Universal calibration of surgical instruments for spinal stereotaxy

被引:18
作者
Kim, KD
Johnson, JP
Masciopinto, JE
Bloch, O
Saracen, MJ
Villablanca, JP
机构
[1] Univ Calif Los Angeles, Med Ctr, Div Neurosurg, Sch Med, Los Angeles, CA 90024 USA
[2] Univ Calif Los Angeles, Sch Med, Dept Radiol, Los Angeles, CA 90024 USA
[3] Radion Inc, Burlington, MA USA
关键词
frameless stereotaxy; image guidance; spinal instrumentation; universal instrument registration;
D O I
10.1097/00006123-199901000-00105
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
PURPOSE: To describe new software applications and interchangeable instrumentation enabling the use of standard surgical instruments with image-guided systems for stereotactic spinal procedures. CONCEPT: The ability to adapt essentially any surgical instrument for stereotactic procedures will improve the safety and accuracy of image-guided spinal surgery. RATIONALE: Using universal dynamic registration hardware and software, standard surgical instruments are adapted for real-time image-guided surgery, The Radionics Optical Tracking System (Radionics, Inc., Burlington, MA) has custom software applications and universal hardware adaptation devices for spinal stereotaxy that allows the use of standard instruments for intraoperative guidance. An array of light-emitting diodes can be attached to essentially any rigid instrument with a definable tip and can then be calibrated to the system for intraoperative use. Stereotactic guidance of a drill, tap, and screwdriver may improve screw placement accuracy in spinal surgery because every step of the procedure can be monitored in real time. DISCUSSION: Most stereotactic systems have only a standard probe or limited instruments for localization, targeting, and tracking a procedure. The surgeon then resumes the operation using standard surgical instruments without the benefit of image guidance for the key steps of the procedure. Because each surgical step for screw placement in the spine has a potential for error, use of multiple instruments that can be interchanged for real-time image-guided spinal surgery may increase the accuracy and safety of spinal instrumentation procedures. These techniques can also be applied to intracranial image-guided surgery.
引用
收藏
页码:173 / 177
页数:5
相关论文
共 10 条
[1]   COMPUTER-ASSISTED PEDICLE SCREW FIXATION - A FEASIBILITY STUDY [J].
AMIOT, LP ;
LABELLE, H ;
DEGUISE, JA ;
SATI, M ;
BRODEUR, P ;
RIVARD, CH .
SPINE, 1995, 20 (10) :1208-1212
[2]  
BLOCH O, 1998, ANN M AM ASS NEUR SU
[3]   In vitro simulation - Early results of stereotaxy for pedicle screw placement [J].
Carl, AL ;
Khanuja, HS ;
Sachs, BL ;
Gatto, CA ;
vomLehn, J ;
Vosburgh, K ;
Schenck, J ;
Lorensen, W ;
Rohling, K ;
Disler, D .
SPINE, 1997, 22 (10) :1160-1164
[4]  
Foley KT, 1996, NEUROSURG CLIN N AM, V7, P171
[5]   Computer-aided pedicle screw placement using frameless stereotaxis [J].
Glossop, ND ;
Hu, RW ;
Randle, JA .
SPINE, 1996, 21 (17) :2026-2034
[6]   ACCURACY OF PEDICLE SCREWS IN DORSAL LUMBAR SPINAL-FUSION [J].
JEROSCH, J ;
MALMS, J ;
CASTRO, WHM ;
WAGNER, R ;
WIESNER, L .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1992, 130 (06) :479-483
[7]   APPLICATION OF FRAMELESS STEREOTAXY TO PEDICLE SCREW FIXATION OF THE SPINE [J].
KALFAS, IH ;
KORMOS, DW ;
MURPHY, MA ;
MCKENZIE, RL ;
BARNETT, GH ;
BELL, GR ;
STEINER, CP ;
TRIMBLE, MB ;
WEISENBERGER, JP .
JOURNAL OF NEUROSURGERY, 1995, 83 (04) :641-647
[8]  
Nolte L P, 1995, J Image Guid Surg, V1, P88, DOI 10.1002/(SICI)1522-712X(1995)1:2<88::AID-IGS3>3.0.CO
[9]  
2-H
[10]   Accuracy of computer-assisted pedicle screw placement - An in vivo computed tomography analysis [J].
Schwarzenbach, O ;
Berlemann, U ;
Jost, B ;
Visarius, H ;
Arm, E ;
Langlotz, F ;
Nolte, LP ;
Ozdoba, C .
SPINE, 1997, 22 (04) :452-458