Acquisition, segmentation and tracking of the cerebral vascular tree on 3D magnetic resonance angiography images

被引:77
作者
Flasque, N [1 ]
Desvignes, M [1 ]
Constans, JM [1 ]
Revenu, M [1 ]
机构
[1] Inst Sci Mat & Rayonnement, GREYC, F-14050 Caen, France
关键词
cerebral vascular tree; magnetic resonance angiography;
D O I
10.1016/S1361-8415(01)00038-X
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This paper presents a method for the detection, representation and visualisation of the cerebral vascular tree and its application to magnetic resonance angiography (MRA) images. The detection method is an iterative tracking of the vessel centreline with subvoxel accuracy and precise orientation estimation. This tracking algorithm deals with forks. Centrelines of the vessels are modelled by second-order B-spline. This method is used to obtain a high-level description of the whole vascular network. Applications to real angiographic data are presented. An MRA sequence has been designed, and a global segmentation of the whole vascular tree is realised in three steps. Applications of this work are accurate 3D representation of the vessel centreline and of the vascular tree, and visualisation. The tracking process is also successfully applied to 3D contrast enhanced MR digital subtracted angiography (3D-CE-MRA) of the inferior member vessels. In addition, detection of artery stenosis for routine clinical use is possible due to the high precision of the tracking algorithm. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:173 / 183
页数:11
相关论文
共 29 条
[1]   Orientation space filtering for multiple orientation line segmentation [J].
Chen, J ;
Sato, Y ;
Tamura, S .
1998 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, PROCEEDINGS, 1998, :311-317
[2]  
COATRIEUX JL, 1995, LECT NOTES COMPUTER, V905, P295
[3]  
COHEN L, 1996, TR9612 CEREMADE
[4]  
DU Y, 1998, MAGN RESON IMAGING, V16, pR12
[5]   A NONSMOOTHING APPROACH TO THE ESTIMATION OF VESSEL CONTOURS IN ANGIOGRAMS [J].
FIGUEIREDO, MAT ;
LEITAO, JMN .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1995, 14 (01) :162-172
[6]   Model-based quantitation of 3-D magnetic resonance angiographic images [J].
Frangi, AF ;
Niessen, WJ ;
Hoogeveen, RM ;
van Walsum, T ;
Viergever, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (10) :946-956
[7]   NONLINEAR ANISOTROPIC FILTERING OF MRI DATA [J].
GERIG, G ;
KUBLER, O ;
KIKINIS, R ;
JOLESZ, FA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (02) :221-232
[8]  
Gerig G., 1993, Information Processing in Medical Imaging. 13th International Conference, IPMI '93 Proceedings, P94, DOI 10.1007/BFb0013783
[9]  
Hernandez-Hoyos M, 1999, INT CONGR SER, V1191, P189
[10]   Limits to the accuracy of vessel diameter measurement in MR angiography [J].
Hoogeveen, RM ;
Bakker, CJG ;
Viergever, MA .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (06) :1228-1235