Channel-specific coatings on microfabricated chips

被引:37
作者
Xiong, L [1 ]
Regnier, FE [1 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
关键词
chip technology; immobilized proteins; galactosidase; albumin; proteins;
D O I
10.1016/S0021-9673(01)00904-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper reports channel-specific immobilization of fluorescein-5-isothiocyanate (FITC)-labeled bovine serum albumin and beta -galactosidase on microchips with a central channel and two crossing channels; referred to as a double cross channel configuration. Solvent wells at the termini of all channels were used to store reagents. Coatings were applied in multiple steps using electroosmotically driven flow to deliver reagents to specific channels in the chip. The first step in all coating reactions was derivatization of the capillary walls with an organosilane having a reactive pendant functional group. As the silylating reagent was transported from the reagent storage well to a specific waste well, capillary walls in the route of transport were silylated. Flow was maintained throughout a reaction. The route of transport, and thus the specificity of channel coating, were controlled by the well to which negative potential was applied. Flow in a multichannel network takes the shortest route between the electrodes delivering the motive potential. The second reagent in the reaction was delivered from a different well and took a different path through the channel network, as did other reagents. Only the channel being coated was in the flow path of all the reagents used in the coating process. The zone of immobilization in the case of FITC-labeled albumin was determined with confocal fluorescence microscopy. Enzyme activity of immobilized beta -galactosidase (beta -Gal) was monitored by following the hydrolysis of fluorescein mono-beta -D-galactopyranoside to fluorescein with laser-induced fluorescence. (C) 2001 Published by Elsevier Science B.V.
引用
收藏
页码:165 / 176
页数:12
相关论文
共 11 条
[1]   GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2637-2642
[2]   Electroosmosis- and pressure-driven chromatography in chips using continuous beds [J].
Ericson, C ;
Holm, J ;
Ericson, T ;
Hjertén, S .
ANALYTICAL CHEMISTRY, 2000, 72 (01) :81-87
[3]  
Freemantle M, 1999, CHEM ENG NEWS, V77, P27, DOI 10.1021/cen-v077n044.p027
[4]   Microchip device for performing enzyme assays [J].
Hadd, AG ;
Raymond, DE ;
Halliwell, JW ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3407-3412
[5]   MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP [J].
HARRISON, DJ ;
FLURI, K ;
SEILER, K ;
FAN, ZH ;
EFFENHAUSER, CS ;
MANZ, A .
SCIENCE, 1993, 261 (5123) :895-897
[6]   Capillary electrochromatography of peptides in a microfabricated system [J].
He, B ;
Ji, JY ;
Regnier, FE .
JOURNAL OF CHROMATOGRAPHY A, 1999, 853 (1-2) :257-262
[7]   HIGH-SPEED SEPARATIONS ON A MICROCHIP [J].
JACOBSON, SC ;
HERGENRODER, R ;
KOUTNY, LB ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1994, 66 (07) :1114-1118
[8]   MICROCHIP SEPARATIONS OF NEUTRAL SPECIES VIA MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY [J].
MOORE, AW ;
JACOBSON, SC ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1995, 67 (22) :4184-4189
[9]  
REGNIER FE, 1998, CAPILLARY ELECTROPHO, P683
[10]   PLANAR GLASS CHIPS FOR CAPILLARY ELECTROPHORESIS - REPETITIVE SAMPLE INJECTION, QUANTITATION, AND SEPARATION EFFICIENCY [J].
SEILER, K ;
HARRISON, DJ ;
MANZ, A .
ANALYTICAL CHEMISTRY, 1993, 65 (10) :1481-1488