Estimation of lactate in meat extracts by screen-printed sensors

被引:18
作者
Hart, AL [1 ]
Matthews, C [1 ]
Collier, WA [1 ]
机构
[1] Ag Res Grasslands, Palmerston North, New Zealand
关键词
lactate; meat; screen-printing; stability; PVC;
D O I
10.1016/S0003-2670(99)00027-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Various facets of sensor technology: platinum dispersed on carbon, a second "blank" working electrode, polymer matrices for enzymes and diffusion-limiting membranes, were integrated using screen-printing to produce lactate sensors. The enzyme was lactate oxidase. The polymer matrices were hydroxyethyl cellulose, GafQuat/lactitol and hydroxyethyl cellulose/polyethyleneimine. The outer membrane was of known composition: polyvinyl chloride co-polymer/cellulose acetate butyrate. When the sensors were mounted in a flow injection analyser, estimates were obtained of the lactate concentration in simple buffer extracts of cattle meat. The most accurate estimates were obtained from sensors in which the enzyme was embedded in a matrix of GafQuat/lactitol or hydroxyethyl cellulose/polyethyleneimine. The currents generated by the enzyme in the matrices containing GafQuat or polyethyleneimine were higher than when hydroxyethyl cellulose alone was used as a matrix. The activity of the sensors under dry storage (over silica gel at 25 degrees C) varied over eight months, but remained at a functional level. Every step in these relatively simple sensors was achieved by screen-printing; the use of a "blank" working electrode avoided the necessity of additional layers or membranes to reject interferents and the flow injection analyser provided a constant hydrodynamic environment for sensor function. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 29 条
[1]   THICK-FILM HYBRID PH SENSORS [J].
BELFORD, RE ;
OWEN, AE ;
KELLY, RG .
SENSORS AND ACTUATORS, 1987, 11 (04) :387-398
[2]   Poly(vinyl chloride), polysulfone and sulfonated polyether-ether sulfone composite membranes for glucose and hydrogen peroxide perm-selectivity in amperometric biosensors [J].
Benmakroha, Y ;
Christie, I ;
Desai, M ;
Vadgama, P .
ANALYST, 1996, 121 (04) :521-526
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   PLASTICIZED POLY(VINYL CHLORIDE) AS A PERMSELECTIVE BARRIER MEMBRANE FOR HIGH-SELECTIVITY AMPEROMETRIC SENSORS AND BIOSENSORS [J].
CHRISTIE, IM ;
TRELOAR, PH ;
VADGAMA, P .
ANALYTICA CHIMICA ACTA, 1992, 269 (01) :65-73
[5]   Estimation of soluble L-lactate in dairy products using screen-printed sensors in a flow injection analyser [J].
Collier, WA ;
Lovejoy, P ;
Hart, AL .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (02) :219-225
[6]   Measurement of soluble L-lactate in dairy products using screen-printed sensors in batch mode [J].
Collier, WA ;
Janssen, D ;
Hart, AL .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (10) :1041-1049
[7]  
Davis G, 1998, CHEM ANAL SERIES MON, V148, P47
[8]   Novel instrumentation for real-time monitoring using miniaturized flow systems with integrated biosensors [J].
Freaney, R ;
McShane, A ;
Keaveny, TV ;
McKenna, M ;
Rabenstein, K ;
Scheller, FW ;
Pfeiffer, D ;
Urban, G ;
Moser, I ;
Jobst, G ;
Manz, A ;
Verpoorte, E ;
Widmer, MW ;
Diamond, D ;
Dempsey, E ;
deViteri, FJS ;
Smyth, M .
ANNALS OF CLINICAL BIOCHEMISTRY, 1997, 34 :291-302
[9]   SCREEN PRINTING - A TECHNOLOGY FOR THE BATCH FABRICATION OF INTEGRATED CHEMICAL-SENSOR ARRAYS [J].
GOLDBERG, HD ;
BROWN, RB ;
LIU, DP ;
MEYERHOFF, ME .
SENSORS AND ACTUATORS B-CHEMICAL, 1994, 21 (03) :171-183
[10]   The response of screen-printed enzyme electrodes containing cholinesterases to organo-phosphates in solution and from commercial formulations [J].
Hart, AL ;
Collier, WA ;
Janssen, D .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (07) :645-654