Micromachine-based multi-channel flow cytometers for cell/particle counting and sorting

被引:43
作者
Lee, GB [1 ]
Lin, CH
Chang, SC
机构
[1] Natl Cheng Kung Univ, Dept Engn Sci, Tainan 701, Taiwan
[2] Natl Sun Yat Sen Univ, Dept Mech & Electromech Engn, Kaohsiung 804, Taiwan
关键词
D O I
10.1088/0960-1317/15/3/004
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper reports a new micromachine-based flow cytometer capable of parallel processing of cell/particle counting and sorting using microfluidic technologies. Hydrodynamic focusing of multiple sample streams is first achieved by using a new layout of sheath flow channels coming from one single inlet port. Thus only one syringe pump is required during the operation. The flow rate of each sheath flow could be much more stable and uniform with this approach. The images of the focused multiple samples are then recorded downstream utilizing a high-speed digital CCD camera. The digital image processing technique is then used to count the number of the cells/particles. Theoretical models based on a 'flow-rate-ratio' method are used to predict the width of the multiple focused streams, which could be incorporated with a digital image processing system for cell/particle counting. Experimental data are found to be highly consistent with the theoretical results. Experimental data show that the developed device can successfully detect the number of cells/particles in two parallel sample streams and the velocities of the cells/particles in each cell line as well. Low counting error and high counting reliability are also verified by counting a mixture of polystyrene beads with different sizes. In addition, human red blood cells are used for the cell-counting test. Subsequently, cell/particle sorting could be achieved using dielectrophoretic (DEP) forces generated by built-in micro-electrodes downstream. Cell/particle sorting has been performed successfully using the DEP electrodes. The development of the multi-channel micro-flow cytometer could be crucial for the advancement of the cell-counting device.
引用
收藏
页码:447 / 454
页数:8
相关论文
共 37 条
[1]   An investigation of liquid carryover and sample residual for a high-throughput flow cytometer sample delivery system [J].
Bartsch, JW ;
Tran, HD ;
Waller, A ;
Mammoli, AA ;
Buranda, T ;
Sklar, LA ;
Edwards, BS .
ANALYTICAL CHEMISTRY, 2004, 76 (13) :3810-3817
[2]  
Brown M, 2000, CLIN CHEM, V46, P1221
[3]   NEW FLOW CYTOMETRIC CAPABILITIES AT THE NATIONAL FLOW-CYTOMETRY RESOURCE [J].
CRAM, LS ;
MARTIN, JC ;
STEINKAMP, JA ;
YOSHIDA, TM ;
BUICAN, TN ;
MARRONE, BL ;
JETT, JH ;
SALZMAN, G ;
SKLAR, L .
PROCEEDINGS OF THE IEEE, 1992, 80 (06) :912-917
[4]   Optical particle detection integrated in a dielectrophoretic lab-on-a-chip [J].
Cui, L ;
Zhang, T ;
Morgan, H .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2002, 12 (01) :7-12
[5]   FLOW-CYTOMETRY IN TOXICITY ANALYSIS [J].
DALLAS, CE ;
EVANS, DL .
NATURE, 1990, 345 (6275) :557-558
[6]   Microdevices for manipulation and accumulation of micro- and nanoparticles by dielectrophoresis [J].
Dürr, M ;
Kentsch, J ;
Müller, T ;
Schnelle, T ;
Stelzle, M .
ELECTROPHORESIS, 2003, 24 (04) :722-731
[7]   A microfabricated fluorescence-activated cell sorter [J].
Fu, AY ;
Spence, C ;
Scherer, A ;
Arnold, FH ;
Quake, SR .
NATURE BIOTECHNOLOGY, 1999, 17 (11) :1109-1111
[8]   Manipulation of microparticles using new modes of traveling-wave-dielectrophoretic forces: Numerical simulation and experiments [J].
Fu, LM ;
Lee, GB ;
Lin, YH ;
Yang, RJ .
IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2004, 9 (02) :377-383
[9]   Flow cytometry in transfusion medicine: Development, strategies and applications [J].
Greve, B ;
Valet, G ;
Humpe, A ;
Tonn, T ;
Cassens, U .
TRANSFUSION MEDICINE AND HEMOTHERAPY, 2004, 31 (03) :152-161
[10]   A flow cytometry method for rapid detection and enumeration of total bacteria in milk [J].
Gunasekera, TS ;
Attfield, PV ;
Veal, DA .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2000, 66 (03) :1228-1232