Comparison of different statistical approaches to evaluate the orthogonality of chromatographic separations: Application to reverse phase systems

被引:43
作者
Al Bakain, Ramia [1 ]
Rivals, Isabelle [2 ]
Sassiat, Patrick [1 ]
Thiebaut, Didier [1 ]
Hennion, Marie-Claire [1 ]
Euvrard, Guillaume [2 ]
Vial, Jerome [1 ]
机构
[1] Ecole Super Phys & Chim Ind Ville Paris, Lab Sci Analyt Bioanalyt & Miniaturisat UMR CNRS, ParisTech, F-75005 Paris, France
[2] Ecole Super Phys & Chim Ind Ville Paris, Equipe Stat Appl, ParisTech, F-75005 Paris, France
关键词
RPLC; Orthogonality; ANOVA; Informational theory; Statistical tests of independence; PERFORMANCE LIQUID-CHROMATOGRAPHY; 2-DIMENSIONAL GAS-CHROMATOGRAPHY; STRONGLY BASIC COMPOUNDS; STATIONARY PHASES; ORGANIC-SOLVENT; UNIVERSAL PROCEDURE; SILICA; COLUMNS; CLASSIFICATION; MASS;
D O I
10.1016/j.chroma.2011.03.031
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Selectivity of phase system is of primary concern when designing a bidimensional chromatographic system and looking for the highest degree of orthogonality between the two separations. Several statistical or geometrical criteria can potentially be used to measure the degree of orthogonality. A comparison of eight candidate criteria has been carried out in this study. Analysis of variance (ANOVA) was used to evaluate the relevance of each criterion and its ability to reveal the significance of the influence of factors like pH, stationary phase, and organic modifier. Experimentally, a set of 32 chromatographic systems was evaluated by the same generic gradient with 63 probe solutes, likely to be present in biological and/or environmental samples and covering a wide range of physico-chemical properties: acidic, basic and neutral compounds with different pKa, molecular mass and hydrophobicity (log P). Each chromatographic system was defined by the nature of the stationary phase (8 different silica or grafting chemistries), the pH of the aqueous fraction of the mobile phase (2.5 or 7.0) and the nature of the organic modifier (acetonitrile or methanol). The orthogonality of the 496 couples of chromatographic systems was evaluated and ranked using the eight different approaches: the three correlation coefficients (Pearson. Spearman and Kendall), two geometric criteria characterizing the coverage of the 2D separation space, Slonecker's information similarity and two chi-square statistics of independence between normalized retention times. In fact, there were only seven distinct criteria, since we established the analytical equivalence between the rankings with the likelihood ratio statistics and Slonecker's information similarity. Kendall's correlation coefficient appeared to be the best measure of orthogonality since, according to ANOVA. it exhibited the highest sensitivity to all experimental factors. The chi-square measures, and hence Slonecker's information similarity, performed equally well provided the discretization of the separation space was carried out appropriately. Finally, from the compared study of the factors acting upon orthogonality carried out by ANOVA, it is possible to draw the conclusion that the pH of the mobile phases has the highest impact on the selectivity followed by the type of stationary phase and finally by the organic modifier. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:2963 / 2975
页数:13
相关论文
共 69 条
[41]   High-performance liquid chromatography fractionation using a silver-modified column followed by two-dimensional comprehensive gas chromatography for detailed group-type characterization of oils and oil pollutions [J].
Mao, Debin ;
De Weghe, Hendrik Van ;
Diels, Ludo ;
De Brucker, Nicole ;
Lookman, Richard ;
Vanermen, Guido .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1179 (01) :33-40
[42]   Solvent effects on mobile phases used in liquid chromatography:: factor analysis applied to protonation equilibria and solvatochromic parameters [J].
Marqués, I ;
Fonrodona, G ;
Butí, S ;
Barbosa, J .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (07) :472-479
[43]  
MAY WE, 2000, 870 NIST
[44]   Influence of sample mass on the performance of reversed-phase columns in the analysis of strongly basic compounds by high-performance liquid chromatography [J].
McCalley, DV .
JOURNAL OF CHROMATOGRAPHY A, 1998, 793 (01) :31-46
[45]   Effect of organic solvent modifier and nature of solute on the performance of bonded silica reversed-phase columns for the analysis of strongly basic compounds by high-performance liquid chromatography [J].
McCalley, DV .
JOURNAL OF CHROMATOGRAPHY A, 1996, 738 (02) :169-179
[46]   Comparative evaluation of bonded-silica reversed-phase columns for high-performance liquid chromatography using strongly basic compounds and alternative organic modifiers buffered at acid pH [J].
McCalley, DV .
JOURNAL OF CHROMATOGRAPHY A, 1997, 769 (02) :169-178
[47]   Universal procedure for the assessment of the reproducibility and the classification of silica-based reversed-phase packings - II. Classification of reversed-phase packings [J].
Neue, UD ;
Alden, BA ;
Walter, TH .
JOURNAL OF CHROMATOGRAPHY A, 1999, 849 (01) :101-116
[48]   Universal procedure for the assessment of the reproducibility and the classification of silica-based reversed-phase packings - I. Assessment of the reproducibility of reversed-phase packings [J].
Neue, UD ;
Serowik, E ;
Iraneta, P ;
Alden, BA ;
Walter, TH .
JOURNAL OF CHROMATOGRAPHY A, 1999, 849 (01) :87-100
[49]   Dependence of reversed-phase retention of ionizable analytes on pH, concentration of organic solvent and silanol activity [J].
Neue, UD ;
Phoebe, CH ;
Tran, K ;
Cheng, YF ;
Lu, ZL .
JOURNAL OF CHROMATOGRAPHY A, 2001, 925 (1-2) :49-67
[50]   Conditional Fisher's exact test as a selection criterion for pair-correlation method.: Type I and Type II errors [J].
Rajkó, R ;
Héberger, K .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2001, 57 (01) :1-14