Sol-gel-derived membranes incorporating crown ether neutral carriers by covalent bonding have been designed for durable, nontoxic neutral carrier-type ion sensors by sol-gel processing using tetraethoxysilane, diethoxydimethylsilane, and their corresponding alkoxysilylated neutral carriers. A tetraphenylborate anion was also bound chemically to the neutral carrier-type sol-gel-derived membranes for suppressing anion interference and membrane impedance. Ion-sensitive field effect transistors (ISFETs) based on the sol-gel-derived membranes modified chemically by crown ether derivatives, such as 16-crown-5 and bis(12-crown-4) derivatives, showed high performance, high sensitivity in wide cation activity ranges, short response time, and high electrode durability. Specifically, high ion selectivities of practical use in biological systems were attained in the sodium ISFETs based on the chemically modified bis(12-crown-4), which has been successfully applied to sodium assay in blood sera.
引用
收藏
页码:4309 / 4313
页数:5
相关论文
共 17 条
[1]  
[Anonymous], CHEM PROCESSING ADV
[2]   ALL-SOLID-STATE POLY(VINYL CHLORIDE) MEMBRANE ION-SELECTIVE ELECTRODES WITH POLY(3-OCTYLTHIOPHENE) SOLID INTERNAL CONTACT [J].
BOBACKA, J ;
MCCARRICK, M ;
LEWENSTAM, A ;
IVASKA, A .
ANALYST, 1994, 119 (09) :1985-1991
[3]   COATED-WIRE ELECTRODES CONTAINING POLYMER IMMOBILIZED IONOPHORES BLENDED WITH POLY(VINYL CHLORIDE) [J].
CROSS, GG ;
FYLES, TM ;
SURESH, VV .
TALANTA, 1994, 41 (09) :1589-1595
[4]   THROMBOGENIC PROPERTIES OF UNTREATED AND POLY(ETHYLENE OXIDE)-MODIFIED POLYMERIC MATRICES USEFUL FOR PREPARING INTRAARTERIAL ION-SELECTIVE ELECTRODES [J].
ESPADASTORRE, C ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1995, 67 (18) :3108-3114
[5]   DETERMINATION OF THE EQUIVALENCE POINT IN POTENTIOMETRIC TITRATIONS .2. [J].
GRAN, G .
ANALYST, 1952, 77 (920) :661-671
[6]  
JENNY HB, 1980, MIKROCHIM ACTA, V2, P309
[7]   Sol-gel method for the matrix of chloride-selective membranes doped with tridodecylmethylammonium chloride [J].
Kim, W ;
Chung, S ;
Park, SB ;
Lee, SC ;
Kim, CH ;
Sung, DD .
ANALYTICAL CHEMISTRY, 1997, 69 (01) :95-98
[8]   NEUTRAL-CARRIER-TYPE ION-SENSING MEMBRANES BASED ON SOL-GEL-DERIVED GLASS [J].
KIMURA, K ;
SUNAGAWA, T ;
YOKOYAMA, M .
CHEMISTRY LETTERS, 1995, (10) :967-967
[9]   Applications of sol-gel-derived membranes to neutral carrier-type ion sensitive field-effect transistors [J].
Kimura, K ;
Sunagawa, T ;
Yokoyama, M .
ANALYTICAL CHEMISTRY, 1997, 69 (13) :2379-2383
[10]   UNSYMMETRICAL CALIX[4]ARENE IONOPHORE SILICONE-RUBBER COMPOSITE MEMBRANES FOR HIGH-PERFORMANCE SODIUM ION-SENSITIVE FIELD-EFFECT TRANSISTORS [J].
KIMURA, K ;
MATSUBA, T ;
TSUJIMURA, Y ;
YOKOYAMA, M .
ANALYTICAL CHEMISTRY, 1992, 64 (21) :2508-2511