Accuracy of cornea and lens biometry using anterior segment optical coherence tomography

被引:30
作者
Dunne, Mark C. M. [1 ]
Davies, Leon N. [1 ]
Wolffsohn, James S. [1 ]
机构
[1] Aston Univ, Ophthalm Res Grp, Sch Life & Hlth Sci, Birmingham B4 7ET, W Midlands, England
关键词
biometry; anterior segment optical coherence tomography; accuracy; physical model eyes;
D O I
10.1117/1.2821844
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
We assess the accuracy of the Visante anterior segment optical coherence tomographer (AS-OCT) and present improved formulas for measurement of surface curvature and axial separation. Measurements are made in physical model eyes. Accuracy is compared for measurements of corneal thickness (d(1)) and anterior chamber depth (d(2)) using-built-in AS-OCT software versus the improved scheme. The improved scheme enables measurements of lens thickness (d(3)) and surface curvature, in the form of conic sections specified by vertex radii and conic constants. These parameters are converted to surface coordinates for error analysis. The built-in AS-OCT software typically overestimates [mean +/- standard deviation (SD)]d(1) by + 62 +/- 4 mu m and d(2) by + 4 +/- 88 mu m. The improved scheme reduces d(1) (-0.4 +/- 4 mu m) and d(2) (0 +/- 49 mu m) errors while also reducing d(3) errors from + 218 +/- 90 (uncorrected) to + 14 +/- 123 mu m (corrected). Surface x coordinate errors gradually increase toward the periphery. Considering the central 6-mm zone of each surface, the x coordinate errors for anterior and posterior corneal surfaces reached + 3 +/- 10 and 0 +/- 23 mu m, respectively, with the improved scheme. Those of the anterior and posterior lens surfaces reached + 2 +/- 22 and + 11 +/- 71 mu m, respectively. Our improved scheme reduced AS-OCT errors and could, therefore, enhance pre- and postoperative assessments of kera-torefractive or cataract surgery, including measurement of accommodating intraocular lenses. (C) 2007 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:5
相关论文
共 16 条
[1]
Measurement of the internal diameter and depth of the anterior chamber: IOLMaster versus anterior chamber optical coherence tomographer [J].
Baikoff, G ;
Jodai, HJ ;
Bourgeon, G .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) :1722-1728
[2]
Anterior segment OCT and phakic intraocular lenses:: A perspective [J].
Baikoff, Georges .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11) :1827-1835
[3]
Phakometric measurement of ocular surface radius of curvature and alignment: evaluation of method with physical model eyes [J].
Barry, JC ;
Dunne, M ;
Kirschkamp, T .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2001, 21 (06) :450-460
[4]
BENNETT AG, 1988, OPTOMETRY TODAY, V28, P238
[5]
Operator-induced errors in Hartmann-Shack wavefront sensing: Model eye study [J].
Cervino, Alejandro ;
Hosking, Sarah L. ;
Dunne, Mark C. M. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (01) :115-121
[7]
The thickness of the aging human lens obtained from corrected scheimpflug images [J].
Dubbelman, M ;
Van der Heijde, GL ;
Weeber, HA .
OPTOMETRY AND VISION SCIENCE, 2001, 78 (06) :411-416
[8]
A COMPUTING SCHEME FOR DETERMINATION OF RETINAL CONTOUR FROM PERIPHERAL REFRACTION, KERATOMETRY AND A-SCAN ULTRASONOGRAPHY [J].
DUNNE, MCM .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1995, 15 (02) :133-143
[9]
A newly developed peripheral anterior chamber depth analysis system: principle, accuracy, and reproducibility [J].
Kashiwagi, K ;
Kashiwagi, F ;
Toda, Y ;
Osada, K ;
Tsumura, T ;
Tsukahara, S .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (08) :1030-1035
[10]
Construction of a model eye to simulate Purkinje reflections for the determination of the radii of curvature and of the position of the crystalline lens of the eye [J].
Kirschkamp, T ;
Jöckel, M ;
Wählisch, G ;
Barry, JC .
BIOMEDIZINISCHE TECHNIK, 1998, 43 (11) :318-325