Chemical mapping of hot-embossed and UV-laser- ablated microchannels in poly(methyl methacrylate) using carboxylate specific fluorescent probes

被引:39
作者
Johnson, TJ [1 ]
Waddell, EA [1 ]
Kramer, GW [1 ]
Locascio, LE [1 ]
机构
[1] NIST, Ctr Analyt Chem, Gaithersburg, MD 20899 USA
关键词
carboxylate surface group; fluorescein probe; hot imprinting; microchannel; poly(methyl methacrylate); UV laser ablation;
D O I
10.1016/S0169-4332(01)00384-1
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The physical morphology and chemical functionality of fluid microchannels formed in poly(methyl methacrylate) (PMMA) substrates were studied to increase the fundamental understanding of polymer microchannel surface properties for 'lab-on-a-chip' devices. Microchannels were formed by a hot-imprint method using a silicon template or by a laser ablation process (248 nm KrF laser) operating at low to moderate fluence levels (up to 1180 mJ/cm(2)). The carboxylate groups, which are responsible for the surface charges, were fluorescently labeled by reaction with an ethyl-dimethylaminopropyl-carbodiimide hydrochloride/amino-fluorescein solution. Fluorescence microscopy was then used to locate and measure qualitatively the charge present on the microchannel walls. Results suggest that surface charges are localized on the corners of trapezoidal channels formed by the hot-imprint method and that the amount of charge present is significantly less compared to laser-ablated microchannels where charges appear to be distributed uniformly. For substrates irradiated at fluences above the laser ablation threshold, it was found that one pass of the laser produced a surface with greater charge than channels made with multiple passes, that ablation under nitrogen resulted in more charge than ablation under oxygen, and that non-sonicated substrates had more charge than samples that were sonicated after ablation. Trends in the data for sonicated samples are explained through scanning electron microscopy images showing etch depth and UV-laser penetration to depths below the surface of the formed microchannel. Finally, we have determined that the surface charge on the substrate can be modified by using the laser at fluence levels lower than those required to ablate the substrate. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:149 / 159
页数:11
相关论文
共 44 条
[1]   Physico-chemical characterization of the effect of excimer laser irradiation on PMMA thin films [J].
Beauvois, S ;
Renaut, D ;
Lazzaroni, R ;
Laude, LD ;
Bredas, JL .
APPLIED SURFACE SCIENCE, 1997, 109 :218-221
[2]  
Becker H, 2000, MESA MG, P253
[3]  
BRANHAM ML, 1999, J CAP ELECT MICROCHI, V1, P43
[4]   A NOVEL-APPROACH TO ION SEPARATIONS IN SOLUTION - SYNCHRONIZED CYCLIC CAPILLARY ELECTROPHORESIS (SCCE) [J].
BURGGRAF, N ;
MANZ, A ;
VERPOORTE, E ;
EFFENHAUSER, CS ;
WIDMER, HM ;
DEROOIJ, NF .
SENSORS AND ACTUATORS B-CHEMICAL, 1994, 20 (2-3) :103-110
[5]   The effect of pulse repetition rate on laser ablation of polyimide and polymethylmethacrylate-based polymers [J].
Burns, FC ;
Cain, SR .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1996, 29 (05) :1349-1355
[6]   Microfabricated structures for integrated DNA analysis [J].
Burns, MA ;
Mastrangelo, CH ;
Sammarco, TS ;
Man, FP ;
Webster, JR ;
Johnson, BN ;
Foerster, B ;
Jones, D ;
Fields, Y ;
Kaiser, AR ;
Burke, DT .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (11) :5556-5561
[7]   GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2637-2642
[8]   Integrated capillary electrophoresis on flexible silicone microdevices: Analysis of DNA restriction fragments and detection of single DNA molecules on microchips [J].
Effenhauser, CS ;
Bruin, GJM ;
Paulus, A ;
Ehrat, M .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3451-3457
[9]   Integrated capillary electrophoresis devices with an efficient postcolumn reactor in planar quartz and glass chips [J].
Fluri, K ;
Fitzpatrick, G ;
Chiem, N ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1996, 68 (23) :4285-4290
[10]  
Ford SM, 1998, J MICROCOLUMN SEP, V10, P413, DOI 10.1002/(SICI)1520-667X(1998)10:5<413::AID-MCS4>3.0.CO