Voltammetric and amperometric determination of sulfite using an aluminum electrode modified by nickel pentacyanonitrosylferrate film - Application to the analysis of some real samples

被引:58
作者
Pournaghi-Azar, MH [1 ]
Hydarpour, M
Dastangoo, H
机构
[1] Univ Tabriz, Fac Chem, Electroanalyt Chem Lab, Tabriz, Iran
[2] Res Inst Fundamental Sci, Tabriz 51664, Iran
关键词
nickel pentacyanonitrosylferrate; sulfite; electrocatalytic oxidation; amperometry; aluminum electrode; modified electrode;
D O I
10.1016/j.aca.2003.08.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A nickel pentacyanonitrosylferrate (NiPCNF) film modified/Al electrode prepared by a simple and rapid electroless dipping procedure was used for the mediated oxidation of sulfite. The anodic peak current observed in both cyclic voltammetry and constant potential amperometry under hydrodynamic conditions was linearly dependent on the sulfite concentration. The detection limit of the ampeorometric method was 3 x 10(-6) M, low enough for the trace sulfite determination. The analysis with NiPCNF film/Al electrode was selective for sulfite from some concomitant compounds. The proposed hydrodynamic amperometric method was used for the determination of sulfite in sulfite treated sugar, boiler water, sulfur dioxide treated raisins, and dried apricots. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:133 / 141
页数:9
相关论文
共 34 条
[1]   POLYPYRROLE-BASED AMPEROMETRIC BIOSENSOR FOR SULFITE DETERMINATION [J].
ADELOJU, SB ;
SHAW, SJ ;
WALLACE, GG .
ELECTROANALYSIS, 1994, 6 (10) :865-870
[2]   DETERMINATION OF TOTAL AND FREE SULFUR-DIOXIDE IN WINE BY FLOW-INJECTION ANALYSIS AND GAS-DIFFUSION USING PARA-AMINOAZOBENZENE AS THE COLORIMETRIC-REAGENT [J].
BARTROLI, J ;
ESCALADA, M ;
JORQUERA, CJ ;
ALONSO, J .
ANALYTICAL CHEMISTRY, 1991, 63 (21) :2532-2535
[3]   COBALT HEXACYANOFERRATE MODIFIED MICROBAND GOLD ELECTRODE AND ITS ELECTROCATALYTIC ACTIVITY FOR OXIDATION OF NADH [J].
CAI, CX ;
JU, HX ;
CHEN, HY .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 397 (1-2) :185-190
[4]   SULFITE OXIDATION AT A PLATINUM GLASSY-CARBON ELECTRODE - DETERMINATION OF SULFITE BY ION-EXCLUSION CHROMATOGRAPHY WITH AMPEROMETRIC DETECTION [J].
CASELLA, IG ;
MARCHESE, R .
ANALYTICA CHIMICA ACTA, 1995, 311 (02) :199-210
[5]   AUTOMATIC CONTINUOUS-FLOW DETERMINATION OF SULFITE IN THE PRESENCE OF A HIGH-CONCENTRATION OF THIOSULFATE [J].
COSANO, JS ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICA CHIMICA ACTA, 1995, 302 (2-3) :269-274
[6]   Determination of sulphite in wines by gas-diffusion flow injection analysis utilizing spectrophotometric pH-detection [J].
DecnopWeever, LG ;
Kraak, JC .
ANALYTICA CHIMICA ACTA, 1997, 337 (02) :125-131
[7]   A coulometer for determination of residual sulfite following the dechlorination of water [J].
Ekkad, N ;
Huber, CO .
ANALYTICA CHIMICA ACTA, 1996, 332 (2-3) :155-160
[8]   OXIDATIVE AMPEROMETRIC FLOW-INJECTION DETERMINATION OF SULFITE AT AN ELECTROCHEMICALLY PRE-TREATED GLASSY-CARBON ELECTRODE [J].
FOGG, AG ;
FERNANDEZARCINIEGA, MA ;
ALONSO, RM .
ANALYST, 1985, 110 (07) :851-853
[9]   ELECTROCHEMICAL AND SPECTROSCOPIC STUDIES OF COBALT-HEXACYANOFERRATE FILM MODIFIED ELECTRODES [J].
GAO, ZQ ;
WANG, GQ ;
LI, PB ;
ZHAO, ZF .
ELECTROCHIMICA ACTA, 1991, 36 (01) :147-152
[10]   POLYPYRROLE FILM ELECTRODES ELECTROCHEMICALLY DOPED WITH COLLOIDAL PRUSSIAN BLUE [J].
IKEDA, O ;
YONEYAMA, H .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 265 (1-2) :323-327