Automated autofluorescence background subtraction algorithm for biomedical Raman spectroscopy

被引:778
作者
Zhao, Jianhua
Lui, Harvey
McLean, David I.
Zeng, Haishan [1 ]
机构
[1] Univ British Columbia, Dept Dermatol & Skin Sci, Lab Adv Med Photon, Vancouver, BC V5Z 1M9, Canada
[2] Vancouver Coastal Hlth Res Inst, BC Canc Res Ctr, Canc Imaging Dept, Vancouver, BC, Canada
关键词
Raman spectroscopy; fluorescence background removal; biomedical Raman; polynomial fitting;
D O I
10.1366/000370207782597003
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 [仪器科学与技术]; 080401 [精密仪器及机械]; 081102 [检测技术与自动化装置];
摘要
A significant advantage of Raman spectroscopy as a noninvasive optical technique is its ability to detect subtle molecular or biochemical signatures within tissue. One of the major challenges for biomedical Raman spectroscopy is the removal of intrinsic autofluorescence background signals, which are usually a few orders of magnitude stronger than those arising from Raman scattering. A number of methods have been proposed for fluorescence background removal including excitation wavelength shifting, Fourier transformation, time gating, and simple or modified polynomial fitting. The single polynomial and the modified multi-polynomial fitting methods are relatively simple and effective, and thus are widely used in biological applications. However, their performance in real-time in vivo applications and low signal-to-noise ratio environments is sub-optimal. An improved automated algorithm for fluorescence removal has been developed based on modified multi-polynomial fitting, but with the addition of (1) a peak-removal procedure during the first iteration, and (2) a statistical method to account for signal noise effects. Experimental results demonstrate that this approach improves the automated rejection of the fluorescence background during real-time Raman spectroscopy and for in vivo measurements characterized by low signal-to-noise ratios.
引用
收藏
页码:1225 / 1232
页数:8
相关论文
共 31 条
[1]
ELIMINATION OF BASELINE VARIATIONS FROM A RECORDED SPECTRUM BY ULTRALOW FREQUENCY FILTERING [J].
ATAKAN, AK ;
BLASS, WE ;
JENNINGS, DE .
APPLIED SPECTROSCOPY, 1980, 34 (03) :369-372
[2]
RAPID NEAR-INFRARED RAMAN-SPECTROSCOPY OF HUMAN TISSUE WITH A SPECTROGRAPH AND CCD DETECTOR [J].
BARAGA, JJ ;
FELD, MS ;
RAVA, RP .
APPLIED SPECTROSCOPY, 1992, 46 (02) :187-190
[3]
Analysis of luminescent samples using subtracted shifted Raman spectroscopy [J].
Bell, SEJ ;
Bourguignon, ESO ;
Dennis, A .
ANALYST, 1998, 123 (08) :1729-1734
[4]
Near-infrared Raman spectrometer systems for human tissue studies [J].
Brennan, JF ;
Wang, Y ;
Dasari, RR ;
Feld, MS .
APPLIED SPECTROSCOPY, 1997, 51 (02) :201-208
[5]
In vivo determination of the molecular composition of artery wall by intravascular Raman spectroscopy [J].
Buschman, HP ;
Marple, ET ;
Wach, ML ;
Bennett, B ;
Schut, TCB ;
Bruining, HA ;
Bruschke, AV ;
van der Laarse, A ;
Puppels, GJ .
ANALYTICAL CHEMISTRY, 2000, 72 (16) :3771-3775
[6]
Caspers PJ, 1998, BIOSPECTROSCOPY, V4, pS31, DOI 10.1002/(SICI)1520-6343(1998)4:5+<S31::AID-BSPY4>3.0.CO
[7]
2-M
[8]
Combined in vivo confocal Raman spectroscopy and confocal microscopy of human skin [J].
Caspers, PJ ;
Lucassen, GW ;
Puppels, GJ .
BIOPHYSICAL JOURNAL, 2003, 85 (01) :572-580
[9]
In vivo chemical investigation of human skin using a confocal Raman fiber optic microprobe -: art. no. 044007 [J].
Chrit, L ;
Hadjur, C ;
Morel, S ;
Sockalingum, G ;
Lebourdon, G ;
Leroy, F ;
Manfait, M .
JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (04)
[10]
POTENTIAL APPLICATIONS OF FT-RAMAN SPECTROSCOPY FOR DERMATOLOGICAL DIAGNOSTICS [J].
EDWARDS, HGM ;
WILLIAMS, AC ;
BARRY, BW .
JOURNAL OF MOLECULAR STRUCTURE, 1995, 347 :379-387