 2009, 18 (09) :1272-1278
[10]
Boger A., 2010, ISRN MAT SCI