Selective potentiometric determination of uric acid with uricase immobilized on ZnO nanowires

被引:96
作者
Ali, Syed M. Usman [1 ]
Alvi, N. H. [1 ]
Ibupoto, Zafar [1 ]
Nur, Omer [1 ]
Willander, Magnus [1 ]
Danielsson, Bengt [2 ]
机构
[1] Linkoping Univ, Dept Sci & Technol, Phys Elect & Nanotechnol Div, Phys Elect Grp, SE-60174 Norrkoping, Sweden
[2] Acromed Invest AB, SE-22643 Lund, Sweden
关键词
ZnO nanowires; Potentiometric nanosensor; Uricase; Uric acid; Nafion (R); Membrane; Electrochemical nanodevices; GLUCOSE-OXIDASE; IN-VIVO; BIOSENSOR; ENZYME; ELECTRODE; SENSORS; SYSTEM; MANAGEMENT; FILMS; GOUT;
D O I
10.1016/j.snb.2010.12.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a potentiometric uric acid biosensor was fabricated by immobilization of uricase onto zinc oxide (ZnO) nanowires. Zinc oxide nanowires with 80-150 nm in diameter and 900 nm to 1.5 mu m in lengths were grown on the surface of a gold coated flexible plastic substrate. Uricase was electrostatically immobilized on the surface of well aligned ZnO nanowires resulting in a sensitive, selective, stable and reproducible uric acid biosensor. The potentiometric response of the ZnO sensor vs Ag/AgCl reference electrode was found to be linear over a relatively wide logarithmic concentration range (1-650 mu M) suitable for human blood serum. By applying a Nafion (R) membrane on the sensor the linear range could be extended to 1-1000 mu M at the expense of an increased response time from 6.25 s to less than 9 s. On the other hand the membrane increased the sensor durability considerably. The sensor response was unaffected by normal concentrations of common interferents such as ascorbic acid, glucose, and urea. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:241 / 247
页数:7
相关论文
共 39 条
[1]   A biosensor based on urate oxidase-peroxidase coupled enzyme system for uric acid determination in urine [J].
Akyilmaz, E ;
Sezgintürk, MK ;
Dinçkaya, E .
TALANTA, 2003, 61 (02) :73-79
[2]   Zinc oxide nanorods grown on two-dimensional macroporous periodic structures and plane Si as a pH sensor [J].
Al-Hilli, Safaa M. ;
Al-Mofarji, R. T. ;
Klason, P. ;
Willander, M. ;
Gutman, N. ;
Sa'ar, A. .
JOURNAL OF APPLIED PHYSICS, 2008, 103 (01)
[3]   Uric acid: role in cardiovascular disease and effects of losartan [J].
Alderman, M ;
Aiyer, KJV .
CURRENT MEDICAL RESEARCH AND OPINION, 2004, 20 (03) :369-379
[4]   A fast and sensitive potentiometric glucose microsensor based on glucose oxidase coated ZnO nanowires grown on a thin silver wire [J].
Ali, Syed M. Usman ;
Nur, O. ;
Willander, M. ;
Danielsson, B. .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 145 (02) :869-874
[5]   Glucose Detection With a Commercial MOSFET Using a ZnO Nanowires Extended Gate [J].
Ali, Syed Muhammad Usman ;
Nur, Omer ;
Willander, Magnus ;
Danielsson, Bengt .
IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2009, 8 (06) :678-683
[6]   Functionalised ZnO-nanorod-based selective electrochemical sensor for intracellular glucose [J].
Asif, Muhammad H. ;
Ali, Syed M. Usman ;
Nur, Omer ;
Willander, Magnus ;
Brannmark, Cecilia ;
Stralfors, Peter ;
Englund, Ulrika H. ;
Elinder, Fredrik ;
Danielsson, Bengt .
BIOSENSORS & BIOELECTRONICS, 2010, 25 (10) :2205-2211
[7]   An Amperomertic Uric Acid Biosensor Based on Immobilization of Uricase onto Polyaniline-multiwalled Carbon Nanotube Composite Film [J].
Bhambi, Manu ;
Sumana, G. ;
Malhotra, B. D. ;
Pundir, C. S. .
ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2010, 38 (04) :178-185
[8]   FIELD-EFFECT TRANSISTOR SENSITIVE TO PENICILLIN [J].
CARAS, S ;
JANATA, J .
ANALYTICAL CHEMISTRY, 1980, 52 (12) :1935-1937
[9]   Nanotechnology and biosensors [J].
Chen, JR ;
Miao, YQ ;
He, NY ;
Wu, XH ;
Li, SJ .
BIOTECHNOLOGY ADVANCES, 2004, 22 (07) :505-518
[10]   Disposable amperometric glucose sensor electrode with enzyme-immobilized nitrocellulose strip [J].
Cui, G ;
Yoo, JH ;
Woo, BW ;
Kim, SS ;
Cha, GS ;
Nam, H .
TALANTA, 2001, 54 (06) :1105-1111