Estimation of lactate in meat extracts by screen-printed sensors

被引:18
作者
Hart, AL [1 ]
Matthews, C [1 ]
Collier, WA [1 ]
机构
[1] Ag Res Grasslands, Palmerston North, New Zealand
关键词
lactate; meat; screen-printing; stability; PVC;
D O I
10.1016/S0003-2670(99)00027-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Various facets of sensor technology: platinum dispersed on carbon, a second "blank" working electrode, polymer matrices for enzymes and diffusion-limiting membranes, were integrated using screen-printing to produce lactate sensors. The enzyme was lactate oxidase. The polymer matrices were hydroxyethyl cellulose, GafQuat/lactitol and hydroxyethyl cellulose/polyethyleneimine. The outer membrane was of known composition: polyvinyl chloride co-polymer/cellulose acetate butyrate. When the sensors were mounted in a flow injection analyser, estimates were obtained of the lactate concentration in simple buffer extracts of cattle meat. The most accurate estimates were obtained from sensors in which the enzyme was embedded in a matrix of GafQuat/lactitol or hydroxyethyl cellulose/polyethyleneimine. The currents generated by the enzyme in the matrices containing GafQuat or polyethyleneimine were higher than when hydroxyethyl cellulose alone was used as a matrix. The activity of the sensors under dry storage (over silica gel at 25 degrees C) varied over eight months, but remained at a functional level. Every step in these relatively simple sensors was achieved by screen-printing; the use of a "blank" working electrode avoided the necessity of additional layers or membranes to reject interferents and the flow injection analyser provided a constant hydrodynamic environment for sensor function. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 29 条
[21]  
PACE SJ, 1986, P 2 INT M CHEM SENS, P6
[22]   Thick-film multichannel biosensors for simultaneous amperometric and potentiometric measurements [J].
Silber, A ;
Bisenberger, M ;
Brauchle, C ;
Hampp, N .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 30 (02) :127-132
[23]   Evaluation of a new disposable screen-printed sensor strip for the measurement of NADH and its modification to produce a lactate biosensor employing microliter volumes [J].
Sprules, SD ;
Hart, JP ;
Pittson, R ;
Wring, SA .
ELECTROANALYSIS, 1996, 8 (06) :539-543
[24]   MICROFABRICATED PHENOL BIOSENSORS BASED ON SCREEN PRINTING OF TYROSINASE CONTAINING CARBON INK [J].
WANG, J ;
CHEN, QA .
ANALYTICAL LETTERS, 1995, 28 (07) :1131-1142
[25]   Pulsed flow chemistry. A new approach to the generation of concentration profiles in flow analysis [J].
Wang, XD ;
Cardwell, TJ ;
Cattrall, RW ;
Jenkins, GE .
ANALYTICAL COMMUNICATIONS, 1998, 35 (03) :97-101
[26]  
WEIL MH, 1986, CLIN CHEM, V32, P2175
[27]   Thick-film sensors: Past, present and future [J].
White, NM ;
Turner, JD .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1997, 8 (01) :1-20
[28]   Development of a mass-producible glucose biosensor and flow-injection analysis system suitable for on-line monitoring during fermentations [J].
White, SF ;
Tothill, IE ;
Newman, JD ;
Turner, APF .
ANALYTICA CHIMICA ACTA, 1996, 321 (2-3) :165-172
[29]   CHEMICALLY MODIFIED, CARBON-BASED ELECTRODES AND THEIR APPLICATION AS ELECTROCHEMICAL SENSORS FOR THE ANALYSIS OF BIOLOGICALLY IMPORTANT COMPOUNDS - A REVIEW [J].
WRING, SA ;
HART, JP .
ANALYST, 1992, 117 (08) :1215-1229