High-resolution, multiple gradient-echo functional MRI at 1.5 T

被引:46
作者
Barth, M [1 ]
Reichenbach, JR [1 ]
Venkatesan, R [1 ]
Moser, E [1 ]
Haacke, EM [1 ]
机构
[1] Univ Vienna, Inst Med Phys, AG NMR, Vienna, Austria
基金
奥地利科学基金会;
关键词
functional MRI; BOLD; multiple gradient-echo; high resolution; human brain; motor cortex; visual cortex;
D O I
10.1016/S0730-725X(98)00191-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A multiple gradient echo, high resolution imaging method is proposed to better visualize different sources of activation in functional magnetic resonance imaging (fMRI) experiments. Eight echoes are collected from 30 ms to 205 ms with an echo spacing of 25 ms. All echoes show significant activation, but each echo reveals its own pattern of activation. From this variability, it appears that large vessel contributions can be separated from small vessel contributions using a fuzzy cluster analysis across echo times. The results demonstrate the importance of a multiple gradient echo data acquisition approach in localizing various vascular contributions to brain activation in fMRI. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:321 / 329
页数:9
相关论文
共 28 条
[11]   INFLOW VERSUS DEOXYHEMOGLOBIN EFFECTS IN BOLD FUNCTIONAL MRI USING GRADIENT ECHOES AT 1.5 T [J].
DUYN, JH ;
MOONEN, CTW ;
VANYPEREN, GH ;
DEBOER, RW ;
LUYTEN, PR .
NMR IN BIOMEDICINE, 1994, 7 (1-2) :83-88
[12]   IN-VIVO VALIDATION OF THE BOLD MECHANISM - A REVIEW OF SIGNAL CHANGES IN GRADIENT-ECHO FUNCTIONAL MRI IN THE PRESENCE OF FLOW [J].
HAACKE, EM ;
LAI, S ;
YABLONSKIY, DA ;
LIN, WL .
INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1995, 6 (2-3) :153-163
[13]   2D AND 3D HIGH-RESOLUTION GRADIENT-ECHO FUNCTIONAL IMAGING OF THE BRAIN - VENOUS CONTRIBUTIONS TO SIGNAL IN MOTOR CORTEX STUDIES [J].
HAACKE, EM ;
HOPKINS, A ;
LAI, S ;
BUCKLEY, P ;
FRIEDMAN, L ;
MELTZER, H ;
HEDERA, P ;
FRIEDLAND, R ;
KLEIN, S ;
THOMPSON, L ;
DETTERMAN, D ;
TKACH, J ;
LEWIN, JS .
NMR IN BIOMEDICINE, 1994, 7 (1-2) :54-62
[14]   INTRAVASCULAR SUSCEPTIBILITY CONTRAST MECHANISMS IN TISSUES [J].
KENNAN, RP ;
ZHONG, JH ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (01) :9-21
[15]   Perfusion imaging by a flow-sensitive alternating inversion recovery (FAIR) technique: Application to functional brain imaging [J].
Kim, SG ;
Tsekos, NV .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (03) :425-435
[16]   POTENTIAL PITFALLS OF FUNCTIONAL MRI USING CONVENTIONAL GRADIENT-RECALLED ECHO TECHNIQUES [J].
KIM, SG ;
HENDRICH, K ;
HU, XP ;
MERKLE, H ;
UGURBIL, K .
NMR IN BIOMEDICINE, 1994, 7 (1-2) :69-74
[17]   Commutator filter: A novel technique for the identification of structures producing significant susceptibility inhomogeneities and its application to functional MRI [J].
Lai, S ;
Reichenbach, JR ;
Haacke, EM .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (05) :781-787
[18]   IDENTIFICATION OF VASCULAR STRUCTURES AS A MAJOR SOURCE OF SIGNAL CONTRAST IN HIGH-RESOLUTION 2D AND 3D FUNCTIONAL ACTIVATION IMAGING OF THE MOTOR CORTEX AT 1.5T - PRELIMINARY-RESULTS [J].
LAI, S ;
HOPKINS, AL ;
HAACKE, EM ;
LI, D ;
WASSERMAN, BA ;
BUCKLEY, P ;
FRIEDMAN, L ;
MELTZER, H ;
HEDERA, P ;
FRIEDLAND, R .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (03) :387-392
[19]   TESLA GRADIENT RECALLED ECHO CHARACTERISTICS OF PHOTIC STIMULATION-INDUCED SIGNAL CHANGES IN THE HUMAN PRIMARY VISUAL-CORTEX [J].
MENON, RS ;
OGAWA, S ;
TANK, DW ;
UGURBIL, K .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (03) :380-386
[20]   Reproducibility and postprocessing of gradient-echo functional MRI to improve localization of brain activity in the human visual cortex [J].
Moser, E ;
Teichtmeister, C ;
Diemling, M .
MAGNETIC RESONANCE IMAGING, 1996, 14 (06) :567-579