A comparison of multileaf collimator with conformal blocks for the boost phase of dose-escalated conformal prostate radiotherapy

被引:7
作者
Bedford, JL
Khoo, VS
Warrington, AP
Bidmead, AM
Webb, S
Deamaley, DP
机构
[1] Inst Canc Res, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
[2] Royal Marsden NHS Trust, Sutton SM2 5PT, Surrey, England
[3] Inst Canc Res, Acad Dept Radiotherapy & Oncol, Sutton SM2 5PT, Surrey, England
[4] Inst Canc Res, Joint Dept Phys, London SW3 6JJ, England
[5] Royal Marsden NHS Trust, London SW3 6JJ, England
关键词
conformal radiotherapy; dose escalation; prostate cancer; rectum; multileaf collimator; conformal block;
D O I
10.1016/S0167-8140(00)00314-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A multileaf collimator (MLC) is compared with conformal blocks for delivering the boost phase of dose-escalated conformal prostate radiotherapy. When using conformal blocks, the volume of rectum irradiated to 90% (V-90) is lower (1.4 +/- 1.3%, 1 SD) for a three-field plan with gantry angles 0 degrees, 90 degrees, 270 degrees than for a six-held plan with gantry angles 50 degrees, 90 degrees, 130 degrees, 230 degrees, 270 degrees, 310 degrees (2.1 +/- 1.3%, P = 0.002). However, when using an MLC in which the leaves and wedge are oriented at right angles, V-90 is higher (4.7 +/- 3.0%) for a three-field plan than for a six-field plan (2.7 +/- 1.6%, P = 0.05). The larger increase in V-90 for the three-field plan when changing from conformal blocks to MLC is mainly due to the limitation imposed upon the MLC orientation by the use of wedges. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:45 / 50
页数:6
相关论文
共 21 条
[1]   Comparison of a multi-leaf collimator with conformal blocks for the delivery of stereotactically guided conformal radiotherapy [J].
Adams, EJ ;
Cosgrove, VP ;
Shepherd, SF ;
Warrington, AP ;
Bedford, JL ;
Mubata, CD ;
Bidmead, AM ;
Brada, M .
RADIOTHERAPY AND ONCOLOGY, 1999, 51 (03) :205-209
[2]   Implementation of the varian EDW into a commercial RTP system [J].
Beavis, AW ;
Weston, SJ ;
Whitten, VJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (09) :1691-1704
[3]   A comparison of coplanar four-field techniques for conformal radiotherapy of the prostate [J].
Bedford, JL ;
Khoo, VS ;
Oldham, M ;
Dearnaley, DP ;
Webb, S .
RADIOTHERAPY AND ONCOLOGY, 1999, 51 (03) :225-235
[4]   Optimization of coplanar six-field techniques for conformal radiotherapy of the prostate [J].
Bedford, JL ;
Khoo, VS ;
Webb, S ;
Dearnaley, DP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (01) :231-238
[5]   Estimation of the incidence of late bladder and rectum complications after high-dose (70-78 Gy) conformal radiotherapy for prostate cancer, using dose-volume histograms [J].
Boersma, LJ ;
van den Brink, M ;
Bruce, AM ;
Shouman, T ;
Gras, L ;
te Velde, A ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (01) :83-92
[6]  
BRAHME A, 1988, STRAHLENTHER ONKOL, V164, P343
[7]   FITTING OF NORMAL TISSUE TOLERANCE DATA TO AN ANALYTIC-FUNCTION [J].
BURMAN, C ;
KUTCHER, GJ ;
EMAMI, B ;
GOITEIN, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :123-135
[8]   Hip stiffness following mixed conformal neutron and photon radiotherapy: A dose-volume relationship [J].
Chuba, PJ ;
Sharma, R ;
Yudelev, M ;
Duclos, M ;
Shamsa, F ;
Giacalone, S ;
Orton, CG ;
Maughan, RL ;
Forman, JD .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (04) :693-699
[9]   Comparison of radiation side-effects of conformal and conventional radiotherapy in prostate cancer: a randomised trial [J].
Dearnaley, DP ;
Khoo, VS ;
Norman, AR ;
Meyer, L ;
Nahum, A ;
Tait, D ;
Yarnold, J ;
Horwich, A .
LANCET, 1999, 353 (9149) :267-272
[10]   TOLERANCE OF NORMAL TISSUE TO THERAPEUTIC IRRADIATION [J].
EMAMI, B ;
LYMAN, J ;
BROWN, A ;
COIA, L ;
GOITEIN, M ;
MUNZENRIDER, JE ;
SHANK, B ;
SOLIN, LJ ;
WESSON, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :109-122