Quantitative high-throughput analysis of drugs in biological matrices by mass spectrometry

被引:215
作者
Hopfgartner, G [1 ]
Bourgogne, E [1 ]
机构
[1] Univ Geneva, Sch Pharm, Lab Pharmaceut Analyt Chem, CH-1211 Geneva 4, Switzerland
关键词
high-throughput analysis; biological fluids; quantitation; LC-MS;
D O I
10.1002/mas.10050
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
To support pharmacokinetic and drug metabolism studies, LC-MS/MS plays more and more an essential role for the quantitation of drugs and their metabolites in biological matrices. With the new challenges encountered in drug discovery and drug development, new strategies are put in place to achieve high-throughput analysis, using serial and parallel approaches. To speed-up method development and validation, generic approaches with the direct injection of biological fluids is highly desirable. Column-switching, using various packing materials for the extraction columns, is widely applied. Improvement of mass spectrometers performance, and in particular triple quadrupoles, also strongly influences sample preparation strategies, which remain a key element in the bioanalytical process. (C) 2003 Wiley Periodicals, Inc.
引用
收藏
页码:195 / 214
页数:20
相关论文
共 128 条
  • [61] Quantitation of entacapone glucuronide in rat plasma by on-line coupled restricted access media column and liquid chromatography-tandem mass spectrometry
    Keski-Hynnilä, H
    Raanaa, K
    Forsberg, M
    Männistö, P
    Taskinen, J
    Kostiainen, R
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 759 (02): : 227 - 236
  • [62] Description and validation of a staggered parallel high performance liquid chromatography system for good laboratory practice level quantitative analysis by liquid chromatography/tandem mass spectrometry
    King, RC
    Miller-Stein, C
    Magiera, DJ
    Brann, J
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (01) : 43 - 52
  • [63] Cassette-accelerated rapid rat screen: a systematic procedure for the dosing and liquid chromatography/atmospheric pressure ionization tandem mass spectrometric analysis of new chemical entities as part of new drug discovery
    Korfmacher, WA
    Cox, KA
    Ng, KJ
    Veals, J
    Hsieh, YS
    Wainhaus, S
    Broske, L
    Prelusky, D
    Nomeir, A
    White, RE
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (05) : 335 - 340
  • [64] Sample pooling to expedite bioanalysis and pharmacokinetic research
    Kuo, BS
    Van Noord, T
    Feng, MR
    Wright, DS
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 16 (05) : 837 - 846
  • [65] Kyranos J N, 2001, Curr Opin Drug Discov Devel, V4, P719
  • [66] A micromachined chip-based electrospray source for mass spectrometry
    Licklider, L
    Wang, XQ
    Desai, A
    Tai, YC
    Lee, TD
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (02) : 367 - 375
  • [67] Simultaneous screen for microsomal stability and metabolite profile by direct injection turbulent-laminar flow LC-LC and automated tandem mass spectrometry
    Lim, HK
    Chan, KW
    Sisenwine, S
    Scatina, JA
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (09) : 2140 - 2146
  • [68] Ultrahigh pressure reversed-phase capillary liquid chromatography:: Isocratic and gradient elution using columns packed with 1.0-μm particles
    MacNair, JE
    Patel, KD
    Jorgenson, JW
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (03) : 700 - 708
  • [69] Development of high-performance liquid chromatography tandem mass spectrometric methods for the determination of a new oxytocin receptor antagonist (L-368,899) extracted from human plasma and urine: a case of lack of specificity due to the presence of metabolites
    Matuszewski, BK
    Chavez-Eng, CM
    Constanzer, ML
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1998, 716 (1-2): : 195 - 208
  • [70] Rapid bioanalytical determination of dextromethorphan in canine plasma by dilute-and-shoot preparation combined with one minute per sample LC-MS/MS analysis to optimize formulations for drug delivery
    McCauley-Myers, DL
    Eichhold, TH
    Bailey, RE
    Dobrozsi, DJ
    Best, KJ
    Hayes, JW
    Hoke, SH
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 23 (05) : 825 - 835