Saline flush effect for enhancement of aorta and coronary arteries at multidetector CT coronary angiography

被引:37
作者
Kim, Dae Jung [1 ]
Kim, Tae Hoon [1 ]
Kim, Sang Jin [1 ]
Kim, Dong Phil [1 ]
Oh, Chi Suk [1 ]
Ryu, Young Hoon [1 ]
Kim, Young Jin [1 ]
Choi, Byoung Wook [1 ]
机构
[1] Yonsei Univ, Coll Med, Dept Radiol, Seoul 120749, South Korea
关键词
D O I
10.1148/radiol.2453061953
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Purpose: To prospectively investigate the effect of the injection rate of a saline solution as a bolus chaser for the enhancement of the aorta and coronary arteries at multidetector computed tomographic (CT) coronary angiography. Materials and Methods: Institutional review board approved this study, and all patients gave informed consent. One hundred consecutive patients (59 men, 41 women; mean age, 58 years +/- 11 [standard deviation]) underwent 64-section CT coronary angiography for coronary artery disease. They were divided into five groups (each group, n = 20) according to the injection rate of saline solution (3, 4, 5, 6, and 7 mL/sec). Iodinated contrast medium (60 mL) was injected intravenously at a rate of 4 mL/sec, followed by 60 mL saline solution administered intravenously at a rate of 3-7 mL/sec, depending on the groups. Attenuation values of the aortic root, right coronary artery, left anterior descending artery, and left circumflex artery were measured. Analysis of variance with the Scheffe method was used to evaluate statistical significance of the differences in attenuation according to the injection rate of saline solution. Results: The degree of contrast enhancement was affected by the injection rate of saline solution, and the attenuation values were higher as the injection rate increased up to 4-5 mL/sec (P <.05). The values plateaued at rates over 5 mL/sec in the aorta and over 4 mL/sec in the coronary arteries. Conclusion: An injection rate of 4-5 mL/sec as a saline solution chaser is optimal for achieving maximum attenuation values of the aorta or coronary arteries by using 64-section CT with 60 mL contrast material.
引用
收藏
页码:110 / 115
页数:6
相关论文
共 7 条
[1]
Non-invasive 16-row multislice CT coronary angiography: usefulness of saline chaser [J].
Cademartiri, F ;
Mollet, N ;
van der Lugt, A ;
Nieman, K ;
Pattynama, PMT ;
de Feyter, PJ ;
Krestin, GP .
EUROPEAN RADIOLOGY, 2004, 14 (02) :178-183
[2]
Using a saline chaser to decrease contrast media in abdominal CT [J].
Dorio, PJ ;
Lee, FT ;
Henseler, KP ;
Pilot, M ;
Pozniak, MA ;
Winter, TC ;
Shock, SA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (04) :929-934
[3]
Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax [J].
Haage, P ;
Schmitz-Rode, T ;
Hübner, D ;
Piroth, W ;
Günther, RW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (04) :1049-1053
[4]
Factors influencing vascular and hepatic enhancement at CT: Experimental study on injection protocol using a canine model [J].
Han, JK ;
Kim, AY ;
Lee, KY ;
Seo, JB ;
Kim, TK ;
Choi, BI ;
Lhee, CS ;
Han, MC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (03) :400-406
[5]
Thoracic spiral CT: Delivery of contrast material pushed with injectable saline solution in a power injector [J].
Hopper, KD ;
Mosher, TJ ;
Kasales, CJ ;
TenHave, TR ;
Tully, DA ;
Weaver, JS .
RADIOLOGY, 1997, 205 (01) :269-271
[6]
Contrast-enhanced CT with saline flush technique using two automated injectors: How much contrast medium does it save? [J].
Irie, T ;
Kajitani, M ;
Yamaguchi, M ;
Itai, Y .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (02) :287-291
[7]
Abdominal helical CT: Evaluation of optimal doses of intravenous contrast material - A prospective randomized study [J].
Yamashita, Y ;
Komohara, Y ;
Takahashi, M ;
Uchida, M ;
Hayabuchi, N ;
Shimizu, T ;
Narabayashi, I .
RADIOLOGY, 2000, 216 (03) :718-723