摘要
A leaf-setting algorithm is developed for generating arbitrary beam intensity profiles in discrete levels using dynamic multileaf collimators (DMLCs). The algorithm starts with the algebraic expression for the area under the beam profile. It is shown that the coefficients in this expression can be transformed into the specifications for the leaf-setting sequence. It is proven that the algorithm optimizes beam delivery time and total monitor units for the DMLC leaf setting for intensity modulated radiotherapy (IMRT). The algorithm is demonstrated to be applicable to both the 'step-and-shoot' and 'dynamic' type of beam delivery. The graphical interpretation and numerical implementation scheme of the algorithm is illustrated using a simplified example.
引用
收藏
页码:1629 / 1643
页数:15
相关论文
共 12 条
[1]   X-RAY FIELD COMPENSATION WITH MULTILEAF COLLIMATORS [J].
BORTFELD, TR ;
KAHLER, DL ;
WALDRON, TJ ;
BOYER, AL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (03) :723-730
[2]  
Boyer AL, 1997, PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, P13
[3]   THE GENERATION OF INTENSITY-MODULATED FIELDS FOR CONFORMAL RADIOTHERAPY BY DYNAMIC COLLIMATION [J].
CONVERY, DJ ;
ROSENBLOOM, ME .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (06) :1359-1374
[4]   COMBINING MULTILEAF FIELDS TO MODULATE FLUENCE DISTRIBUTIONS [J].
GALVIN, JM ;
CHEN, XG ;
SMITH, RM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (03) :697-705
[5]   Use of a multileaf collimator as a dynamic missing-tissue compensator [J].
Geis, P ;
Boyer, AL ;
Wells, NH .
MEDICAL PHYSICS, 1996, 23 (07) :1199-1205
[6]   SIMULTANEOUS-OPTIMIZATION OF DYNAMIC MULTILEAF COLLIMATION AND SCANNING PATTERNS OR COMPENSATION FILTERS USING A GENERALIZED PENCIL BEAM ALGORITHM [J].
GUSTAFSSON, A ;
LIND, BK ;
SVENSSON, R ;
BRAHME, A .
MEDICAL PHYSICS, 1995, 22 (07) :1141-1156
[7]   GENERATION OF ARBITRARY INTENSITY PROFILES BY DYNAMIC JAWS OR MULTILEAF COLLIMATORS [J].
SPIROU, SV ;
CHUI, CS .
MEDICAL PHYSICS, 1994, 21 (07) :1031-1041
[8]   DYNAMIC X-RAY COMPENSATION FOR CONFORMAL RADIOTHERAPY BY MEANS OF MULTI-LEAF COLLIMATION [J].
STEIN, J ;
BORTFELD, T ;
DORSCHEL, B ;
SCHLEGEL, W .
RADIOTHERAPY AND ONCOLOGY, 1994, 32 (02) :163-173
[9]  
STRAIT J, 1997, MED PHYS, V24, P966
[10]   AN ANALYTICAL SOLUTION FOR THE DYNAMIC CONTROL OF MULTILEAF COLLIMATORS [J].
SVENSSON, R ;
KALLMAN, P ;
BRAHME, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (01) :37-61