Validation of bone mass and body composition measurements in small subjects with pencil beam dual energy X-ray absorptiometry

被引:17
作者
Koo, WWK
Hammami, M
Hockman, EM
机构
[1] Wayne State Univ, Dept Pediat Obstet & Gynecol, Detroit, MI 48202 USA
[2] Wayne State Univ, Dept Comp & Informat Technol, Detroit, MI 48202 USA
关键词
pig; ash; calcium; fat; lean tissue; bone;
D O I
10.1080/07315724.2004.10719346
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 [营养与食品卫生学];
摘要
Objective: To validate the most widely reported dual energy X-ray absorptiometry (DXA) technique for the measurement of bone mass and body composition in human infants with a Piglet model, Methods: Duplicate scans were obtained in 13 piglets (1950g to 21100g) using a whole body densitometer (Hologic QDR 2000 plus, Hologic Inc., Waltham, MA) operated in the pencil-beam mode on a two platform (aluminum platform overlying a foam table pad) system. DXA measurements that included total weight, bone mineral content, fat and lean mass were compared with carcass weight and chemical analysis for ash and calcium content, fat and lean mass. Results: Measurements from duplicate DXA scans were nearly perfectly correlated (r = 0.98 to 1.00). DXA measurements were strongly predictive of scale weight and chemical composition for all piglets (adjusted r(2) = 0.93 to 1.00, intraclass reliability coefficients = 0.943 to 0.999, p < 0.001 for all comparisons) although DXA bone mineral content consistently underestimated carcass ash and calcium content. Measured values from heavier piglets were not significantly different from values predicted from the lighter piglets' data. Slopes from regression based on lighter versus heavier piglets were not significantly different except for the bone mineral content with carcass ash or calcium content. Conclusion: Our study validated the use of pencil beam DXA and its ability to determine relative changes in bone mass and body composition measurements over a much greater range of body weight than previous reports although its use as a direct indicator of nutrient requirement may be limited.
引用
收藏
页码:79 / 84
页数:6
相关论文
共 29 条
[1]
Clinical applications of body composition measurements using DXA [J].
Albanese, CV ;
Diessel, E ;
Genant, HK .
JOURNAL OF CLINICAL DENSITOMETRY, 2003, 6 (02) :75-85
[2]
*AOSC, 1995, ASS OFF AN CHEM OFF, P7
[3]
VALIDATION AND APPLICATION OF DUAL-ENERGY X-RAY ABSORPTIOMETRY TO MEASURE BONE MASS AND BODY-COMPOSITION IN SMALL INFANTS [J].
BRUNTON, JA ;
BAYLEY, HS ;
ATKINSON, SA .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 58 (06) :839-845
[4]
Body composition during the first 2 years of life: An updated reference [J].
Butte, NF ;
Hopkinson, JM ;
Wong, WW ;
Smith, EO ;
Ellis, KJ .
PEDIATRIC RESEARCH, 2000, 47 (05) :578-585
[5]
Infant feeding mode affects early growth and body composition [J].
Butte, NF ;
Wong, WW ;
Hopkinson, JM ;
Smith, EO ;
Ellis, KJ .
PEDIATRICS, 2000, 106 (06) :1355-1366
[6]
Fan beam dual energy X-ray absorptiometry body composition measurements in piglets [J].
Chauhan, S ;
Koo, WWK ;
Hammami, M ;
Hockman, EM .
JOURNAL OF THE AMERICAN COLLEGE OF NUTRITION, 2003, 22 (05) :408-414
[7]
Diet and bone mineral content at term in premature infants [J].
Faerk, J ;
Petersen, S ;
Peitersen, B ;
Michaelsen, KF .
PEDIATRIC RESEARCH, 2000, 47 (01) :148-156
[8]
FOLCH J, 1957, J BIOL CHEM, V226, P497
[9]
Neonatal body composition:: Dual-energy X-ray absorptiometry, magnetic resonance imaging, and three-dimensional chemical shift imaging versus chemical analysis in piglets [J].
Fusch, C ;
Slotboom, J ;
Fuehrer, U ;
Schumacher, R ;
Keisker, A ;
Zimmermann, W ;
Moessinger, A ;
Boesch, C ;
Blum, J .
PEDIATRIC RESEARCH, 1999, 46 (04) :465-473
[10]
ACCURATE ASSESSMENT OF PRECISION ERRORS - HOW TO MEASURE THE REPRODUCIBILITY OF BONE DENSITOMETRY TECHNIQUES [J].
GLUER, CC ;
BLAKE, G ;
LU, Y ;
BLUNT, BA ;
JERGAS, M ;
GENANT, HK .
OSTEOPOROSIS INTERNATIONAL, 1995, 5 (04) :262-270