Impact of heart rhythm status on registration accuracy of the left atrium for catheter ablation of atrial fibrillation

被引:25
作者
Dong, Jun
Dalal, Darshan
Scherr, Daniel
Cheema, Aamir
Nazarian, Saman
Bilchick, Kenneth
Almasry, Ibrahim
Cheng, Alan
Henrikson, Charles A.
Spragg, David
Marine, Joseph E.
Berger, Ronald D.
Calkins, Hugh
机构
[1] Johns Hopkins Univ, Sch Med, Dept Med, Div Cardiol, Baltimore, MD 21218 USA
[2] Med Univ Graz, Dept Med, Div Cardiol, Graz, Austria
关键词
imaging; integration; sinus rhythm; atrial fibrillation; catheter ablation;
D O I
10.1111/j.1540-8167.2007.00956.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Impact of Heart Rhythm on Registration Accuracy. Introduction: Registration accuracy is of crucial importance to the successful use of image integration technique to facilitate atrial fibrillation (AF) ablation. It is well known that a patient's heart rhythm can switch from sinus rhythm (SR) to AF or vice versa during an AF ablation procedure. However, the impact of the heart rhythm change on the accuracy of left atrium (LA) registration has not been studied. Methods: This study included 10 patients who underwent AF ablation. Prior to the ablation procedure, the patients had contrast-enhanced cardiac CT scan obtained during SR (n = 7) or AF (n = 3). Using an image integration system (CartoMerge, Biosense Webster Inc.), LA CT surface reconstruction was registered to the real-time mapping space represented by the LA electroanatomic map. To determine the effect of rhythm change on registration accuracy, LA registration was performed during both SR and AF in each study subject. The distance between the surface of the registered LA CT reconstruction and multiple real-time LA electroanatomic map points (surface-to-point distance) was used as an index for LA registration error. The position error after rhythm change was defined as the surface-to-point distance between the surface of the LA CT reconstruction registered in the initial rhythm and the LA electroanatomic map points sampled during the second rhythm. Results: A total of 90 +/- 12 and 92 +/- 9.5 LA electroanatomic map points were sampled for registration during SR and AF, respectively. No significant difference was found in surface-to-point distance when comparing SR with AF as the underlying rhythm during registration (1.91 +/- 0.24 vs 1.84 +/- 0.38 mm, P = 0.60). The position error after rhythm change was not different from the surface-to-point distance of LA registration conducted during the initial rhythm (2.05 +/- 0.39 vs 1.96 +/- 0.29 mm, P = 0.4). The surface-to-point distance did not differ when comparing LA registration conducted during the same versus different rhythm from that during CT imaging (1.96 +/- 0.29 vs 1.79 +/- 0.32 mm, P = 0.13). Conclusions: Registration error did not differ between LA registrations conducted during the same versus different rhythm as was present during CT imaging. Rhythm changes between SR and AF did not introduce significant error to the LA registration process for catheter ablation of AF. These findings are reassuring and suggest that reregistration is not needed if a patient's rhythm changes from SR to AF or vice versa during an ablation procedure.
引用
收藏
页码:1269 / 1276
页数:8
相关论文
共 13 条
[1]   A conservative approach to performing transseptal punctures without the use of intracardiac echocardiography: Stepwise approach with real-time video clips [J].
Cheng, Alan ;
Calkins, Hugh .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (06) :686-689
[2]   Anatomic stereotactic catheter ablation on three-dimensional magnetic resonance images in real time [J].
Dickfeld, T ;
Calkins, H ;
Zviman, M ;
Kato, R ;
Meininger, G ;
Lickfett, L ;
Berger, R ;
Halperin, H ;
Solomon, SB .
CIRCULATION, 2003, 108 (19) :2407-2413
[3]   Initial experience in the use of integrated electroanatomic mapping with three-dimensional MR/CT images to guide catheter ablation of atrial fibrillation [J].
Dong, J ;
Dickfeld, T ;
Dalal, D ;
Cheema, A ;
Vasamreddy, CR ;
Henrikson, CA ;
Marine, JE ;
Halperin, HR ;
Berger, RD ;
Lima, JAC ;
Bluemke, DA ;
Calkins, H .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (05) :459-466
[4]   Integrated electroanatomic mapping with three-dimensional computed tomographic images for real-time guided ablations [J].
Dong, J ;
Calkins, H ;
Solomon, SB ;
Lai, SH ;
Dalal, D ;
Lardo, A ;
Brem, E ;
Preiss, A ;
Berger, RD ;
Halperin, H ;
Dickfeld, T .
CIRCULATION, 2006, 113 (02) :186-194
[5]   Intracardiac echo-guided image integration: Optimizing strategies for registration [J].
Fahmy, Tamer S. ;
Mlcochova, Hanka ;
Wazni, Oussama M. ;
Patel, Dimpi ;
Cihak, Robert ;
Kanj, Mohamed ;
Beheiry, Salwa ;
Burkhardt, J. David ;
Dresing, Thomas ;
Hao, Steven ;
Tchou, Patrick ;
Kautzner, Josef ;
Schweikert, Robert A. ;
Arruda, Mauricio ;
Saliba, Walid ;
Natale, Andrea .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (03) :276-282
[6]   Factors affecting error in integration of electroanatomic mapping with CT and MR imaging during catheter ablation of atrial fibrillation [J].
Heist, E. Kevin ;
Chevalier, Jianping ;
Holmvang, Godtfred ;
Singh, Jagmeet P. ;
Ellinor, Patrick T. ;
Milan, David J. ;
D'Avila, Andre ;
Mela, Theofanie ;
Ruskin, Jeremy N. ;
Mansour, Moussa .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2006, 17 (01) :21-27
[7]   Pulmonary vein anatomy in patients undergoing catheter ablation of atrial fibrillation - Lessons learned by use of magnetic resonance imaging [J].
Kato, R ;
Lickfett, L ;
Meininger, G ;
Dickfeld, T ;
Wu, R ;
Juang, G ;
Angkeow, P ;
LaCorte, J ;
Bluemke, D ;
Berger, R ;
Halperin, HR ;
Calkins, H .
CIRCULATION, 2003, 107 (15) :2004-2010
[8]   Validation of three-dimensional cardiac image integration: Use of integrated CT image into electroanatomic mapping system to perform catheter ablation of atrial fibrillation [J].
Kistler, PM ;
Earley, MJ ;
Harris, S ;
Abrams, D ;
Ellis, S ;
Sporton, SC ;
Schilling, RJ .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (04) :341-348
[9]   Integration of cardiac CT/MR imaging with three-dimensional electroanatomical mapping to guide catheter manipulation in the left atrium: Implications for catheter ablation of atrial fibrillation [J].
Malchano, Zachary J. ;
Neuzil, Petr ;
Cury, Ricardo C. ;
Holmvang, Godtfred ;
Weichet, Jiri ;
Schmidt, Ehud J. ;
Ruskin, Jeremy N. ;
Reddy, Vivek Y. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (11) :1221-1229
[10]   Accuracy of integration of multislice computed tomography imaging into three-dimensional electroanatomic mapping for real-time guided radiofrequency ablation of left atrial fibrillation - Influence of heart rhythm and radiofrequency lesions [J].
Martinek, Martin ;
Nesser, Hans-Joachim ;
Aichinger, Josef ;
Boehm, Gernot ;
Purerfellner, Helmut .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2006, 17 (02) :85-92