Serial Assessment of Coronary Artery Response to Paclitaxel-Eluting Stents Using Optical Coherence Tomography

被引:23
作者
Guagliumi, Giulio [1 ]
Bezerra, Hiram G. [2 ]
Sirbu, Vasile
Ikejima, Hideyuki
Musumeci, Giuseppe
Biondi-Zoccai, Giuseppe [3 ]
Lortkipanidze, Nikoloz
Fiocca, Luigi
Capodanno, Davide [4 ,5 ]
Wang, Wei [2 ]
Tahara, Satoko [2 ]
Vassileva, Angelina
Matiashvili, Aleksandre
Valsecchi, Orazio
Costa, Marco A. [2 ]
机构
[1] Osped Riuniti Bergamo, Div Cardiol, Cardiovasc Dept, I-24128 Bergamo, Italy
[2] Case Western Reserve Univ, Univ Hosp Case Med Ctr, Cleveland, OH 44106 USA
[3] Univ Modena & Reggio Emilia, Div Cardiol, Modena, Italy
[4] Univ Catania, Catania, Italy
[5] Ferrarotto Hosp, Dept Cardiol, Catania, Italy
关键词
percutaneous coronary intervention; drug-eluting stent; optical coherence tomography; malapposition; stent coverage; ELEVATION MYOCARDIAL-INFARCTION; VESSEL WALL RESPONSE; BARE-METAL STENTS; INTRAVASCULAR ULTRASOUND; VASCULAR-RESPONSE; STRUT COVERAGE; FOLLOW-UP; SIROLIMUS; IMPLANTATION; THROMBOSIS;
D O I
10.1161/CIRCINTERVENTIONS.111.965582
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The paucity of longitudinal, serial high-resolution imaging studies has limited our understanding of in vivo arterial response to drug-eluting stents. We sought to investigate the human coronary response to paclitaxel-eluting stent implantation, using serial optical coherence tomography assessments. Methods and Results-Thirty patients with at least 2 significant coronary lesions in different vessels were treated with a paclitaxel-eluting stent. The most severe stenosis (lesion A) was treated at the initial procedure, and the second target vessel (lesion B) was stented 3 months later. Optical coherence tomography was performed at baseline, 3-, and 9-month follow-up for lesions A and baseline and 6 months for lesions B. Prespecified end points were percent of uncovered and malapposed struts over time. In lesions A, uncovered struts were 3.77 +/- 4.94% and 3.02 +/- 4.35% at 3 versus 9 months (P = NS). Malapposed struts were 3.55 +/- 5.16% at post-procedure, 1.51 +/- 3.52% at 3 months, and 0.60 +/- 1.82% at 9 months (P < 0.05, at 3 versus 9 months). Strut-level neointimal thickness was 0.19 +/- 0.09 mm and 0.20 +/- 0.11 mm (P = NS) over time. Newly acquired malapposition was detected in 10.4% and 3.3% of 2.5-mm segments at 3- and 9-month follow-up. In lesions B, uncovered struts were 2.91 +/- 5.47% at 6-months. Malapposed struts were 4.94 +/- 6.70% post-procedure and 1.01 +/- 3.11% at 6 months (P<0.01), with 0.19 +/- 0.09-mm neointimal thickness at follow-up. Conclusions-Optical coherence tomography imaging suggested the first 3 months to be the period with most biological activity after paclitaxel-eluting stent implantation, when the proliferative reaction mainly occurs and malapposition resolves. A less active, yet continuous, dynamic arterial response, with resolution and development of malapposition, occurs through 9 months post-treatment.
引用
收藏
页码:30 / 38
页数:9
相关论文
共 24 条
[1]   Intracoronary Optical Coherence Tomography: A Comprehensive Review Clinical and Research Applications [J].
Bezerra, Hiram G. ;
Costa, Marco A. ;
Guagliumi, Giulio ;
Rollins, Andrew M. ;
Simon, Daniel I. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (11) :1035-1046
[2]   Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation [J].
Cook, Stephane ;
Wenaweser, Peter ;
Togni, Mario ;
Billinger, Michael ;
Morger, Cyrill ;
Seiler, Christian ;
Vogel, Rolf ;
Hess, Otto ;
Meier, Bernhard ;
Windecker, Stephan .
