Amperometric cholesterol biosensor based on immobilized cholesterol esterase and cholesterol oxidase on conducting polypyrrole films

被引:123
作者
Singh, S [1 ]
Chaubey, A [1 ]
Malhotra, BD [1 ]
机构
[1] Natl Phys Lab, Biomol Elect & Conducting Polymer Res Grp, New Delhi 110012, India
关键词
lmmobilization; biosensor; cholesterol esterase; cholesterol oxidase; polypyrrole;
D O I
10.1016/j.aca.2003.09.064
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fabrication of an amperometric cholesterol biosensor by co-immobilization of cholesterol esterase (ChEt) and cholesterol oxidase (ChOx) onto conducting polypyrrole (PPY) films using electrochemical entrapment technique is described. Electrochemical polymerization was carried out using a two-electrode cell configuration at 0.8 V. Characterization of resulting amperometric biosensor for the estimation of cholesterol has been experimentally determined in terms of linear response range, optimum pH, applied potential, temperature, and shelf-life. These PPY/ChEt/ChOx electrodes can be used for cholesterol ester estimation from 1 to 8 mM and have shelf-life of about 4 weeks at 4degreesC during which about 15 estimations of cholesterol ester could be made. The sensitivity of PPY/ChEt/ChOx electrode has been found to be 0.15 muA/mM and the apparent K. value for this electrode is 9.8 mM. Conductivity of the polymer films found to be about 3 x 10(-3) S/cm. (C) 2003 Published by Elsevier B.V.
引用
收藏
页码:229 / 234
页数:6
相关论文
共 37 条
[1]  
ALLAIN CC, 1974, CLIN CHEM, V20, P470
[2]  
[Anonymous], 1991, BIOSENSORS
[3]   THE ELECTRODEPOSITION OF POLYPYRROLE FILMS FROM AQUEOUS-SOLUTIONS [J].
ASAVAPIRIYANONT, S ;
CHANDLER, GK ;
GUNAWARDENA, GA ;
PLETCHER, D .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 177 (1-2) :229-244
[4]  
Bowers L D, 1976, Anal Chem, V48, p544A
[5]   Polypyrrole-hydrogel composites for the construction of clinically important biosensors [J].
Brahim, S ;
Narinesingh, D ;
Guiseppi-Elie, A .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (1-2) :53-59
[6]   Cholesterol lowering in atherosclerosis [J].
Brown, WV .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (4B) :29H-32H
[7]   Amperometric determination of cholesterol in serum with use of a renewable surface peroxidase electrode [J].
Charpentier, L ;
ElMurr, N .
ANALYTICA CHIMICA ACTA, 1995, 318 (01) :89-93
[8]  
Chaubey A., 2002, HDB POLYM ELECT, P297
[9]   ELECTROCHEMICAL RESPONSE OF AN ENZYME-LOADED POLYANILINE FILM [J].
COOPER, JC ;
HALL, EAH .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (07) :473-485
[10]   USE OF POLYMER-FILMS IN AMPEROMETRIC BIOSENSORS [J].
EMR, SA ;
YACYNYCH, AM .
ELECTROANALYSIS, 1995, 7 (10) :913-923