Electrochemiluminescent biosensors array for the concomitant detection of choline, glucose, glutamate, lactate, lysine and urate

被引:102
作者
Marquette, CA [1 ]
Degiuli, A [1 ]
Blum, LJ [1 ]
机构
[1] Univ Lyon 1, CNRS, UMR 5013, Lab Genie Enzymat & Biomol, F-69622 Villeurbanne, France
关键词
choline; electrochimiluminescence; glucose; glutamate; lactate; lysine; multifunctional bio-sensing chip; uric acid;
D O I
10.1016/S0956-5663(03)00225-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A multifunctional bio-sensing chip was designed based on the electrochemiluminescent (ECL) detection of enzymatically produced hydrogen peroxide. Six different oxidases specific for choline, glucose, glutamate, lactate, lysine and urate were non-covalently immobilised on imidodiacetic acid chelating beads (glucose oxidase only) or on diethylaminoethyl (DEAE) anion exchanger beads, and spotted on the surface of a glassy carbon foil (25 mm(2) square), entrapped in PVA-SbQ photopolymer. The chip measurement was achieved by applying during 3 min a +850 mV potential between the glassy carbon electrode and a platinum pseudo-reference, while capturing a numeric image of the multifunctional bio-sensing chip with a CCD camera. The use of luminol supporting beads (DEAE-Sepharose) included in the sensing layer was shown to enable the achievement of spatially well defined signals, and to solve the hydrogen peroxide parasite signal which appeared between contiguous spots using luminol free in solution. The detection limits of the different biosensor were found to be 1 muM for glutamate, lysine and uric acid, 20 muM for glucose and 2 muM for choline and lactate. The detection ranges were 1-25 muM (uric acid), 1 muM-0.5 mM (glutamate and lysine), 20 muM-2 mM (glucose) and 2 muM-0.2 mM (choline and lactate). The ECL chip was used for the detection of glucose, lactate and uric acid in human serum matrix. Good correlations between measured and expected values were found without the need of internal calibration of the sample, demonstrating the potentiality of the ECL multifunctional bio-sensing chip. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:433 / 439
页数:7
相关论文
共 17 条
  • [1] CHEMILUMINESCENT FLOW-INJECTION ANALYSIS OF GLUCOSE IN DRINKS WITH A BIENZYME FIBEROPTIC BIOSENSOR
    BLUM, LJ
    [J]. ENZYME AND MICROBIAL TECHNOLOGY, 1993, 15 (05) : 407 - 411
  • [2] BLUM LJ, 1997, BIO CHEMI LUMINESCEN
  • [3] Engasser J.-M., 1976, APPLIED BIOCHEMISTRY, V1, P127
  • [4] FRIDOVIC.I, 1965, J BIOL CHEM, V240, P2491
  • [5] Chemiluminometric sensor for simultaneous determination of L-glutamate and L-lysine with immobilized oxidases in a flow injection system
    Kiba, N
    Miwa, T
    Tachibana, M
    Tani, K
    Koizumi, H
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (06) : 1269 - 1274
  • [6] Chemiluminescence flow biosensor for hydrogen peroxide with immobilized reagents
    Li, BX
    Zhang, ZJ
    Jin, Y
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2001, 72 (02) : 115 - 119
  • [7] Luminol electrochemiluminescence-based biosensor for total cholesterol determination in natural samples
    Marquette, CA
    Ravaud, S
    Blum, LJ
    [J]. ANALYTICAL LETTERS, 2000, 33 (09) : 1779 - 1796
  • [8] Luminol electrochemiluminescence-based fibre optic biosensors for flow injection analysis of glucose and lactate in natural samples
    Marquette, CA
    Blum, LJ
    [J]. ANALYTICA CHIMICA ACTA, 1999, 381 (01) : 1 - 10
  • [9] Marquette CA, 2001, LUMINESCENCE, V16, P159, DOI 10.1002/bio.617
  • [10] Biosensor arrays for simultaneous measurement of glucose, lactate, glutamate, and glutamine
    Moser, I
    Jobst, G
    Urban, GA
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (04) : 297 - 302