Olfactory detection of ozone and D-limonene: reactants in indoor spaces

被引:40
作者
Cain, W. S.
Schmidt, R.
Wolkoff, P.
机构
[1] Univ Calif San Diego, Chemosensory Percept Lab, Dept Surg Otolaryngol, La Jolla, CA 92093 USA
[2] NRCWE, Indoor Environ Grp, Copenhagen, Denmark
关键词
Ozone; D-limonene; odor; threshold; psychophysics; sensory;
D O I
10.1111/j.1600-0668.2007.00476.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Young adult subjects who occupied a well-ventilated space with low background of level of ozone achieved via carbon-filtration could detect ozone odor at 7 ppb, lower than expected from archival compilations. The outcome was not inconsistent, however, with some observations of recognition, beyond mere detection, at about 15-20 ppb. Individual differences in sensitivity lay at or just below an order of magnitude, rare in olfactory testing and indicative of precision. In a study of D-limonene, subjects again showed high sensitivity and small individual differences. The subjects could detect the odor at 8 and 15 ppb, depending upon whether they occupied a space with or without carbon filtration, respectively. The results argue for use of carbon filtration to measure sensitivity most stringently, although absence of filtration seems not to incur a large penalty. The protocol used here, with collection of hundreds of judgments in a day, yet with little net exposure of the subject to odorant; with verifiably stable delivery; and with analytical confirmation of level should reduce tolerance for outcomes of large differences among subjects and among studies.
引用
收藏
页码:337 / 347
页数:11
相关论文
共 41 条
[1]  
American Industrial Hygiene Association (AIHA), 1989, OD THRESH CHEM EST O
[2]  
[Anonymous], 1999, COMPILATIONS ODOUR T
[3]  
*ASHRAE, 1992, 555192 ASHRAE
[4]   Gas-phase tropospheric chemistry of biogenic volatile organic compounds: a review [J].
Atkinson, R ;
Arey, J .
ATMOSPHERIC ENVIRONMENT, 2003, 37 :S197-S219
[5]   Relationship between outdoor and indoor air quality in eight French schools [J].
Blondeau, P ;
Iordache, V ;
Poupard, O ;
Genin, D ;
Allard, F .
INDOOR AIR, 2005, 15 (01) :2-12
[6]  
BOENIGER MF, 1995, AM IND HYG ASSOC J, V56, P590, DOI 10.1202/0002-8894(1995)056<0590:UOOGDT>2.0.CO
[7]  
2
[8]   INFLUENCE OF CARBON-TREATED AIR ON ODOR PERCEPTION [J].
BRISK, MA ;
TURK, A ;
CAIN, WS .
ATMOSPHERIC ENVIRONMENT, 1983, 17 (05) :1023-1024
[9]   Quantification of ozone levels in indoor environments generated by ionization and ozonolysis air purifiers [J].
Britigan, N ;
Alshawa, A ;
Nizkorodov, SA .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2006, 56 (05) :601-610
[10]   Assessment of pollutant emissions from dry-process photocopiers [J].
Brown, SK .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1999, 9 (04) :259-267