Enhanced Sensitivity of Lateral Flow Tests Using a Two-Dimensional Paper Network Format

被引:185
作者
Fu, Elain [1 ]
Liang, Tinny [1 ]
Houghtaling, Jared [1 ]
Ramachandran, Sujatha [1 ]
Ramsey, Stephen A. [1 ]
Lutz, Barry [1 ]
Yager, Paul [1 ]
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
关键词
IMMUNOASSAY; INFLUENZA; PERFORMANCE; CHLAMYDIA; BIOASSAYS; PROTEIN; CHIP;
D O I
10.1021/ac201950g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Point-of-care diagnostic assays that are rapid, easy-to-use, and low-cost are needed for use in low-resource settings; the lateral flow test has become the standard bioassay format in such settings because it meets those criteria. However, for a number of analytes, conventional lateral flow tests lack the sensitivity needed to have clinical utility. To address this limitation, we are developing a paper network platform that extends the conventional lateral flow test to two dimensions. The two-dimensional structures allow incorporation of multistep processes for improved sensitivity, while still retaining the positive aspects of conventional lateral flow tests. Here we create an easy-to-use, signal-amplified immunoassay based on a modified commercial strip test for human chorionic gonadotropin, the hormone used to detect pregnancy, and demonstrate an improved limit of detection compared to a conventional lateral flow assay. These results highlight the potential of the paper network platform to enhance access to high-quality diagnostic capabilities in low-resource settings in the developed and developing worlds.
引用
收藏
页码:7941 / 7946
页数:6
相关论文
共 30 条
[1]   Hydroxylamine seeding of colloidal Au nanoparticles in solution and on surfaces [J].
Brown, KR ;
Natan, MJ .
LANGMUIR, 1998, 14 (04) :726-728
[2]   Immunogold-silver staining-on-a-chip biosensor based on cross-flow chromatography's [J].
Cho, Il-Hoon ;
Seo, Sung-Min ;
Paek, Eui-Hwan ;
Paek, Se-Hwan .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (02) :271-277
[3]   Plastic ELISA-on-a-chip based on sequential cross-flow chromatography [J].
Cho, JH ;
Han, SM ;
Paek, EH ;
Cho, IH ;
Paek, SH .
ANALYTICAL CHEMISTRY, 2006, 78 (03) :793-800
[4]  
Chun P, 2009, LATERAL FLOW IMMUNOASSAY, P75, DOI 10.1007/978-1-59745-240-3_5
[5]   Poor Clinical Sensitivity of Rapid Antigen Test for Influenza A Pandemic (H1N1) 2009 Virus [J].
Drexler, Jan Felix ;
Helmer, Angelika ;
Kirberg, Heike ;
Reber, Ulrike ;
Panning, Marcus ;
Mueller, Marcel ;
Hoefling, Katja ;
Matz, Bertfried ;
Drosten, Christian ;
Eis-Huebinger, Anna Maria .
EMERGING INFECTIOUS DISEASES, 2009, 15 (10) :1662-1664
[6]   Use of multiple colorimetric indicators for paper-based microfluidic devices [J].
Dungchai, Wijitar ;
Chailapakul, Orawon ;
Henry, Charles S. .
ANALYTICA CHIMICA ACTA, 2010, 674 (02) :227-233
[7]  
Faulstich K, 2009, LATERAL FLOW IMMUNOASSAY, P157, DOI 10.1007/978-1-59745-240-3_9
[8]   Multiplex Lateral-Flow Test Strips Fabricated by Two-Dimensional Shaping [J].
Fenton, Erin M. ;
Mascarenas, Monica R. ;
Lopez, Gabriel P. ;
Sibbett, Scott S. .
ACS APPLIED MATERIALS & INTERFACES, 2009, 1 (01) :124-129
[9]   Transport in two-dimensional paper networks [J].
Fu, Elain ;
Ramsey, Stephen A. ;
Kauffman, Peter ;
Lutz, Barry ;
Yager, Paul .
MICROFLUIDICS AND NANOFLUIDICS, 2011, 10 (01) :29-35
[10]   Chemical signal amplification in two-dimensional paper networks [J].
Fu, Elain ;
Kauffman, Peter ;
Lutz, Barry ;
Yager, Paul .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 149 (01) :325-328