Combined multiplanar optical coherence tomography and confocal scanning ophthalmoscopy

被引:71
作者
Podoleanu, AG [1 ]
Dobre, GM
Cucu, RG
Rosen, R
Garcia, P
Nieto, J
Will, D
Gentile, R
Muldoon, T
Walsh, J
Yannuzzi, LA
Fisher, Y
Orlock, D
Weitz, R
Rogers, JA
Dunne, S
Boxer, A
机构
[1] Univ Kent, Sch Phys Sci, Appl Opt Grp, Canterbury CT2 7NZ, Kent, England
[2] New York Eye & Ear Infirm, Adv Retinal Imaging Ctr, New York, NY 10003 USA
[3] Lu Esther T Mertz Retinal Res Ctr, New York, NY USA
[4] Ophthalm Technol Inc, Toronto, ON, Canada
基金
英国工程与自然科学研究理事会;
关键词
optical coherence tomograhy; confocal; retinal imaging; depth-resolved imaging;
D O I
10.1117/1.1627778
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We demonstrate the clinical application of a multiplanar imaging system that simultaneously acquires en face (C-scan) optical coherence tomography (OCT) and the corresponding confocal ophthalmoscopic images, along with cross-sectional (B-scan) OCT at specifiable locations on the confocal image. The advantages of the simultaneous OCT and confocal acquisition as well as the challenges of interpreting the C-scan OCT images are discussed. Variations in tissue inclination with respect to the coherence wave surface alter the sampling of structures within the depth of the retina, producing novel slice orientations that are often challenging to interpret. We have evaluated for the first time the utility of C-scan OCT for a variety of pathologies, including melanocytoma, diabetic retinopathy, choroidal neovascular membrane, and macular pucker. Several remarkable new aspects of clinical anatomy were revealed using this new technique. The versatility of selective capture of C-scan OCT images and B-scan OCT images at precise points on the confocal image affords the clinician a more complete and interactive tool for 3-D imaging of retinal pathology. (C) 2004 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:86 / 93
页数:8
相关论文
共 30 条
[21]   En-face coherence imaging using galvanometer scanner modulation [J].
Podoleanu, AG ;
Dobre, GM ;
Jackson, DA .
OPTICS LETTERS, 1998, 23 (03) :147-149
[22]   Coherence imaging by use of a Newton rings sampling function [J].
Podoleanu, AG ;
Dobre, GM ;
Webb, DJ ;
Jackson, DA .
OPTICS LETTERS, 1996, 21 (21) :1789-1791
[23]   Three dimensional OCT images from retina and skin [J].
Podoleanu, AG ;
Rogers, JA ;
Jackson, DA .
OPTICS EXPRESS, 2000, 7 (09) :292-298
[24]   Combined optical coherence tomograph and scanning laser ophthalmoscope [J].
Podoleanu, AG ;
Jackson, DA .
ELECTRONICS LETTERS, 1998, 34 (11) :1088-1090
[25]   Noise analysis of a combined optical coherence tomograph and a confocal scanning ophthalmoscope [J].
Podoleanu, AG ;
Jackson, DA .
APPLIED OPTICS, 1999, 38 (10) :2116-2127
[26]   Topography and volume measurements of the optic nerve using en-face optical coherence tomography [J].
Rogers, JA ;
Podoleanu, AG ;
Dobre, GM ;
Jackson, DA ;
Fitzke, FW .
OPTICS EXPRESS, 2001, 9 (10) :533-545
[27]   Adaptive optics scanning laser ophthalmoscopy [J].
Roorda, A ;
Romero-Borja, F ;
Donnelly, WJ ;
Queener, H ;
Hebert, TJ ;
Campbell, MCW .
OPTICS EXPRESS, 2002, 10 (09) :405-412
[28]   CONFOCAL SCANNING LASER OPHTHALMOSCOPE [J].
WEBB, RH ;
HUGHES, GW ;
DELORI, FC .
APPLIED OPTICS, 1987, 26 (08) :1492-1499
[29]   CONFOCAL IMAGING OF THE FUNDUS USING A SCANNING LASER OPHTHALMOSCOPE [J].
WOON, WH ;
FITZKE, FW ;
BIRD, AC ;
MARSHALL, J .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1992, 76 (08) :470-474
[30]   DETECTION OF DIABETIC-RETINOPATHY BY SCANNING LASER OPHTHALMOSCOPY [J].
WYKES, WN ;