摘要
The fabrication and testing of Teflon AF-coated channels on silicon and bonding of the same to a similarly coated glass wafer are described. With water or aqueous solutions in such channels, the channels exhibit much better light conduction ability than similar uncoated channels. Although the loss is greater than extruded Teflon AF tubes, light throughput is far superior to channels described in the literature consisting of [110] planes in silicon with 45degrees sidewalls. Absorbance noise levels under actual flow conditions using an LED source, an inexpensive photodiode and a simple operational amplifier circuitry Was 1 x 10(-4) absorbance units over a 10-mm path length (channel 0.17-mm deep x 0.49-mm wide), comparable to many commercially available macroscale flow-through absorbance detectors. Adherence to Beer's law was tested over a 50-fold concentration range of an injected dye, with the linear r(2) relating the concentration to the observed absorbance being 0.9993. Fluorescence detection was tested with fluorescein as the test solute, a high brightness blue LED as the excitation source and an inexpensive miniature PMT. The concentration detection limit was 3 x 10(-9) M and the corresponding mass detection limit was estimated to be 5 x 10 (-16) mol.
引用
收藏
页码:788 / 795
页数:8
相关论文
共 42 条
[31]   Measurement of nitrogen dioxide and nitrous acid using gas-permeable liquid core waveguides [J].
Milani, MR ;
Dasgupta, PK .
ANALYTICA CHIMICA ACTA, 2001, 431 (02) :169-180
[32]  
ROBLES S, 1997, P DUMIC C, P26
[33]   Application of liquid waveguide to Raman spectroscopy in aqueous solution [J].
Song, L ;
Liu, SY ;
Zhelyaskov, V ;
El-Sayed, MA .
APPLIED SPECTROSCOPY, 1998, 52 (10) :1364-1367
[34]  
*TEFL AF, TEFL AF PROD INF
[35]   A light detection cell to be used in a micro analysis system for ammonia [J].
Tiggelaar, RM ;
Veenstra, TT ;
Sanders, RGP ;
Gardeniers, JGE ;
Elwenspoek, MC ;
van den Berg, A .
TALANTA, 2002, 56 (02) :331-339
[36]  
VANDENBERG A, 2000, MICRO TOTAL ANAL SYS
[37]   A SILICON FLOW CELL FOR OPTICAL-DETECTION IN MINIATURIZED TOTAL CHEMICAL-ANALYSIS SYSTEMS [J].
VERPOORTE, E ;
MANZ, A ;
LUDI, H ;
BRUNO, AE ;
MAYSTRE, F ;
KRATTIGER, B ;
WIDMER, HM ;
VANDERSCHOOT, BH ;
DEROOIJ, NF .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 6 (1-3) :66-70
[38]   A miniaturized liquid core waveguide-capillary electrophoresis system with flow injection sample introduction and fluorometric detection using light-emitting diodes [J].
Wang, SL ;
Huang, XJ ;
Fang, ZL ;
Dasgupta, PK .
ANALYTICAL CHEMISTRY, 2001, 73 (18) :4545-4549
[39]   Structural properties of fluorinated amorphous carbon films [J].
Wang, X ;
Harris, HR ;
Bouldin, K ;
Temkin, H ;
Gangopadhyay, S ;
Strathman, MD ;
West, M .
JOURNAL OF APPLIED PHYSICS, 2000, 87 (01) :621-623
[40]   Long pathlength absorbance spectroscopy: trace analysis of Fe(II) using a 4.5m liquid core waveguide [J].
Waterbury, RD ;
Yao, WS ;
Byrne, RH .
ANALYTICA CHIMICA ACTA, 1997, 357 (1-2) :99-102