CIRCULATION, 2007, 115 (18) :2426-2434
[3]   Molecular basis of restenosis and drug-eluting stents [J].
Costa, MA ;
Simon, DI .
CIRCULATION, 2005, 111 (17) :2257-2273
[4]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351
[5]   Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice:: data from a large two-institutional cohort study [J].
Daemen, Joost ;
Wenaweser, Peter ;
Tsuchida, Keiichi ;
Abrecht, Linda ;
Sophia, Vaina ;
Morger, Cyrill ;
Kukreja, Neville ;
Jueni, Peter ;
Sianos, Georgios ;
Hellige, Gerrit ;
van Domburg, Ron T. ;
Hess, Otto M. ;
Boersma, Eric ;
Meier, Bernhard ;
Windecker, Stephan ;
Serruys, Patrick W. .
LANCET, 2007, 369 (9562) :667-678
[6]   Pathological correlates of late drug-eluting stent thrombosis - Strut coverage as a marker of endothelialization [J].
Finn, Aloke V. ;
Joner, Michael ;
Nakazawa, Gaku ;
Kolodgie, Frank ;
Newell, John ;
John, Mike C. ;
Gold, Herman K. ;
Virmani, Renu .
CIRCULATION, 2007, 115 (18) :2435-2441
[7]   Optical coherence tomography assessment of the acute effects of stent implantation on the vessel wall: a systematic quantitative approach [J].
Gonzalo, N. ;
Serruys, P. W. ;
Okamura, T. ;
Shen, Z. J. ;
Onuma, Y. ;
Garcia-Garcia, H. M. ;
Sarno, G. ;
Schultz, C. ;
van Geuns, R. J. ;
Ligthart, J. ;
Regar, E. .
HEART, 2009, 95 (23) :1913-1919
[8]   Incomplete Stent Apposition and Delayed Tissue Coverage Are More Frequent in Drug-Eluting Stents Implanted During Primary Percutaneous Coronary Intervention for ST-Segment Elevation Myocardial Infarction Than in Drug-Eluting Stents Implanted for Stable/Unstable Angina Insights From Optical Coherence Tomography [J].
Gonzalo, Nieves ;
Barlis, Peter ;
Serruys, Patrick W. ;
Garcia-Garcia, Hector M. ;
Onuma, Yoshinobu ;
Ligthart, Jurgen ;
Regar, Evelyn .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (05) :445-452
[9]   Strut Coverage and Late Malapposition With Paclitaxel-Eluting Stents Compared With Bare Metal Stents in Acute Myocardial Infarction Optical Coherence Tomography Substudy of the Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) Trial [J].
Guagliumi, Giulio ;
Costa, Marco A. ;
Sirbu, Vasile ;
Musumeci, Giuseppe ;
Bezerra, Hiram G. ;
Suzuki, Nobuaki ;
Matiashvili, Aleksandre ;
Lortkipanidze, Nikoloz ;
Mihalcsik, Laurian ;
Trivisonno, Antonio ;
Valsecchi, Orazio ;
Mintz, Gary S. ;
Dressler, Ovidiu ;
Parise, Helen ;
Maehara, Akiko ;
Cristea, Ecaterina ;
Lansky, Alexandra J. ;
Mehran, Roxana ;
Stone, Gregg W. .
CIRCULATION, 2011, 123 (03) :274-281
[10]   Strut Coverage and Vessel Wall Response to a New-Generation Paclitaxel-Eluting Stent With an Ultrathin Biodegradable Abluminal Polymer Optical Coherence Tomography Drug-Eluting Stent Investigation (OCTDESI) [J].
Guagliumi, Giulio ;
Sirbu, Vasile ;
Musumeci, Giuseppe ;
Bezerra, Hiram G. ;
Aprile, Alessandro ;
Kyono, Hiroyuki ;
Fiocca, Luigi ;
Matiashvili, Aleksandre ;
Lortkipanidze, Nikoloz ;
Vassileva, Angelina ;
Popma, Jeffrey J. ;
Allocco, Dominic J. ;
Dawkins, Keith D. ;
Valsecchi, Orazio ;
Costa, Marco A. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (04) :367-U154