Assessing the capabilities of direct analysis in real time mass spectrometry for 5-hydroxymethylfurfural quantitation in honey

被引:48
作者
Chernetsova, Elena S. [1 ]
Morlock, Gertrud E. [1 ,2 ]
机构
[1] Univ Hohenheim, Inst Food Chem, D-70599 Stuttgart, Germany
[2] Univ Giessen, Inst Nutr Sci, D-35392 Giessen, Germany
关键词
Direct analysis in real time mass spectrometry; Honey; 5-Hydroxymethylfurfural; HMF; Carbohydrates; Screening; QUANTIFICATION; CHROMATOGRAPHY; ALCOHOLS;
D O I
10.1016/j.ijms.2012.01.012
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070305 [高分子化学与物理];
摘要
The limitations of direct analysis in real time mass spectrometry (DART-MS) were shown with the example of 5-hydroxymethylfurfural (HMF) quantitation in honey. An accurate analyte quantitation was impossible because the carbohydrate matrix partially degraded to the analyte in the ionization region. However, at a decreased DART temperature of 150 degrees C, the DART-MS screening was possible using two spiked reference samples. The influence of instrumental parameters on the composition of the DART mass spectra for HMF and carbohydrates was investigated. Also, first data on scanning surface analysis with DART-MS were obtained giving rise for further studies in this direction. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:22 / 32
页数:11
相关论文
共 28 条
[21]
National Honey Board, CARB SWEETN HON
[22]
Quantitation of Chemical Warfare Agents Using the Direct Analysis in Real Time (DART) Technique [J].
Nilles, J. Michael ;
Connell, Theresa R. ;
Durst, H. Dupont .
ANALYTICAL CHEMISTRY, 2009, 81 (16) :6744-6749
[23]
Variation in volatile organic compounds in the breath of normal humans [J].
Phillips, M ;
Herrera, J ;
Krishnan, S ;
Zain, M ;
Greenberg, J ;
Cataneo, RN .
JOURNAL OF CHROMATOGRAPHY B, 1999, 729 (1-2) :75-88
[24]
Singhal R.S., 1997, Handbook of Indices of Food Quality and Authenticity, P358
[25]
CHEMICAL INTERACTIONS OF AMINO COMPOUNDS AND SUGARS .3. THE CONVERSION OF D-GLUCOSE TO 5-(HYDROXYMETHYL)-2-FURALDEHYDE [J].
WOLFROM, ML ;
SCHUETZ, RD ;
CAVALIERI, LF .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1948, 70 (02) :514-517
[26]
Bioanalysis without Sample Cleanup or Chromatography: The Evaluation and Initial Implementation of Direct Analysis in Real Time Ionization Mass Spectrometry for the Quantification of Drugs in Biological Matrixes [J].
Yu, Shaoxia ;
Crawford, Elizabeth ;
Tice, Joe ;
Musselman, Brian ;
Wu, Jing-Tao .
ANALYTICAL CHEMISTRY, 2009, 81 (01) :193-202
[27]
Methods for the determination of HMF in honey:: a comparison [J].
Zappalä, A ;
Fallico, B ;
Arena, E ;
Verzera, A .
FOOD CONTROL, 2005, 16 (03) :273-277
[28]
Quantification of small molecules in plasma with direct analysis in real time tandem mass spectrometry, without sample preparation and liquid chromatographic separation [J].
Zhao, Yeping ;
Lam, Michelle ;
Wu, Danlin ;
Mak, Rowena .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (20) :3217-3224