Source and detector calibration in the UV and VUV at BESSY II

被引:39
作者
Richter, M [1 ]
Hollandt, J [1 ]
Kroth, U [1 ]
Paustian, W [1 ]
Rabus, H [1 ]
Thornagel, R [1 ]
Ulm, G [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
关键词
D O I
10.1088/0026-1394/40/1/324
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
After the shutdown of the BESSY I electron storage ring, PTB's two normal-incidence monochromator beamlines for the calibration of radiation sources and detectors in the wavelength range from 40 nm to 400 nm were transferred to PTB's new radiometry laboratory at BESSY II. In this paper, the beamlines and their properties are briefly described. First results for the calibration of secondary source standards and detector standards at BESSY II are shown and demonstrate the successful re-establishment of the measurement capabilities. In the ultraviolet, calibration of deuterium lamps was reproduced within 1% and of silicon trap photodetectors within 0.2%.
引用
收藏
页码:S107 / S110
页数:4
相关论文
共 13 条
[1]   HIGH-CURRENT HOLLOW-CATHODE AS A RADIOMETRIC TRANSFER STANDARD SOURCE FOR THE EXTREME VACUUM ULTRAVIOLET [J].
DANZMANN, K ;
GUNTHER, M ;
FISCHER, J ;
KOCK, M ;
KUHNE, M .
APPLIED OPTICS, 1988, 27 (23) :4947-4951
[2]   HIGH-PRECISION SOFT-X-RAY REFLECTOMETER [J].
FUCHS, D ;
KRUMREY, M ;
MULLER, P ;
SCHOLZE, F ;
ULM, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :2248-2250
[3]   A BEAM LINE FOR RADIANT POWER MEASUREMENTS OF VACUUM ULTRAVIOLET AND ULTRAVIOLET SOURCES IN THE WAVELENGTH RANGE 40-400-NM [J].
HOLLANDT, J ;
JANS, W ;
KUHNE, M ;
LINDENLAUF, F ;
WENDE, B .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :1278-1281
[4]   HIGH-CURRENT HOLLOW-CATHODE SOURCE AS A RADIANT INTENSITY STANDARD IN THE 40-125-NM WAVELENGTH RANGE [J].
HOLLANDT, J ;
KUHNE, M ;
WENDE, B .
APPLIED OPTICS, 1994, 33 (01) :68-74
[5]   A CCPR international comparison of spectral radiance measurements in the air-ultraviolet [J].
Lambe, RP ;
Saunders, R ;
Gibson, C ;
Hollandt, J ;
Tegeler, E .
METROLOGIA, 2000, 37 (01) :51-54
[6]   Synchrotron-radiation-operated cryogenic electrical-substitution radiometer as the high-accuracy primary detector standard in the ultraviolet, vacuum-ultraviolet, and soft-x-ray spectral ranges [J].
Rabus, H ;
Persch, V ;
Ulm, G .
APPLIED OPTICS, 1997, 36 (22) :5421-5440
[7]   The two normal-incidence monochromator beam lines of PTB at BESSY II [J].
Richter, M ;
Hollandt, J ;
Kroth, U ;
Paustian, W ;
Rabus, H ;
Thornagel, R ;
Ulm, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 :605-608
[8]   Radiometry using synchrotron radiation at PTB [J].
Richter, M ;
Ulm, G .
JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1999, 101 :1013-1018
[9]   The PTB high-accuracy spectral responsivity scale in the ultraviolet [J].
Richter, M ;
Johannsen, U ;
Kuschnerus, P ;
Kroth, U ;
Rabus, H ;
Ulm, G ;
Werner, L .
METROLOGIA, 2000, 37 (05) :515-518
[10]  
RICHTER M, 2001, BESSY ANN REPORT