摘要
A review of solid state microdosimetry is presented with an emphasis on silicon-based devices, The historical foundations and basics of microdosimetry are briefly provided. Various methods of experimental regional microdosimetry are discussed to facilitate a comparison with the more recent development of silicon microdosimetry. In particular, the performance characteristics of a proportional gas counter and a silicon microdosimeter are compared. Recent improvements in silicon microdosimetry address the issues of requirement specification, non-spherical shape, tissue equivalence, sensitive volume definition (charge collection complexity) and low noise requirements which have previously impeded the implementation of silicon-based microdosimetry. A prototype based on silicon-on-insulator technology is described along with some example results from clinical high LET radiotherapy facilities. A brief summary of the applications of microdosimetry is included. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:135 / 157
页数:23
相关论文
共 75 条
[1]   ESTIMATING THE DIMENSIONS OF THE SEU-SENSITIVE VOLUME [J].
ABDELKADER, WG ;
MCNULTY, PJ ;
ELTELEATY, S ;
LYNCH, JE ;
KHONDKER, AN .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (06) :1300-1304
[2]   Thin photodiodes for a scintillator-silicon well detector [J].
Allier, CP ;
Hollander, RW ;
Sarro, PM ;
van Eijk, CWE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) :1948-1951
[3]   SATELLITE ANOMALIES FROM GALACTIC COSMIC-RAYS [J].
BINDER, D ;
SMITH, EC ;
HOLMAN, AB .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1975, 22 (06) :2675-2680
[4]   MICRODOSIMETRIC INVESTIGATIONS ON COLLIMATED FAST-NEUTRON BEAMS FOR RADIATION-THERAPY .2. THE PROBLEM OF RADIATION QUALITY AND RBE [J].
BOOZ, J ;
FIDORRA, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (01) :43-56
[5]   Tissue equivalent detector data obtained recently on mir space station. Comparison with solid state detector data [J].
BottollierDepois, JF ;
LebaronJacobs, L ;
Siegrist, M ;
Duvivier, E ;
Almarcha, B ;
Dachev, TP ;
Semkova, JV ;
Matviichuk, YN ;
Koleva, RT ;
Tomov, BT ;
Baynov, PT ;
Petrov, VM ;
Shurshakov, VV ;
Bengin, V ;
Koslova, SB .
LIFE SCIENCES: SPACE AND MARS RECENT RESULTS, 1996, 18 (12) :171-174
[6]  
BRABY LA, 1994, RADIAT PROT DOSIM, V52, P423
[7]  
BRADFORD JN, 1982, P 8 S MICR JUL
[8]  
BRADLEY P, 2000, DEV NOVEL SILICON MI, P1
[9]   Charge collection and radiation hardness of a SOI microdosimeter for medical and space applications [J].
Bradley, PD ;
Rosenfeld, AB ;
Lee, KK ;
Jamieson, DN ;
Heiser, G ;
Satoh, S .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (06) :2700-2710
[10]   Tissue equivalence correction for silicon microdosimetry detectors in boron neutron capture therapy [J].
Bradley, PD ;
Rosenfeld, AB .
MEDICAL PHYSICS, 1998, 25 (11) :2220-2225