Detection of staphylococcal enterotoxin B in spiked food samples

被引:53
作者
Shriver-Lake, LC
Shubin, YS
Ligler, FS
机构
[1] USN, Res Lab, Ctr Biomol Sci & Engn, Washington, DC 20375 USA
[2] Geocenters Inc, Lanham, MD 20706 USA
关键词
D O I
10.4315/0362-028X-66.10.1851
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Contamination of food with infectious agents, intentional or not, is a global concern with far-reaching economic and social impact. Staphylococcal enterotoxins are a major cause of food poisoning, but most methods for the identification of these agents in food require extensive pretreatment or concentration of the sample prior to analysis. The array biosensor was developed as a portable device for the simultaneous analysis of multiple complex samples for multiple targets with minimal sample preparation. In this study, we use an array biosensor to expand and improve on a staphylococcal enterotoxin B (SEB) assay with the ultimate intent of incorporating testing for SEB into a battery of sensitive and convenient assays for food safety validation. In addition to buffer studies, six different types of food samples, including beverages, homogenates of fruit and meat, and carcass washings, were spiked with SEB, incubated for at least 2 h to permit antigen sequestration, and assayed. For all samples, there were differences in fluorescence intensity, but 0.5 ng of SEB per ml could be detected in <20 min with little if any pretreatment and no sample preconcentration.
引用
收藏
页码:1851 / 1856
页数:6
相关论文
共 25 条
[1]   Improved fluoroimmunoassays using the dye Alexa Fluor 647 with the RAPTOR, a fiber optic biosensor [J].
Anderson, GP ;
Nerurkar, NL .
JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 271 (1-2) :17-24
[2]   Staphylococcal enterotoxins [J].
Balaban, N ;
Rasooly, A .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2000, 61 (01) :1-10
[3]   USE OF THIOL-TERMINAL SILANES AND HETEROBIFUNCTIONAL CROSSLINKERS FOR IMMOBILIZATION OF ANTIBODIES ON SILICA SURFACES [J].
BHATIA, SK ;
SHRIVERLAKE, LC ;
PRIOR, KJ ;
GEORGER, JH ;
CALVERT, JM ;
BREDEHORST, R ;
LIGLER, FS .
ANALYTICAL BIOCHEMISTRY, 1989, 178 (02) :408-413
[4]   Automated immunomagnetic separation and microarray detection of E-coli O157:H7 from poultry carcass rinse [J].
Chandler, DP ;
Brown, J ;
Call, DR ;
Wunschel, S ;
Grate, JW ;
Holman, DA ;
Olson, L ;
Stottlemyre, MS ;
Bruckner-Lea, CJ .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2001, 70 (1-2) :143-154
[5]   Rapid detection of Salmonella typhimurium in chicken carcass wash water using an immunoelectrochemical method [J].
Che, YH ;
Li, YB ;
Slavik, M ;
Paul, D .
JOURNAL OF FOOD PROTECTION, 2000, 63 (08) :1043-1048
[6]   Array Biosensor: Optical and Fluidics Systems [J].
Feldstein, Mark J. ;
Golden, Joel P. ;
Rowe, Chris A. ;
MacCraith, Brian D. ;
Ligler, Frances S. .
BIOMEDICAL MICRODEVICES, 1999, 1 (02) :139-153
[7]   Twelve-hour PCR-based method for detection of Salmonella spp. in food [J].
Ferretti, R ;
Mannazzu, I ;
Cocolin, L ;
Comi, G ;
Clementi, F .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2001, 67 (02) :977-978
[8]   Spectral surface plasmon resonance biosensor for detection of staphylococcal enterotoxin B in milk [J].
Homola, J ;
Dostálek, J ;
Chen, SF ;
Rasooly, A ;
Jiang, SY ;
Yee, SS .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2002, 75 (1-2) :61-69
[9]   Rapid and sensitive immunomagnetic-electrochemiluminescent detection of staphyloccocal enterotoxin B [J].
Kijek, TM ;
Rossi, CA ;
Moss, D ;
Parker, RW ;
Henchal, EA .
JOURNAL OF IMMUNOLOGICAL METHODS, 2000, 236 (1-2) :9-17
[10]   Development of a tetramethylrhodamine-labeled probe for a capillary electrophoresis-based competitive immunoassay of staphylococcal enterotoxin B [J].
Lam, MT ;
Boulet, CA ;
Le, XC .
ANALYTICA CHIMICA ACTA, 2002, 457 (01) :21-28